Thank you for purchasing the inno ati e Clean Air Optima CA-602 ultrasonic humidifier with
Ionizer.
We wish you many years of healthy indoor air with this efficient and effecti e product.
Ensure that all safety precautions are followed when using this electrical appliance for the proper
operation of the de ice. These instructions describe the safety precautions to be obser ed during
operation. They are designed to pre ent injuries or damage to this de ice.
Safety Precautions
The inner ultrasonic transducer is highly sensiti e. Do not touch it with bare fingers or
scrape it with metal tools, or it will reduce mist output. When cleaning this area please use
a small cleaning brush, cotton swab or tooth brush. Do not use hot water as it may damage
the misting parts.
Use proper oltage - AC 110~120V 60Hz in Canada/USA; AC 220~240V 50Hz in Europe.
Use of improper oltage may cause fire hazard or electric shock.
To pre ent electric shock, do not dismantle, repair or modify this product. Maintenance and
cleaning should be followed exactly as instructed in this manual. In the e ent of a
malfunction, please contact an authorized Clean Air Optima maintenance center.
Do not use in areas where flammable or explosi e materials are stored.
Do not place this de ice in direct sunlight or near objects that generate high temperature
heat. The heat may cause deformation or warping of the outer casing.
Do not use the humidifier in a room that already has humidity le els abo e 50% relati e
humidity. Excessi e humidity in the room gi es rise to condensation on cold surfaces such
as walls or windows.
Do not operate the unit without water in the basin.
Do not insert foreign objects into the de ice. Do not touch the transducer or the lower
water basin when the unit is operating. Do not scratch the transducer. Do not touch the
mist output when producing warm mist.
Do not submerge this de ice in water. Water or cleaning liquids may only be used on parts
to be cleaned according to the cleaning and maintenance instructions.
Only use lime scale remo er or inegar to clean mineral deposits from the basin or
transducer. Do not use any harsh detergents that may damage the unit.
If you smell an abnormal odour, please turn off and unplug the unit and call Clean Air
Optima technical support.
Clean and dry the de ice before storage (including the remo al of all water from the inside
of the de ice). Store the machine in a cool and dry place outside the reach of children.
Do not use fabrics or other materials to co er this de ice. Obstructed air inlets and outlets
will result in improper operation of this unit and may result in fire or other damage.
To pre ent interference and damage to other electronic de ices, this machine should be
placed at least 1 meter away from a computer, tele ision, radio or other electronic
equipment.
The ultrasonic humidifier should be cleaned regularly for proper operation and long life. See
cleaning instructions.
The high frequency ibrations cannot be heard by humans or animals, and are completely
safe.
For safety reasons and to pre ent fire or electric shock, unplug the power cord from the
electric outlet socket whene er you:
-Do not use the de ice for a long period of time.
-Remo e the tank, clean or ser ice the machine or the permanent filter.
-Mo e or transport the de ice.
If the power cord is damaged, then it must be replaced by an authorized ser ice person to pre ent
electric shock or fire.

3
Diagram humidifier CA-602

4
Aromatherapy
Important
In order to reach the best results and to enjoy your CLEAN AIR OP IMA ultrasonic air
humidifier as much as possible, we ad ise to read carefully the following instructions regarding
the use of essential oils in the ultrasonic air humidifier CA-602 by CLEAN AIR OP IMA.
Use of essential oils in the CLEAN AIR OP IMA CA-602
Use our high quality essential oils and enjoy your personal aromatherapy! A scent sensation at its
highest le el!
You can find high quality essential oils in our assortment. They perfectly fit to the CLEAN AIR
OP IMA ultrasonic air humidifier CA-602 and have been specially developed for the use
with this ultrasonic humidifier.
Effectiveness
Essential oils (also called olatile oils) stimulate our olfactory sense through their olatility and are
percei ed as aromatic. Essential oils naturally e aporate with time.
The air humidifier CA-602 by Clean Air Optima works according to the newest nebulisation
technology based on ultrasound in order to atomise essential oils and water into microscopically
small drops. Thanks to this technology the components and the water can unfold their beneficial
potential for humans.
Filling and refilling with essential oils:
o order:
www.cleanairoptima.co.uk
www.cleanairoptima.com
Open the aroma box at the backside of the de ice, pour 5 – 10 drops of your fa orite essential oil on the pad and
close the aroma box. In order to reach the best effect, please ONLY use the high quality essential oils and
compositions from the Clean Air Optima assortment.
Warni
ng!
The use of other essential oils not made for this air humidifier or other additives (for example pure
essential oils, fragrances, water purification products) can damage the air humidifier and must NOT
be used! Even a small quantity can damage the plastic and cause cracks. The material is not made
for the use of additives. One drop is enough to damage the water tank/ basin and disable the
device. Devices that are damaged through additives are excluded from the guarantee.

