Clare Controls CLIQ.lite Controller Assembly instructions

© 22OCT15 Clare Controls, Inc. 1 / 4 Doc ID - 724 • REV 07
CLIQ.lite Controller Installation Sheet
Last modified: 10/22/15
Description
The Clare Controls CLIQ.lite in-home controller is the entry
point for Clare Controls’ home automation solutions. The
CLIQ.lite runs on the same hardware platform as the full-
featured CLIQ.host. The CLIQ.lite is a scaled version of the
CLIQ.host, yet it supports all of the same applications. As your
customer’s needs grow, you can upgrade the CLIQ.lite with all
the functions of a CLIQ.host, via a simple license update. If
further expansion is necessary, you can add a CLIQ.connect
module to nearly double the controller’s I/O ports.
WARNING: Any changes or modifications made to this product
not expressly authorized by the manufacturer could void the
user’s right to operate this device.
Unpacking the CLIQ.lite
Remove all contents from the CLIQ.lite packaging and ensure
you have the following items.
1 × CLIQ.lite device
1 × power supply
3 × terminal connectors
1 × terminal connector jig
2 × RJ12 to DB-9 cables (null modem)
6 × IR emitters
1 × Z-Wave antenna and extender cable
4 × rubber foot covers
Record the device’s UUID number (labeled on the bottom of
the device) on the line below, or scan the QR code (also on the
label) with a scanning app, and then email the number to your
system programmer. Your system programmer will need this
information to configure the CLIQ.lite device.
UUID: __________________________________
Do not use this UUID for more than one account.
WARNING: Do not apply power to the CLIQ.lite until
installation is complete. Failure to do so may result in bodily
injury and/or damage to the equipment.
Installation
The CLIQ.lite can be mounted in a structured enclosure, set on
a rack shelf, or placed in any room near your devices.
Note: The CLIQ.lite contains a Z-Wave radio. To prevent radio
frequency (RF) interference from external sources, we
recommend that you place the CLIQ.lite away from devices
that may cause interference and away from conductive metals.
Mounting the CLIQ.lite in a structured enclosure
When mounting the CLIQ.lite in a structured enclosure, we
recommend using the Leviton Structured Media Enclosure or
the Suttle SOHO Access Enclosure panels fitted with the
ClareHome Structured Enclosure Extender (P/N CH-EXT-28
and CH-EXT-42) for added protection against heat build-up.
(Panels and extenders are sold separately.)
To mount the CLIQ.lite in a structured enclosure:
1. Place the CLIQ.lite inside the structured enclosure with the
rear of the device facing up, see Figure 1.
2. Using cable ties, secure the CLIQ.lite to the enclosure.
Note: Be sure to leave at least 1U of spacing (1.75 in.
(4.45 cm)) above and below the CLIQ.lite when mounting.

