SAFETY INSTRUCTIONS - READ CAREFULLY!
When installing and using this electrical equipment, there are basic
safety precautions that should always be followed:
• Appliance should be supplied through a residual current device (RCD/GFCI type) with a rated
tripping current not exceeding 30mA.
• Electric installations should fulfil the requirements of local standards. Earthed appliances must
be permanently connected to fixed wiring.
• Any damage to electrical cable should be replaced by a competent party immediately before
further use.
• It’s recommended not to use an extension cord to connect the CleverSpa®to electrical supply.
• RISK OF ELECTRIC SHOCK. Never operate any external/additional electrical appliance when in
the CleverSpa® or when your body is wet. Keep electrical appliances away from the CleverSpa®.
• RISK OF ACCIDENTAL DROWNING. Children are forbidden from using the CleverSpa®unless they
are supervised at all times by a responsible adult.
• For health and safety reasons, we do not recommend children under 8 years old use our hot tubs.
For children 8 years + we recommend the temperature be set no higher than 37°C.
• When not in use, cover should be fitted and locked to help retain heat. This also prevents
unsupervised children accessing the CleverSpa®.
• Shower before using your CleverSpa®. Cosmetic products, lotions etc on skin can degrade
water quality.
• Do not switch on if there is any possibility that water in the CleverSpa®or control system is frozen.
• Pets should be kept away from your CleverSpa®at all times.
• Soaking in hot water during pregnancy can cause damage to the unborn foetus. If you have any
specific concerns please consult your doctor before continuing to use your hot tub.
• Use of alcohol, drugs or medication before or during use of your CleverSpa®can increase risk
of drowning.
Safety Instructions 02 - 03
CleverSpa®Parts Checklist 04
Before you setup your CleverSpa®05
Setting up your CleverSpa®06 - 07
How to setup your CleverSpa®Ambient LED Lighting 08 - 09
Operating your CleverSpa®10
Maintenance & Repair of your CleverSpa®11
Cleaning & Storing away your CleverSpa®12
Troubleshooting 13
Returns 14
Warranty 15
02
CONTENTS

• Those with history of heart disease, low/high blood pressure, circulatory system problems
or diabetes should consult a doctor before using CleverSpa®. People using medication should
consult their doctor before using the CleverSpa®. Some medications may cause drowsiness, whilst
other medication may aect heart rate, blood pressure and circulation during use.
• Water in a CleverSpa®should never exceed 42°C (107°F). Operating temperatures between
38-40OC (100-104°F) are considered safe for a healthy adult. Lower temperatures are
recommended for younger children, and when use exceeds 10 continuous minutes.
• A max temperature of 42OC can be programmed for the water - Once cover is removed, water
temperature will automatically drop as heat is released through evaporation. The additional
2OC compensates for heat loss that may occur. Once you are ready to use, reduce maximum
temperature to recommended 38-40OC(100-104°F) and ensure that temperature reading is no
greater than 40OC.
• Immediately get out of your CleverSpa®if you feel uncomfortable or sleepy.
• Do not turn CleverSpa®on when it is empty. This could cause irreparable damage to pump system
which would nullify any warranty period.
• To avoid damaging your pump & heating system during colder weather, your CleverSpa®is fitted
with 365 FreezeGuard Technology. Set the temperature to 5OC, and this will prevent any water in
the system from freezing.
• Always add chemicals to jug of water to avoid strong fumes or violent reactions that may result
in a hazardous chemical spray.
• To avoid accidental resetting of thermal cut-out, this appliance must not be supplied through an
external switching device, such as a timer, or connected to a circuit that is regularly switched on
and o by the utility.
• WARNING: Adequate drainage has to be provided to deal with overflow of water.
• IMPORTANT: For set-up/installation, the surface must be smooth, flat, level and capable of evenly
supporting the weight of the CleverSpa®, water and users e.g. 6 Person Square CleverSpa®filled
weight: 980kg (approx) plus combined weight of occupants.
It is the responsibility of the CleverSpa®owner to assure integrity of the site at all times.
03
SAFETY INSTRUCTIONS
WARNING - PLEASE READ CAREFULLY!
Do not operate pump and heating system whilst the CleverSpa®is empty.
This can damage the system and void your warranty.