5
The Clean Air Optima CA-602 is equipped with a Permanent Reusable White Dust & Anti-
Microbial Filter. It consists of an inner cylinder, an outer co er and a number of small plastic and
ceramic balls. The plastic balls are embedded with nano-sil er, an anti-microbial agent designed to
purify the water and destroy microbes such as bacteria and mould. The ceramic balls function to
soften the water by adhering to minerals that cause white dust. They also ser e to remo e any
unpleasant odour from the water. The filter requires cleaning about once a month or 1,000 hours of
use. See the Maintenance section of more information.
Operating Instructions
Before getting started, please remo e the Clean Air Optima CA-602 from its box and allow it to
become accustomed to the room temperature for at least 30 minutes especially if the machine is
cold from the outside air. The CA-602 is designed to operate at temperatures between 5 -40 ºC
and relati e humidity of less than 80%.
To get started, first remo e the nozzele than flip the tank o er and unscrew and remo e the water
tank lid and filter.
Then place the water tank under the faucet for filling. Fill the tank with tap water (or other clean
water source with water temperature under 40ºC), re-insert the lid and filter. Flip the water tank
once again until it is on the right side up. Ensure that the basin is clean and then carefully place
the water tank back on the lower body.
Wait a few seconds until the water tank lid starts to release water into the basin. You will hear a
bubbling sound as the air enters the water tank. Plug the power cord into the electrical outlet
(NEVER SWITCH ON THE HUMIDIFIER WITHOUT WATER IN THE BASIN).
Turn the “Power knob ON/OFF” to the right to turn the humidifier on. The water will be turned
into micro-fine steam trough high frequency ibration, which will be dispensed into the indoor air
and directly e aporates. Make sure that the steam does not face electrical sockets, walls or other
objects.
Turn the “Max – Mid - Min knob” to the right to adjust the amount of mist output.
Push the “ION” button to turn the Ionizer and LED light on.
The air will be enriched with additional negati e ions. The integrated ionizer cleans and refreshes
the air with additional negati e oxygen ions. The effect is completely natural: After a summer
thunderstorm the air is filled with negati e ions and especially fresh.
Amount of ions per cubic centimetre air:
In high altitude: 8000 ions /ccm
At sea le el: 4000 ions / ccm
Countryside: 1200 ions / ccm
In the city: 2000 ions / ccm
In the office: Only 20 ions / ccm
In case there is no or too little water in the tank you will hear a signal.

6
Humidity
The percentage of water steam in a room and the temperature are the relati e air humidity. The air
contains more or less air humidity. The ration of water steam to the air aries with the different
temperature. The higher the temperature in the room, the less water steam will be in the air. In
winter the cold air from outside enters the room, the relati e air humidity decreases. The air
humidity can be increased with the Clean Air Optima air humidifiers.
The relati e air humidity should be:
Bed and li ing room: 45 -60 %
Examination room: 40 – 50 %
Library: 40 – 50 %
Troubleshooting
The following is a troubling shooting guide to help you sol e any issues that you may ha e with the
operation of the Clean Air Optima CA-602.
TROUBLESHOOTING
Possible reasons
Trouble Possible reasons Solution
Power icon is off or does not Humidifier not plugged into the Connect power cord to electrical
work. power outlet. outlet and turn rotary knob.
Power light is on but no mist. No water in water tank. Fill water tank with water.
The mist has a strange odour. A new machine. Remo e the water tank, unscrew
the lid and let it air out in a cool
area for 12 hours.
It either has dirty water or the water Clean the water tank and refill
has been stagnant too long. with clean water.
Power light is on, but the Too much water in the water basin. Remo e the water tank. Take a
machine doesn’t work. small cup and remo e some of
the water from the machine’s
water basin. Reinsert the water
tank and make sure that it sits
properly.
The olume of spray mist is too Too much mineral scale in the water Clean transducer.
low. basin.
Water is too dirty or water was kept too Clean the water tank and refill
long in the tank. with clean water.
Abnormal noise Vibration in the water tank because Fill the water tank.
the water le el is too low.
Machine is on an unstable surface. Mo e the unit to a stable flat
surface.
Spray mist is coming out of the There are gaps between the housing Remo e the jet nozzle from the
area around the jet. around jet nozzle and the top of the top of the water tank and clean
water tank. with a damp cloth. Reattach to
the water tank.

