9
2
SEnS
Now it is shown on the bottom display (YES or no) whether the dryer is equipped with a residual moisture system with humidity
sensors.
Change this setting, if necessary, with the top button.
Press the middle button to continue.
If “no” was selected, then the display switches immediately to “bEEP”
SE.LE
Thebottom display indicates the calibration of thehumidity sensors (Sensor level). This is normally setat 5. If the drying results
are continuously too dry or too humid, then this value can be changed between 0 and 10. The lower this factor is set, the dryer
are the drying results. Is this value higher, then the drying results are more humid.
Ifthisfactorischanged,thenthiswillautomaticallyhaveaninfluenceonalldryingprogramswithresidualmoisturecontrol.
It is normally not necessary to change this factor. It is only meant to give the technicians the possibility to optimize the
drying results when the dryer is used in rather unusual environments.
Change this setting, if necessary, with the top button.
Press the middle button to continue.
St.Pr
Now the bottom display indicates (YES or no) whether the standard programs (31-40) should be shown.
Change this setting, if necessary, with the top button.
Press the middle button to continue.
Pr.CY
Here the bottom display indicates (YES or no) whether the cycle contact needs to be programmable. If yes, then the cycle contact
willduringthecyclecloseandopenagainalternately(pulsatingfunction).If"no"isselected,thenthecontactwillbeclosedduring
the entire drying cycle.
Change this setting, if necessary, with the top button.
Press the middle button to continue.
bEEP
The bottom display indicates (YES or no) whether a buzzer will sound at the end of the cycle.
Change this setting, if necessary, with the top button.
Press the middle button to continue.
tMP.1
The bottom display indicates the temperature inside the cylinder. This is meant as a test of the temperature sensor.
Press the middle button to continue.
If “no” was selected with “SEnS”, then the display will automatically go on to “End”
HuM.1
The bottom display now indicates the humidity inside the cylinder. This is meant as a test of the humidity sensor.
Press the middle button to continue.
tMP.2
The bottom display now indicates the temperature in the room. This is meant as a test of the temperature sensor.
Press the middle button to continue.
HuM.2
The bottom display now indicates the humidity in the room. This is meant as a test of the humidity sensor.
Press the middle button to continue.
End
This is the end of the technical menu
Press the middle button to continue.
Now the display shows IPSO for a while and then goes back to the beginning of the technical menu.