2 / 4 Doc ID - 724 • REV 07
Figure 1: CLIQ.lite mounted in a structured enclosure
(1) Mount CLIQ.lite with cable ties
Connecting devices to the CLIQ.lite
After placing your CLIQ.lite, make the connections to your
other devices. Figures 2 and 3 identify the LEDs and ports on
the front and rear of the CLIQ.lite. Refer to the documentation
that came with each of your other devices for detailed
information about connecting those devices to the CLIQ.lite.
To connect the CLIQ.lite:
1. Connect your serial devices (optional) to either of the two
RS-232 ports using an RJ12 to RS-232 cable, or an RJ12
to DB9 null modem cable (included). See Figure 3, item 1.
For RJ12 pinouts, see Figure 6.
2. Connect your IR devices (optional) to the 12-pin terminal
connector (included), and then insert the connector into
the port labeled “IR Outputs.” See Figure 3, item 2.
If your IR device comes with a 3.5 mm connector, you will
need to cut and strip the wires before connecting it to the
terminal connector.
Note: When connecting an IR emitter (included), attach
the striped wire to positive (+) and the black wire to
negative (-).
3. Connect a CS-BR-1 Streams Audio Bridge (optional) to a
USB port on the CLIQ.lite. See Figure 3, item 3.
Note: The USB connection allows the CS-BR-1 to encode
up to three simultaneous audio streams onto the CobraNet
network.
4. Connect your digital I/O devices (optional) to the 8-pin
terminal connector, and then insert the terminal connector
into the port labeled “I/O.” See Figure 3, item 4.
When connecting devices, wire it such that ports 1 and 2
share the same 12 VDC power and ground and ports 3
and 4 share the same power and ground.
5. Use and Ethernet cable (not included) to connect your
CobraNet switch to the port labeled “CobraNet.” See
Figure 3, item 5.
Note: The CobraNet port is preset with the static IP
address 172.30.100.1. All CobraNet devices used on the
same subnet must use an address from 172.30.100.2 to
172.30.100.254.
6. Use an Ethernet cable (not included) to connect to your
data network switch to the port labeled “Ethernet.” See
Figure 3, item 6.
Notes
The Network port is preset to DHCP. If you are using
the Streaming Media server in your project, a fixed IP
address is not required and should be configured as
“localhost.”
If you are using a device, such as an RTI remote that
requires the controller to have a fixed IP, you must set
the fixed IP using a MAC/DHCP reservation on the local
router.
7. Connect relay contacts (e.g., garage door contacts) to the
6-pin terminal connector, and then insert the terminal
connector into the port labeled “Relay.” See Figure 3,
item 7.
8. Attach the Z-Wave antenna or optional Z-Wave antenna
extender to the Z-Wave port. See “Attaching the Z-Wave
antenna” below.
Figure 2: CLIQ.lite front
(1) LED – It illuminates purple when booting and blue when running
normally
Figure 3: CLIQ.lite rear connections
(1) RS-232 (2 ports)
(2) IR Outputs
(3) USB port
(4) I/O
(5) CobraNet
(6) Ethernet
(7) Relay
(8) Z-Wave antenna
(9) Power – 12 VDC
Attaching the Z-Wave antenna
The Z-Wave antenna can be mounted to the CLIQ.lite
controller, or further away using an extender cable (included)
to enhance radio performance. When mounting the CLIQ.lite
inside a structured enclosure, always mount the antenna
outside the enclosure using the extender cable.
To attach the antenna directly to the CLIQ.lite:
1. Remove the Z-Wave antenna from its packaging.
2. Screw antenna to the antenna port on the rear of the
CLIQ.lite until the antenna is snug. Do not over-tighten the
antenna. See Figure 4.
(1)
RS232 IR Outputs USB I/O CobraNet Ethernet Relay
#1 #2
12vdc
Networks
#1 #2 1 2 3456
12vdc
Gnd
#3
#1
#2
12vdc
Gnd
#4
NC
NO
C
NC
NO
C
(1) (2) (3) (4) (5) (6) (7) (8) (9)

Doc ID - 724 • REV 07 3 / 4
Figure 4: Attaching the antenna to the CLIQ.lite
To attach the antenna using the extender cable:
1. Using a 17/64 in. drill bit, drill a hole in the sidewall of the
ClareHome Structured Enclosure Extender, near the
CLIQ.lite.
2. On the extender cable, remove the locknut and washer
from the SMA Male connector. See Figure 5.
3. Insert the threaded end though the hole, and then replace
the washer and locknut, tightening the locknut until the
connector is secure and does not wobble in the hole.
4. Screw the Z-Wave antenna to the connector until the
antenna is snug.
5. Attach the other end of the extender cable to the antenna
port on the rear of the CLIQ.lite. See Figure 3, item 8.
Figure 5: Attaching the antenna with the extender cable
(1) SMA Male connector
(2) Washer
(3) Locknut
RS-232 port pinouts
If you are using your own RJ12 cable (rather than the one
supplied), ensure your RJ12 cable connector pinouts match
the pinouts on the RS-232 ports shown in Figure 6.
Figure 6: RS-232 ports with pinouts
(1) (3)
(2)
RS232
#1 #2