04
Please check all parts are present in your box before first use.
To order new or missing parts please visit clevercompany.com
CLEVERSPA® PARTS CHECKLIST
FILTER CARTRIDGE (B)GROUNDSHEET (A)
SAFETY LOCKING
CLIP KEYS (H)
FILTER PROTECTOR
COVER (C)
CLIP-ON TOP COVER (E)INFLATION HOSE (D) REPAIR PATCHES (F)
DRAINAGE PLUG (G) LED LIGHTING KIT
(Where applicable)
Refer to pages 08 - 09
10.4A: Heat 7.8A & Bubble 2.6A
PRODUCT SPECIFICATION 208CM CIRCULAR
Capacity 4-6 People
Water Capacity (approx.) 1000L
Actual Water Flow (approx.) 1,325L/H
Inflated Size (approx.) 208 x 65cm
Product Weight (approx.) 26kgs
Filled Weight (approx.) 1,035kgs
No. Air Jets 130
Pump Voltage 220-240V–50Hz
Maximum Temperature 42oC (107oF)
Temperature Rise (approx.) 1.5-2oC/hr
Rated Power Input for Heating 1800W
Rated Power Input for Bubbling 600W
Rated Current for Heating Bubbling & Filtering

05
BEFORE YOU SET UP YOUR CLEVERSPA®
If your WiFi signal is poor all over your garden, please
contact your internet provider for further assistance.
Before setting up your CleverSpa®
with CleverLink®- find a strong WiFi signal
Before setting up your
CleverSpa®with LED Lights
DISTANCE FROM HOUSE
42
WIFI STRENGTH
STRONG
42
WIFI STRENGTH
FAIR
42
WIFI STRENGTH
WEAK
WIFI STRENGTH
STRONG
Check pack contents:
1. Mains Power Converter
2. RF Wireless Receive
3. LED Light strip
4. RF Remote Control
& CR2025 3V Battery
It is important to check your lights are
working before setting them up.
Please note: you must insert
the lights through loops on
the base of hot tub before
filling up with water.
Before setting up outdoors
1. Setup your CleverSpa® on a solid, level, foundation avoiding sharp objects as they could damage the hot tub.
2. Ensure your CleverSpa® hot tub is plugged into an external mains socket, professionally fitted, with weather
proofing. We DO NOT recommend using an extension cable as this can be a fire risk.
3. Do not place your hot tub in direct sunlight, or over inflate it, as this will cause the hot tub to bulge in
areas as the PVC heats up in the direct sun. This bulging could also put additional stress on the internal
welds leading to a weld failure.
4. During filling, emptying or when in use, water may spill out. Install near to a drainage point capable
of managing the volume of water.
Before setting up indoors
1. Floor must be able to withstand weight of the CleverSpa® + occupants.
2. Floor should be a non-slip, level surface.
3. Before placing your hot tub indoors, ensure suitable drainage is available and can be reached.
Carefully consider the placement of your hot tub before installation.

06
SETTING UP YOUR CLEVERSPA®
Lay groundsheet (A) on a flat,
even surface, clear of
sharp objects.
Unpack CleverSpa®
on groundsheet.
Remove protective plastic
from connectors.
Unscrew cap from
Air Outlet (J).
Push hose (D) into
Inflation Valve (K).
Plug into mains - switch on.
Uncoil cord and RCD/GFCI
plug, located under built-in
control unit.
Screw Hose (D)
on to Air Outlet (J).
Unfold CleverSpa®
ensuring sides are as
upright as possible.
Unscrew outer cap from
Inflation Valve (K). Do NOT
unscrew black inner valve.
Connector Locations:
Air Outlet (J),Inflation
Valve (K) and Water Outlet (L).
J
JJ
D
K
L
K
K
D
Press ‘Inflate/Air Jets’ on
control panel to start inflation
(red light will appear).
A
1
4
7
10
2
5
8
3
6
9
11 12
To aid inflation pull sides upright
and spread out the base.