7
he following is not considered faulty operation:
If your water is ery hard (containing abnormally high le els of minerals) the humidifier
may produce white dust. This is not a malfunction. The solution would be to clean the
filter more often or use softer water.
If you stand ery close to the humidifier, you will hear the gurgling sound of water. This
is normal.
The machine operates ery quietly but it is not completely silent. Noise le els less than
25 db is considered normal.
WARNING!
If the above recommended solutions do not work, please contact Clean Air Optima technical
support at the telephone number for your region. Do not attempt to disassemble, repair
and reassemble the machine as it may void the warranty.
TROUBLESHOOTING
Cleaning and Maintenance
You can ensure many years of trouble free operation of your Clean Air Optima CA-602 humidifier
by following a few simple maintenance procedures. If your water is hard, containing high
concentrations of calcium and other minerals, then o er a period of time white dust will start to
deposit on the arious surfaces in the room. A white, film-like substance will also start to de elop
in the water basin, on the transducer and on the inner surface of the water tank. This white film
will impede the proper function of the transducer and the operation of the machine.
We recommend the following
1. If your water is ery hard, we recommend that you boil it first, allow it to cool completely
before use in the humidifier. The boiling will reduce the mineral concentration in the water.
The other option is to use distilled water if your mineral le el is still too high.
2. If you are using the machine on a daily basis, clean the transducer, water tank and basin
once a week.
3. When the water tank needs a refill, empty the remaining water from the tank and fill it with
fresh water.
4. Clean the whole machine and make sure to keep all the parts completely dry when the
machine is not in use.
How to clean the transducer
1. Place 5-10 drops of inegar on the surface of the transducer and wait for 2-5 minutes.
2. Using a small brush, cotton swab or tooth brush, gently clean the mineral film from the
surface of the transducer.
3. Rinse the transducer with clean water.
4. Ne er use sharp or solid objects for cleaning the transduce
How to clean the water basin
1. Clean the water basin with a soft damp cloth. If there is excess film on the surfaces, then
soak the cloth with inegar and repeat the process.
2. If there is a film in any of the depressions along the basin, drop a bit of inegar into
depression and clean it out with a brush.
3. Rinse the basin with clean water.

8
How to clean the White Dust & Anti-Microbial Filter
1. Remo e the filter from the water tank.
2. Put some white inegar into a glass. Soak the filter in the inegar for about 10 minutes.
3. Remo e the filter from the glass and shake it se eral times.
4. Clean and rinse the filter once again with fresh water.
If you don’t plan to use the humidifier for a long time, remo e the filter from the water tank and let
it dry thoroughly. Then wrap it in protecti e packaging and keep it next to the humidifier in a cool,
dry and dark storage space.
Why humidify the Air?
When the air is dry, especially in the winter months, it can become unpleasant and e en unhealthy,
leading to increased le els of static electricity, dry skin, cracked lips and e en noise bleeds.
Optimal humidity is between 45 to 55% relati e humidity. During the winter months though,
relati e humidity in the a erage home can drop to below 20%. Low humidity can lead to a ariety
of conditions that cause ill health. Dust particles, bacteria, iruses, dust mite feces that are
normally trapped by the moist nasal membrane lining in the nose can more easily get into the
lungs when the air is dryer and thus reduce the body’s natural defence mechanism. These in aders
o erload the immune system and irritate the mucous membranes resulting in more coughing and
susceptibility to disease. The Clean Air Optima CA-602 is an ideal ultrasonic humidifier for
homes, apartments, offices and anywhere where is low humidity. Ultrasonic water apour is highly
beneficial to indi iduals. Their biggest ad antage is high performance combined with low energy
consumption.
Do not use additi es
Water additi es (e.g. essential oils, fragrances, water conditioners etc.) must NOT be used! E en a small
amount can cause damage to the tank material. The material is not suitable for the use of such
additi es. One drop is enough to damage the tank and render the appliance unusable. Appliances that
are damaged by su
ch additi es will not be co ered by the manufacturer’s warranty.

