© 29SEP16 Clare Controls, LLC. 1 / 4 Doc ID - 904 • REV 06
CLIQ.express Controller Installation Sheet
Last modified: 09/29/16
Description
The CLIQ.express is Clare Controls’ entry-level controller for
home automation that integrates a broad range of common
interface elements into a single unit. It provides device
management services to AppModules, supports Clare user
interface services, and acts as the gateway to the ClareCloud
for system updates. The controller comes complete with the
ClareOS and all AppModules preloaded.
Note: Models, and their appearance, are subject to change
without prior notice.
WARNING: Any changes or modifications made to this product
not expressly authorized by the manufacturer could void the
user’s right to operate this device.
Unpacking the CLIQ.express
Remove all contents from the CLIQ.express packaging and
ensure you have the following items.
 1 × CLIQ.express device
 1 × power supply
 1 × RJ12 to DB-9 cable (null modem)
 1 × antenna and extender cable
 4 × rubber foot covers
Record the device’s UUID number (labeled on the bottom of
the device) on the line below, or scan the QR code (also on the
label) with a scanning app, and then email the number to your
system programmer. Your system programmer will need this
UUID information to configure the CLIQ.express device.
UUID: __________________________________
Do not use this UUID for more than one account.
WARNING: Do not apply power to the CLIQ.express until
installation is complete. Failure to do so may result in bodily
injury and/or damage to the equipment.
Installation
The CLIQ.express can be mounted in a structured enclosure,
set on a rack shelf, or placed in any room near your devices.
Note: The CLIQ.express contains a 908.4 MHz transceiver. To
prevent radio frequency (RF) interference from external
sources, we recommend that you place the CLIQ.express
away from devices that may cause interference and away from
conductive metals.
Mounting the CLIQ.express in a structured
enclosure
When mounting the CLIQ.express in a structured enclosure,
we recommend using the Leviton Structured Media Enclosure
or the Suttle SOHO Access Enclosure panels fitted with the
ClareHome Structured Enclosure Extender (P/N CH-EXT-28
and CH-EXT-42) for added protection against heat build-up.
(Panels and extenders are sold separately.)
To mount the CLIQ.express in a structured enclosure:
1. Place the CLIQ.express inside the structured enclosure
with the rear of the device facing up. See Figure 1.
2. Using cable ties, secure the CLIQ.express to the
enclosure.
Note: Be sure to leave at least 1U of spacing (1.75 in.
(4.45 cm)) above and below the CLIQ.express when mounting.
Figure 1: CLIQ.express mounted in a structured enclosure
(1) Mount CLIQ.express with cable ties
(1)
2 / 4 Doc ID - 904 • REV 06
Connecting devices to the CLIQ.express
After placing your CLIQ.express, make the connections to your
other devices. Figures 2 and 3 identify the LEDs and ports on
the front and rear of the CLIQ.express. Refer to the
documentation that came with each of your other devices for
detailed information about connecting those devices to the
CLIQ.express.
To connect the CLIQ.express:
1. Connect your serial devices (optional) to the RS-232 port
using an RJ12 to RS-232 adapter cable, or an RJ12 to
DB-9 null modem cable (included). See Figure 3, item 1.
For RJ12 pinouts, see Figure 6.
Note: The Console port is a service port used by Clare
Controls and not used with normal applications.
2. Connect a device, such as the optional CS-BR-1 Streams
Audio Bridge to a USB port on the CLIQ.express, See
Figure 3, item 3.
3. Use an Ethernet cable (not included) to connect your
CobraNet switch to the port labeled “CobraNet.” See
Figure 3, item 4.
Note: The CobraNet port is preset with the static IP
address 172.30.100.1. All CobraNet devices used on the
same subnet must use an address from 172.30.100.2 to
172.30.100.254.
4. Use an Ethernet cable (not included) to connect to your
data network switch to the port labeled “Ethernet.” See
Figure 3, item 5.
Notes
 The Network port is preset to DHCP. If you are using
the Streaming Media server in your project, a fixed IP
address is not required and should be configured as
“localhost.”
 If you are using a device, such as an RTI remote that
requires the controller to have a fixed IP, you must set
the fixed IP using a MAC/DHCP reservation on the local
router.