Remove Hose (D) from
Inflation Valve (K).
Once inflated, press ‘Inflate/Air Jets’
on control panel to stop inflation.
D
KK
J
Screw Filter Cartridge (B)
onto Filter Connector (N).
Add Filter Protector Cover (C)
onto Filter Cartridge (B).
B
D
J
Water Outlet (M)
Filter Connector (N)
Drainage Plug (G).
M
N
G
Set temperature on control panel*
Clip on Top Cover (E) to retain heat.
*See page 10 for full operating instructions.
Double lock clips with
Safety Locking Keys (H).
Screw cap back onto
Inflation Valve (K).
Screw cap back
onto Air Outlet (J).
Do not over tighten.
N
07
C
Unscrew Hose (D)
from Air Outlet (J).
15
18
21
13
16
19
22
14
17
20
23
IMPORTANT NOTE - BEFORE FILLING YOUR CLEVERSPA®
If your CleverSpa® comes with LED lights, please follow the instructions on page 8.
From set up to
maintenance - view
our ‘Clever Clips’
visit:
clevercompany.com/
support/videos
Add water to level.
No higher than ‘MAX’ level.

RF Wireless
Receiver
LED
Light Strip
How to connect
the LED lighting kit
BC
08
HOW TO INSTALL YOUR CLEVERSPA®LED LIGHTING
A
Mains Power
Converter
LIGHT KIT PARTS
LED
Light Strip
C
RF Wireless
Receiver
B
Mains Power
Converter
A
RF Remote Control
& CR2025 3V Battery
D
IMPORTANT! Note the placement of alignment notches
Correct installation of your LED lights is extremely
important. Failure to follow instructions carefully may
result in their early failure. Correct installation will ensure
they stay working every time you use your CleverSpa®.
Ensure lights are not installed too tightly, they must be
fitted loosely, with freedom to move between the retention
loops on the base of the hot tub to allow the lighting strip
to expand when filled with water.
Allow some excess strip across each gap, this will reduce
stress on the lighting.
Failure to do this can reduce the lifespan of your lighting.
Please see image below.
First
Lighting
Loop
Last
Lighting
Loop
Base of CleverSpa®
Start/End lighting
equally spaced
Ensure lighting is not tight between
loops and LEDS face the base
FIT LED LIGHTS LOOSELY TO ALLOW THE CLEVERSPA®TO EXPAND WHEN FILLED.

POWER
On / Standby
CHANGE MODE
Forwards / Backwards
CHANGE SPEED OF LIGHTS
‘+’ Faster / ‘–’ Slower
CHANGE COLOURS
Forwards / Backwards
PRE-SET COLOURS
Select from a range of
pre-set solid colours
BRIGHTNESS
Adjust Lighting brightness (5 levels)
: Increase Brightness
: Decrease Brightness
DEMO MODE
Cycles through pre-set colours & eects
A
B
C
D
E
F
G
A
CG
F
E
D
1. Connect lighting system together as shown on page 8.
2. Remove plastic tape from the battery compartment on the remote.
3. Turn lights on with the power button.
If colours pressed on the remote are activating incorrect colours on the light strip:
1. Ensure the lights are turned on using the red power button.
2. Press the solid Green button once.
3. Switch o the ‘Power’ at the mains for 5 seconds then turn back on.
4. Press and hold the solid green button immediately after turning on.
5. Release the button when the colour changes.
6. Wait 5 seconds for the change to take eect.
INSTRUCTIONS
09
HOW TO USE YOUR CLEVERSPA® LED LIGHTING RF REMOTE CONTROL
INITIAL LIGHTING SETUP
B
+
–

