Powering the MV63 Series
The MV63 features a 1000BASE-TX Ethernet port and requires 802.3at PoE+ minimally for operation. Route the Ethernet cable from an active port on a PoE
switch or injector.
Note: Power over Ethernet supports a maximum cable length of 300 ft (100 m).
Pre-Install Preparation
You should complete the following steps before going on-site to perform an installation:
Configure Your Network in the Dashboard
The following is a brief overview of the steps required to add an MV63 series camera to your network. For detailed instructions about creating, configuring and
managing Meraki Camera networks, refer to the online documentation (https://documentation.meraki.com/MV).
1. Login to http://dashboard.meraki.com. If this is your first time, create a new account.
2. Find the network to which you plan to add your cameras or create a new network.
3. Add your cameras to your network. You will need your Meraki order number (found on your invoice) or the serial number of each camera, which looks
like Qxxx-xxxx-xxxx and is found on the bottom of the unit.
4. Verify that the camera is now listed under Cameras > Monitor > Cameras.
Check and Configure Firewall Settings
If a firewall is in place, it must allow outgoing connections on particular ports to IP addresses. The most current list of outbound ports and IP addresses for your
organization can be found under Help>Firewall Info on the dashboard.
DNS Configuration Best practices for LAN Streaming
Each camera will generate a unique domain name for secured direct streaming functionality. These domain names resolve an A record for the private IP address
of the camera. Any public recursive DNS server will resolve this domain.
If utilizing an on-site DNS server, please whitelist *.devices.meraki.direct or configure a conditional forwarder so that local domains are not appended to
*.devices.meraki.direct and that these domain requests are forwarded to Google public DNS.
•Type: Self-Tapping Screw
•Size: M4
•Length: Minimum 25mm
•Screw head diameter: Maximum 10mm
•Driver Type: ANY (eg: Philips)
•Head Type: ANY (Eg: Pan Head)
•Build Material: Stainless Steel
Note: The insertion diameter of the anchor should be smaller than that of the screw, and the length of the anchor should be longer than that of the
screw. The appropriate anchor should be selected based on the structure that it will be installed on, such as concrete, brick, wood, drywall, etc.
3