5. Attach the 908.4 MHz antenna or optional antenna
extender to the antenna port. See “Attaching the antenna”
below.
Figure 2: CLIQ.express front
(1) LED – It illuminates purple when booting and blue when running
normally.
Figure 3: CLIQ.express rear connections
(1) RS232 (1 port)
(2) Console (factory use, only)
(3) USB ports
(4) CobraNet
(5) Ethernet
(6) Antenna
(7) Power – 12 VDC
Attaching the antenna
The 908.4 MHz antenna can be mounted to the CLIQ.express
controller, or further away using an extender cable (included)
to enhance radio performance. When mounting the
CLIQ.express inside a structured enclosure, always mount the
antenna outside the enclosure using the extender cable.
To attach the antenna directly to the CLIQ.express:
1. Remove the antenna from its packaging.
2. Screw antenna to the antenna port on the rear of the
CLIQ.express until the antenna is snug. Do not over-
tighten the antenna. See Figure 4.
Figure 4: Attaching the antenna to the CLIQ.express
To attach the antenna using the extender cable:
1. Using a 17/64 in. drill bit, drill a hole in the sidewall of the
ClareHome Structured Enclosure Extender, near the
CLIQ.express.
2. On the extender cable, remove the locknut and washer
from the SMA Male connector. See Figure 5.
RS232 USB CobraNet Ethernet 12vdc
Networks
#1 #2
(1) (3) (4) (5) (6) (7)
Console
(2)
Doc ID - 904 • REV 06 3 / 4
3. Insert the threaded end though the hole, and then replace
the washer and locknut, tightening the locknut until the
connector is secure and does not wobble in the hole.
4. Screw the antenna to the connector until the antenna is
snug.
5. Attach the other end of the extender cable to the antenna
port on the rear of the CLIQ.express. See Figure 3, item 6.
Figure 5: Attaching the antenna with the extender cable
(1) SMA Male connector
(2) Washer
(3) Locknut
RS-232 port pinouts
If you are using your own RJ12 cable (rather than the one
supplied), ensure your RJ12 cable connector pinouts match
the pinouts on the RS232 port, as shown in Figure 6.
Figure 6: RS-232 port #1 with pinouts
Powering the CLIQ.express
Plugging in the power adapter automatically turns on the
CLIQ.express and starts the boot process.
To connect power to the CLIQ.express:
1. Plug the power adapter into a power receptacle on the
back of the CLIQ.express labeled “12vdc.” See
Figure 3, item 7.
2. Check the LED on the front of the CLIQ.express. It
illuminates when the device is receiving power. See
Figure 2, item 1.
Time, date, and time zone
Your CLIQ.express controller automatically detects and sets its
time, date, and time zone when you connect it to your data
network. CLIQ.express uses NTP and synchronizes the date
and time at boot up and periodically throughout the day.
Configure, test, and deploy a project
Refer to the Clare Controls Knowledge Base Fusion Help for
instructions on creating, testing, and deploying a project. When
you deploy the project from Fusion, it will deploy to the
CLIQ.express.
Attaching a CLIQ.connect
When attaching a CLIQ.express to a CLIQ.connect, you must
attach the CLIQ.express over the CLIQ.connect.
Adding the rubber foot covers
To prevent the unit from sliding, use the four rubber foot covers
included with your CLIQ.express.
 Peel each foot cover from the paper backing and place
one on each foot on the bottom of the CLIQ.express.
Specifications
I/O ports
USB 2.0
2
Ethernet LAN
1
RS232 [1]
1
CobraNet
1
General
Processor
Freescale iMX6
Operating system
Linux
Memory
2 GB DRAM, 1 GB NAND Flash
Power
8.4 W (700 mA at 12 VDC)
Operating temperature
41 to 113°F (5 to 45°C)
Relative humidity
10 to 90%, non-condensing
Dimensions (W × H × D)
1.3 × 8 × 6 in.
3.3 × 20.32 × 15.24 cm
[1] CLIQ.express supports RS232 speeds of 300 baud and higher.
(1) (3)
(2)
RS232
#1
4 / 4 Doc ID - 904 • REV 06
Regulatory information
Manufacturer
Clare Controls, LLC.
7519 Pennsylvania Ave, Suite 104
Sarasota, FL 34243
FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Warranty information
Clare Controls offers a three (3) year limited warranty on
original Clare Controls components, from the date of shipment
from Clare Controls. To view complete limited warranty details,
including limitations and exclusions,
www.clarecontrols.com/warranty.
Scan the code
to view product
warranty details.
Contact information
Clare Controls
7519 Pennsylvania Ave, Suite 104
Sarasota, FL 34243
Support: 941.404.1072
Fax: 941.870.9646
www.clarecontrols.com