10
OPERATING YOUR CLEVERSPA®
SETTING THE TEMPERATURE
Press ‘SET TEMP/LOCK’ and the numbers on
display screen will start to flash. Increase/
decrease temperature by pressing ‘TEMP UP’
or ‘TEMP DOWN’.
Choose desired temperature, press ‘SET TEMP/
LOCK’ again to confirm. Temperatures can be
set between the range of 5°C to 42°C.
(See safety instructions for recommended
operating temperatures).
INFLATE/AIR JETS
Press ‘INFLATE/AIR JETS’to start air jets - a red
light will appear. Press again and air jets will
stop working - red light will go out.
Air jets stop automatically after 20 minutes.
To reset, wait for 10 minutes and press
‘INFLATE/AIR JETS. Air jets can be stopped/
started any time during their 20 minute cycle.
Air Jets will stop after 20 minutes to avoid
internal pump over-heating.
CONNECTING YOUR CLEVERLINK®APP
1. Check that your CleverSpa®is in a location with strong WiFi
coverage (see page 05).
2. Download the CleverLink®App on your Smart device, from the
App Store or Google Play.
3. Register your account.
4. Follow on screen instructions regarding how to pair CleverSpa
®
to your WiFi.
5. You are ready to go! *Internet access required.
FILTRATION SYSTEM
Press ‘FILTER’, red light will appear, pump will
start to work. Press ‘FILTER’again to stop pump,
red light will go out.
After approx. 168 hours, ‘FC’ will appear on
display screen (flashing), with a warning tone.
Red light will be lit on ‘FILTER’, pump will not
be operational. Heating system will also not
work and red light will be o.
To make sure filtration system is o, press
‘FILTER’. ‘FC’ on display screen will disappear
as well as warning tone. Water temperature will
be displayed, all functions will return to normal.
‘FC’ and warning tone remind user to replace filter.
‘FILTER
CHANGE’
HEATER
Press ‘HEATER’, red light will appear.
Press ‘HEATER’again and heating system
will stop, red light will go out.
When heater system is on, filter system will
switch on automatically to circulate water. When
temperature has reached 1°C above pre-set
temperature, heating system will stop working,
but light will remain on. Filter pump will
continue to operate even when heater
is not functioning.
When water falls 1°C below pre-set temperature,
heating system will automatically heat water
back to 1°C above selected temperature.
Once achieved, heater will stop to allow
temperature to settle at pre-set value.

WATER LEVEL
Water should be filled and maintained between ‘Min’ and ‘Max’ fill lines as indicated on inner wall
of your CleverSpa®
IMPORTANCE OF WATER TREATMENT
You need to regularly monitor and appropriately treat the water in your CleverSpa®.
PEOPLE WITH THE FOLLOWING TRAITS ARE AT HIGHER RISK INCLUDING:
• Diabetes, lung and heart disease • Smokers and heavy drinkers
• Anyone with an impaired immune system • People suering from chronic respiratory or kidney disease.
For more information contact your doctor.
WATER AND LEGIONNAIRES DISEASE?
Legionnaires’ disease can be contracted by inhaling small droplets of water (called aerosols), which
are suspended in the air and contain the bacteria. Certain conditions increase the risk of Legionella if:
• Water temperature in all or some parts of the system is between 20-45°C, which is suitable for
growth of the bacteria.
• It is possible for breathable water droplets to be created and water is stored and/or re-circulated.
• There are deposits that can support bacterial growth providing a source of nutrients for the
organism e.g. rust, sludge, scale, organic matter and biofilms (from the body).
For more information visit: clevercompany.com/support/chemical-maintenance
CLEANING YOUR CLEVERSPA®
Detergent residues, dissolved solids from bathing suits and chemicals will gradually accumulate
in the water. To clean your CleverSpa®, use soap and water then rinse thoroughly.
Please note: do not use hard brushes or abrasive cleaners.
REPAIRING PUNCTURES IN YOUR CLEVERSPA®
If your CleverSpa®is torn/punctured, use repair patches. Completely dry area to be repaired, apply
strong adhesive to repair patch and then cover the damaged area. Smooth the surface to remove
any air bubbles. Leave to dry for 12 hours before using the CleverSpa®.
For more information cleaning and repairing your hot tub visit:
clevercompany.com/support/faqs/cleverspa-faqs
11
MAINTENANCE & REPAIR OF YOUR CLEVERSPA®