9
The major benefits
• Air humidification and air purification, refreshes and impro es indoor air quality
• 3-in1: Humidification, Purification and Aromatherapy!
• Permanent ceramic / nano-sil er filter: no replacement filters needed!
• Built-in Ionizer purifies the air additionally and pro ides fresh air
• Vitually silent operation ensures a quiet and restful sleep
• The ultrasonic is hygienically flawless if cleaned regularly and the
ceramic/nano-sil er cartridge is cleaned as indicated
• Permanent, easy to clean ceramic nano-sil er filter for control
of white dust, mould and bacteria
• Safely and automatically shuts off when it runs out of water
• Large capacity water tank (3,5L) easy refills with normal tap water
• Runs up to 3 nights or 30 ours without refilling (low setting)
• Sa e money. No wicks or filters to replace!
• Low power consumption
Applicable for small and larger rooms up to 375 ft² / 35m² / 80m³
Benefits of proper humidification
• reduces discomfort, tiredness, sickness
• reduces susceptibility to colds
• reduces chapped lips, dry, red eyes and dry, itchy skin
• helps to feel and sleep better
• can help you reco er sooner from a cold
• reduces damage to wooden objects
• reduces the negati e effect of dry air on musical instruments
• reduces static electricity charge
• helps to keep your oice tuned
Benefits of ionisation
Ionised air strengthens our defence systems and our itality and ionisation purifies the air by
reducing the particles, micro-organisms, iruses & allergens!
Product specifications
• Type: Clean Air Optima CA-602
• Ultrasonic humidifier for cold mist capacity
• Mist E aporation Rate: Low 120 ml / hr (3.4 fl oz) High 300 ml / hr (10.1 fl oz)
• Negati e Ion Output: 3.000.000/cm³ (49.161.000/inch³)
• Acti e oxygen <0.05 ppm
• Water tank capacity 3,5L
• Very low noise le el <25 dB
• Dimensions (LxWxH) 29,5 x 16 x 33,5 cm
• Weight: 1,7kg (8.2lbs) dry
• Color: white with transparent water tank
• Energy consumption only 30 watts
• Power supply 220 - 240V, 50/60 Hz
At the end of the product life cycle, you should not throw this machine into the normal household garbage but
bring the product to a collection point for the recycling of electrical and electronic equipment.

10
WARRANTY CERTIFICATE FOR THE Clean Air Optima
CA-602 ULTRASONIC HUMIDIFIER with Ionizer and
Aromatherapy
Date of purchase: ………………………………………………………………………………………………..
Customers name: ………………………………………………………………………………………………..
Address: …………………………………………………………………………………………………………..
Telephone: ………………………………………………………………………………………………………..
Email: ……………………………………………………………………………………………………………...
Seller’s name: ……………………………………………………………………………………………………
Address: ………………………………………………………………………………………………………….
1. Please fill in completely this Warranty Certificate. Send it with the in oice and the unit, postage
pre-paid and using the original packing box, to your distributor. Make sure to include the
appropriate return postage for the package.
2. Please enclose a short description of the damage, fault or malfunction, and the circumstances
under which these problems arose.
The Clean Air Optima CA-602 is subjected to strict testing procedures before lea ing the factory.
If within two years from the date of purchase the product does not perform according to the
specifications, because of factory defects, the purchaser is entitled to free repairs or replacement of
parts upon presentation of this warranty (pro ided that the malfunction or damage to the de ice
and/or parts occurred under normal operating conditions). What is co ered: All parts defecti e in
material and workmanship. For how long: Two years from purchase date. What we will do: Repair
or replace any defecti e parts. Exclusions: Regular replacement parts such as filter cartridges.
Other Conditions
The pro isions of this warranty are in lieu of any other written warranty whether express or
implied, written or oral, including any warranty of merchantability or fitness for a particular
purpose. The manufacturer’s maximum liability shall not exceed the actual purchase price paid by
you for the product. In no e ent shall the manufacturer be liable for special, incidental,
consequential, or indirect damages. This warranty does not co er a defect that has resulted from
improper or unreasonable use or maintenance, faulty assembly, accident, natural catastrophes,
improper packing, or unauthorized tampering, alteration, or modification as determined solely by
us. This warranty is oid if the label bearing the serial number has been remo ed or defaced.
Clean Air Service Center
Da id Ricardostraat 9-9
7559 SH Hengelo (o )
The Netherlands
Tel: + 31 (0) 74 - 2670145
Fax: + 31 (0) 74 - 2671789
E-mail: info@cleanairoptima.com
Internet: www.cleanairoptima.com
Table of contents
Other cleanAIR Humidifier manuals
Popular Humidifier manuals by other brands

Holmes
Holmes HM5305 owner's guide

Levoit
Levoit OasisMist LUH-O451S-WUS user manual

Winix
Winix L500 user manual

Okoia
Okoia HML6 operating instructions

Johnson Controls Unitary Products
Johnson Controls Unitary Products 8000 Residential Steam Humidifier owner's manual

Vicks
Vicks Mini Cool Mist User instructions