Other Clare Controls Controllers manuals

Clare Controls CLIQ.host Assembly instructions

Clare Controls

Clare Controls CLIQ.host Assembly instructions

Clare Controls CLIQ.lite Controller Assembly instructions

Clare Controls

Clare Controls CLIQ.lite Controller Assembly instructions

Clare Controls CLIQ.host Assembly instructions

Clare Controls

Clare Controls CLIQ.host Assembly instructions

Clare Controls CH-OS-L Assembly instructions

Clare Controls

Clare Controls CH-OS-L Assembly instructions

Clare Controls CLIQ.mini Assembly instructions

Clare Controls

Clare Controls CLIQ.mini Assembly instructions

Clare Controls CLIQ.mini User manual

Clare Controls

Clare Controls CLIQ.mini User manual

Popular Controllers manuals by other brands

CARLO GAVAZZI Sx2WEB Series manual

CARLO GAVAZZI

CARLO GAVAZZI Sx2WEB Series manual

Xylem Bell & Gossett Zone Trol II Z-1 instruction manual

Xylem

Xylem Bell & Gossett Zone Trol II Z-1 instruction manual

Chauvet CH-751 user guide

Chauvet

Chauvet CH-751 user guide

Siemens SIPART DR22 Assembly and Installation Information

Siemens

Siemens SIPART DR22 Assembly and Installation Information

Inter-m ECS-6216P Operation manual

Inter-m

Inter-m ECS-6216P Operation manual

Lanner HLM-1001 user manual

Lanner

Lanner HLM-1001 user manual

Tyco DigiTrace 920 Series Installation, operating and maintenance manual

Tyco

Tyco DigiTrace 920 Series Installation, operating and maintenance manual

LSIS XGT Series user manual

LSIS

LSIS XGT Series user manual

Meilhaus Electronic USB-GT Series manual

Meilhaus Electronic

Meilhaus Electronic USB-GT Series manual

GREER Company MicroGuard MG510 Installation, Calibration and Troubleshooting Manual

GREER Company

GREER Company MicroGuard MG510 Installation, Calibration and Troubleshooting Manual

Servonaut S22 manual

Servonaut

Servonaut S22 manual

EUROSTER 10M Installation and operation manual

EUROSTER

EUROSTER 10M Installation and operation manual

halstrup-walcher PSD4 Series instruction manual

halstrup-walcher

halstrup-walcher PSD4 Series instruction manual

Viking MLC-24 Technical practice

Viking

Viking MLC-24 Technical practice

nVent RAYCHEM Elexant 450c Operation manual

nVent RAYCHEM

nVent RAYCHEM Elexant 450c Operation manual

AAON ASM02655 Technical guide

AAON

AAON ASM02655 Technical guide

NOVAK ATOM AND CYCLONE ESC manual

NOVAK

NOVAK ATOM AND CYCLONE ESC manual

Trane 700 user guide

Trane

Trane 700 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.