12
CLEANING & STORING AWAY YOUR CLEVERSPA®
HOW TO EMPTY YOUR CLEVERSPA®
1. Remove CleverSpa®plug from electrical mains.
2. Unscrew cap from water outlet (L) below pump system of CleverSpa®. Ensure Drainage Plug (G)
is still inserted to prevent unexpected draining.
3. Screw inflation hose (D) onto the water outlet (L) and direct open end of hose appropriately.
4. Remove drainage plug from outlet within floor of CleverSpa®, so water can flow out.
5. Once drained use a sponge to absorb excess water; then operate air jet function for up to
20 minutes (one full cycle) to drain any water and dry out the pipeline. If not completely dry
after first cycle – repeat.
6. When draining has finished, remove inflation hose (D) and replace drainage plug (G) and water
outlet cap (L).
HOW TO DEFLATE YOUR CLEVERSPA®
1. Locate the black two-part air valve (see point 9 on ‘setting up your CleverSpa®).
2. Fully unscrew and remove rapid deflation air valve by turning anti-clockwise (K).
3. Fold hot tub away carefully to remove as much air as possible through the open valve.
STORING YOUR CLEVERSPA®
Make sure all water is completely drained from the CleverSpa®and pump system. This is vital in
extending the life of your CleverSpa®. We recommend the use of a wet/dry vacuum to help blow out/
suck up water from pipes and pump lines. Remove filter cartridge.
CleverSpa®should be placed in bag provided and stored in a dry place, raised o floor and away from
extreme temperatures.
Please note: When not in use, store in a place that is dry and a moderate temperature, as subzero
temperatures can severely damage your CleverSpa®.
WHEN TO CHANGE YOUR CLEVERSPA® FILTER
Keep your CleverSpa® hot tub clean and safe from contaminants. For optimum
performance, unscrew the filter and rinse with clean water after every use to
remove any small particles and residue. The filter is one of the most important
elements to ensure your CleverSpa® hot tub works eectively.
1. Remove filter ‘sock’ protective cover (C) then remove filter (B).
2. Rinse the filter under a cold tap and reuse. Alternatively, machine wash your
filter (place in a pillowcase) to keep it clean and to maintain its performance.
Replace your old filter with a new one if:
• The filter remains soiled after cleaning
• Holes are visible in the paper
• The paper is noticeably worn
3. Replace filter ‘sock’ protective cover (C) over filter (B) and attach to filter connector (N)
by turning it clockwise. Do not over tighten, as this may cause a ‘rattling’ noise.
REMEMBER - CHECK YOUR FILTER EVERY DAY!
To help to keep your water clean, check your filter cartridge every day.
To order filters and chemicals for your CleverSpa®, please visit: clevercompany.com
FILTER
CARTRIDGE (B)
FILTER PROTECTOR
COVER (C)