4 / 4 Doc ID - 724 • REV 07
Powering the CLIQ.lite
Plugging in the power adapter automatically turns on the
CLIQ.lite and starts the boot process.
To connect power to the CLIQ.lite:
1. Plug one end of the power adapter into a power receptacle
on the back of the CLIQ.lite labeled “12vdc.” See
Figure 3, item 9.
2. Check the LED on the front of the CLIQ.lite. It illuminates
purple when booting and blue when running normally. See
Figure 2, item 1.
Time, date, and time zone
Your CLIQ.lite controller automatically detects and sets its
time, date, and time zone when you connect it to your data
network. CLIQ.lite uses NTP and synchronizes the date and
time at boot up and periodically throughout the day.
Configure, test, and deploy a project
Refer to the Clare Controls Knowledge Base Fusion Help for
instructions on creating, testing, and deploying a project. When
you deploy the project from Fusion, it will deploy to the
CLIQ.lite.
Adding the rubber foot covers
To prevent the unit from sliding, use the four rubber foot covers
included with your CLIQ.lite.
To add the rubber feet:
Peel each foot cover from the paper backing and place
one on each foot on the bottom of the CLIQ.lite.
Upgrading your CLIQ.lite license
With a simple license update, you can upgrade your CLIQ.lite
to have the same unlimited functions as a CLIQ.host. To
upgrade your license, contact our Technical Support group at
the numbers listed in the “Contact information” section. Before
calling, be sure you have the following information available.
License key number
UUID (listed on the bottom of the unit)
Dealer name and address
Regulatory information
Manufacturer
Clare Controls, Inc.
7519 Pennsylvania Ave, Suite 104
Sarasota, FL 34243
FCC compliance
This device complies with part 15 of the FCC
Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any
interference received, including interference that
may cause undesired operation.
Specifications
Applications supported
Audio zones
4 zones
Audio streams
3
Lighting
10 circuits
Security
1 partition, 8 zones
Thermostats
2
Cameras
2
Pool spa
Not supported
Entertainment
4
I/O ports
RS-232 [1]
2
IR outputs
6 (2 pins per IR)
USB [2]
2
I/O
4 (8 pins)
CobraNet
1
Ethernet
1
Relay
6 pin, (2 normally open, 2 normally closed)
General
Processor
Freescale iMX6
Operating system
Linux
Memory
2 GB DRAM, 1 GB NAND Flash
Power
8.4 W (700 mA at 12 VDC)
Operating temperature
41 to 113°F (5 to 45°C)
Relative humidity
10 to 90%, non-condensing
Dimensions (W × H × D)
1.3 × 8 × 6 in. (3.3 × 20.32 × 15.24 cm)
[1] CLIQ.lite units support RS232 speeds of 300 baud and higher.
[2] CLIQ.lite units marked Rev C or higher use both USB ports. Units
marked Rev B or lower, or with a numerical revision level, are use the
top USB port only. See the label on the bottom of the unit to
determine its revision level.
Contact information
Clare Controls, Inc.
7519 Pennsylvania Ave, Suite 104
Sarasota, FL 34243
Support: 941.404.1072
Fax: 941.870.9646
http://support.clarecontrols.com
www.clarecontrols.com
Other Clare Controls Controllers manuals

Clare Controls
Clare Controls CLIQ.mini User manual

Clare Controls
Clare Controls CLIQ.host Assembly instructions

Clare Controls
Clare Controls CH-OS-L Assembly instructions

Clare Controls
Clare Controls CLIQ.express Assembly instructions

Clare Controls
Clare Controls CLIQ.host Assembly instructions

Clare Controls
Clare Controls CLIQ.mini Assembly instructions
Popular Controllers manuals by other brands

Tyco
Tyco DigiTrace 920 Series Installation, operating and maintenance manual

LSIS
LSIS XGT Series user manual

Meilhaus Electronic
Meilhaus Electronic USB-GT Series manual

GREER Company
GREER Company MicroGuard MG510 Installation, Calibration and Troubleshooting Manual

Servonaut
Servonaut S22 manual

EUROSTER