13
PROBLEMS POTENTIAL CAUSES SOLUTIONS
A1 Air pump too hot
A2 Something wrong with
power box
A3 Air Pump in cooling mode
A1 Unplug system. After air pump has
cooled, insert plug and press air jets
button to activate
A2 Wait for 10 Minutes and restart
A3 Call CleverSpa® Aftersales if does not reset
A1 Temperature is set too low
A2 Dirty filter cartridge
A3 Improper water levels
A4 Heating element failure
A1 Set to a higher temperature (20-42°C)
than current water temperature
A2 Clean/replace filter cartridge
A3 Add water to specified levels
A4 Call CleverSpa® Aftersales if does not reset
A1 Dirty filter cartridge
A2 Something wrong
with power box
A1 Clean/replace filter cartridge
A2 Call CleverSpa® Aftersales if it does not reset
A3 Ask a professional electrician to check
household electrical supply
is functioning correctly
A1 Insucient filtering time
A2 Dirty filter cartridge
A3 Improper water maintenance
A1 Increase filtration time
A2 Clean/replace filter cartridge
A3 Refer to chemical
manufacturer’s instructions
A1 CleverSpa®is torn or punctured A1 Use repair patch provided
SOME TIPS TO HELP YOU TO DIAGNOSE AND RECTIFY COMMON SOURCES OF TROUBLE:
CONTROL PANEL ERROR CODES
Air jet system
is not operating
Heating system
does not operate
Filtering system
does not operate /
Rattling noise when
switching filter on
CleverSpa®leakage
Water not clean
A1 Residual water in the CleverSpa®
will continue to be heated
by residual temperature
A2 Water inlet through filter system
may be blocked
A1 Unplug from mains and wait.
Temperature will start to reduce
and return to normal
A2 Clean the inlet
A3 Call CleverSpa® Aftersales if does not reset
Display temperature
is higher than 42oC,
after stopping
heating function
CORRECT DISPOSAL OF THIS PRODUCT
This marking indicates that this product should not be disposed with other household waste throughout the EU. To prevent possible
harm to the environment, or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse
of material resources. To return your used device, please use the return and collection systems or contact the retailer where the
product was purchased. They can take this product for environmental safe recycling.
TROUBLESHOOTING
Code Cause Solution
FC When filtration system has worked for approx.
168 hours, ‘FC’ will appear on display with a warning
tone. Red light will still be lit on filter, pump will
not be operational. Heating system will not
work, and red light will be out on heater.
SL/HL Temperature Issue
SH Water Temperature Sensor Issue
Check filter and change if necessary.
Once done, press filter again. ‘FC’ error
code will disappear, and warning tone
will stop. Water temperature will be
displayed, all functions will return
to normal.
Contact CleverSpa®Aftersales
on +44 (0) 151 318 6163 or visit:
clevercompany.com
Contact CleverSpa®Aftersales
on +44 (0) 151 318 6163 or visit:
clevercompany.com

14
NEED TO RETURN YOUR CLEVERSPA®? FOLLOW INSTRUCTIONS BELOW:
• Purchased from a UK retailer: Call CleverSpa® Aftersales Team. This will require proof of purchase.
• Purchased from clevercompany.com: If purchased directly from our website, contact us and we
will email instructions to return product. Contact can be made by email or telephone - see warranty
claims section.
When posting items back, clearly mark parcel with order number and full name. Ship unused product,
in original packaging, to address identified in our email. Keep receipt(s) or order number safe, you will
need it as proof of purchase in event of after-sales queries.
POINTS TO NOTE:
• Under Distance Selling Regulations, as a consumer you have the right to cancel your order
and return goods if we are notified within a period of 14 days after delivery of goods.
• You are responsible for shipping products back to us. Use a traceable shipping method.
• If you choose to cancel your order, we require you, the consumer, to pay the cost of returning
the item to us.
• Individual products may be excluded from this guarantee. Check product description before
you place orders.
• We can’t take responsibility for any missing or damaged parcels - take care when returning
orders to us.
If return is due to a product defect, call +44 (0) 151 318 6163 to initiate return.
REFUNDS ON ITEMS PURCHASED THROUGH CLEVERCOMPANY.COM
Once items are received by our warehouse, they will be processed and a refund initiated. Your account
should be credited within a maximum of 10 business days from the time items are received.
DEFECTIVE ITEMS
If your item is defective in any way, consult our FAQ section at clevercompany.com as there may be
a simple solution to the issue. If this does not resolve the issue, please call on +44 (0) 151 318 6163
or email: support@clevercompany.com for assistance.
DAMAGED ITEMS
Purchased from a UK Retailer: If you receive an order from the retailer with obvious shipping damage
- refuse delivery. If delivery has been accepted and then shipping damage is found, follow specific
instructions advised by the retailer.
Purchased from clevercompany.com: If you receive an order with obvious shipping damage - refuse
delivery. If you have accepted delivery and then find shipping damage, please call Clever Company
using contact information included with order.
Save packaging and paperwork for the order. If you dispose of packaging or attempt to return product
without contacting the supplier, you may damage your chances of making a claim.
LIMITS OF RESPONSIBILITY
Clever Company Limited accept no responsibility for misuse or user damage and/or loss of parts
incurred during operation or use of the CleverSpa®.
RETURNS

STANDARD WARRANTY
Warranty relates to all CleverSpa®hot tubs bought in UK and covers the following areas:
• CleverSpa®Pump Heater: 12 months from date of purchase
• CleverSpa®Cover & Liner: 6 months from date of purchase
Warranty is not transferable if the goods are resold after original purchase.
CleverSpa®is designed and manufactured for domestic use only. The Warranty does not extend to any
commercial businesses use.
FREE EXTENDED WARRANTY
If you register within 28 days we will extend your warranty to:
• CleverSpa®Pump Heater: 18 months from date of purchase
• CleverSpa®Cover & Liner: 9 months from date of purchase
REGISTERING YOUR WARRANTY
Visit clevercompany.com/support/warranty/ and complete the form within 28 days of purchase.
Warranty will start from date of purchase which must be verified by proof of purchase.
For up-to-date troubleshooting advice, technical information and FAQs visit clevercompany.com.
WARRANTY CLAIMS
Before making a claim, we may be able to answer your query, simply visit
clevercompany.com/support/cleverspa-faqs.
If FAQs don’t solve the issue and you need to make a claim, visit our website under warranty section,
or contact Aftersales Team by email at: support@clevercompany.com
If you need to make immediate contact our Aftersales Team are available on
+44 (0) 151 318 6163.
Monday – Thursday: 9.00am to 5.00pm
Friday: 9.00am to 4.00pm
15
WARRANTY

Read all chemical instructions carefully and use as directed by
the manufacturer. To purchase CleverSpa®Chemicals and for more
advice on CleverSpa®maintenance, visit clevercompany.com
Clever Company Ltd.
UK Address: Oldgate, St.Michael’s Industrial Estate, Widnes, Cheshire, WA8 8TL.
European Address: Radarweg 29, 1043 NX Amsterdam, Netherlands.
Version: 01
General Enquiries, Returns, Spare Parts, Repairs & Chemical Advice
+44 (0) 151 318 6163 or visit: clevercompany.com
Stabilised Chlorine Granules (500g)
For Disinfecting Hot Tub Water
pH Plus (500g)
For Increasing pH Hot Tub Water
pH Minus (500g)
For Decreasing pH Hot Tub Water
Foam Remover (500ml)
Prevents & Removes Hot Tub Foam
Dip Test (x25)
For testing Chlorine, pH and total Alkalinity
Ensure your CleverSpa®is always working at its best, we recommend
our CleverSpa®Chemical Spa Starter kit:
IMPORTANT!
Before using your CleverSpa®
, please treat the water in accordance
with the chemical maintenance on: clevercompany.com
Table of contents
Other CLEVERSPA Hot Tub manuals
Popular Hot Tub manuals by other brands

Jacuzzi
Jacuzzi SOAKER BATH SERIES Installation and operation instructions

Penner Bathing Spas
Penner Bathing Spas Aqua-Aire Premier Assembly manual

Dynasty Spas
Dynasty Spas 2008 Operator's guide

Kohler
Kohler K-1106 Homeowner's guide

InnovaSpa
InnovaSpa 110-16 owner's manual

PDC spas
PDC spas Vitality SL12s owner's manual