manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Clevertronics
  6. •
  7. Spotlight
  8. •
  9. Clevertronics L10 LIFELIGHT PRO Manual

Clevertronics L10 LIFELIGHT PRO Manual

1942093
V1.0
23 February 2022
Instruction Sheet Template - V1.3 –Updated 20/01/2022
Clevertest and Clevertest Plus
Refer to the supplementary operation guide supplied with the Product.
After Power ON, the Status LED on a Clevertest Plus enabled fitting will display a rapid Green or Red
flashing for a period up to 2 minutes.
4HR: CTP will only test for the 2 hours (first test) and 90 minutes duration. 4 hours testing would only be
facilitated as a Manual Discharge Test.
Zoneworks, HIVE and DATA Monitored Options
Fittings with part numbers -ZW, -HV, -DATA are fitted with Zoneworks communications modules (nodes).
These fittings are monitored using either Powerline Carrier Technology that utilize the power cable to
provide data communication, RF transceiver modules operating in the ISM band or a dedicated data cable
to/from data routers installed on a dedicated data trunk connected to a central Server (can also be
connected via Ethernet/Internet/Fibre). Zoneworks software on the server is used to monitor, coordinate
testing and collate test data from each fitting. Zoneworks Fittings can be commissioned by a single push
of the test switch or by scanning the supplied barcode. The LED Test Switch indicator provides a
multifunction indication of the status of the fitting during testing and normal operation:
Option
State
LED Operation
ZW, HV, DATA
Commissioned
LED on Solid (Green)
ZW, DATA
Un-commissioned
Batt plugged-in: yellow 1s, green 1s
Batt unplugged: red 1s, off 1s
HV
Un-commissioned
With network connectivity
Batt plugged-in: yellow 1s, green 1s
Batt unplugged: red 1s, off 1s
HV
Un-commissioned
Without network connectivity
Batt plugged-in: yellow 250mS, green
250mS, yellow 250mS, green 250mS,
green 1s
Batt unplugged: red 250mS, off
250mS, red 250mS,off 250mS, off 1s
ZW, DATA
Emergency Light Test In Progress
LED flashes at yellow 5s , 0ff 1s
HV
Emergency Light Test In Progress
LED flashes at yellow 1s , 0ff 1s
In the case of the DATA version a 2-way “figure 8” cable and terminal block facilitates the connection to
the DATA network via a multi-drop bus (daisy chain connection). For further information of installation of
a Zoneworks system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl. DATA
version)
DALI EM Option
Luminaires with part numbers having -DALI are fitted with DALI modules (nodes) that facilitate connection
and integration to 3rd Party Lighting Control Systems. Before installing the -DALI luminaire, please confirm
that the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The -DALI
fitting will be addressed and configured into the control system by the Lighting Control System
Commissioning Technicians and not Clevertronics.
State
LED Operation
Commissioned/ Un-commissioned
LED on Solid (Green)
Emergency Light Test in progress
LED flashes at 1s On (Yellow) & 1s Off
“IDENTIFY COMMAND”
Lamp and Status LED Flash for 30 seconds
A 2-way “figure 8” cable and terminal block facilitates the connection to the DALI network. DALI
connections are marked as Da Da.
L10™ LIFELIGHT PRO
Surface Mount Spotlight Emergency
Installation & Maintenance Instruction Leaflet
Victoria (Head Office & Manufacturing)
Website: www.clevertronics.com.au
Email: info@clevertronics.com.au
Phone: +61 3 9559 2700
Fax: +61 3 9559 2799
New South Wales
Phone: +61 2 8805 6400
Fax: +61 2 8805 6444
Queensland
Phone: +61 7 3442 9700
Fax: +61 7 3442 9777
South Australia/Northern Territory
Phone: +61 8 8301 8800
Fax: +61 8 8351 8286
Western Australia
Phone: +61 8 9207 0000
Fax: +61 8 9207 0088
New Zealand
Phone: +64 800 548 448
Designed in Australia to comply with the
requirements of AS2293.3: 2005 and AS/NZS
CISPR15: 2017
NOTE: Standard product codes with this symbol are
enabled with Clevertest Plus capability. Please refer to
the operation guide supplied with the product for details.
Models:
LLIFE-PRO-SMS-SPOT-xx-yy
Testing:
Options:
Manual Test
xx = Blank
4 Hour Battery
yy = 4HR
Zoneworks
xx = ZW
Z/W DATA
xx = DATA
Zoneworks HIVE
xx = HV
DALI Registered.
xx = DALI
Clevertest
xx = CT
(NOTE: -CT Products supplied with the Clevertest Plus Symbol are activated with
Clevertest PLUS capability. Please refer to the operation guide supplied with the product for
details).
Spare Parts:
1530230
BATT:L10 3.3V 5AH. 200mm lead, BRKT
1100869
Lifelight Pro Head Assembly, Ld:280mm,Rnd,LT,Gen 2
1100872
Lifelight Pro Head Assbly,Ld:280mm,Rnd,LT,Gen2,Blk
AUM01370190001
LLIFE-PRO-SMS-CKIT-NP, Lifelight Pro, Control Only, L10, OWC, NP
Important:
It is illegal for anyone, exceptfor a licensed electrician to install or maintain this product. Before installation,
ensure that the electricity supply has been switched off and isolated. Installation must be carried out in
accordance with the relevant Australian and International Standards.
1942093
V1.0
23 February 2022
Instruction Sheet Template - V1.3 –Updated 20/01/2022
Installation:
This LLIFE-PRO-SMS-SPOT Surface Mount Non-Maintained Emergency Luminaire can be installed on
solid or T-BAR ceilings or used to replace an existing unit.
•Locate the installation position.
•Remove the top cover (containing the control gear) from the base plate via the two fixing screws on
the top cover. Disconnect the mains supply cable via the connector between the base and top
cover.
•Refer Images and Dimensions below for the Cut-out Hole and other dimensions.
•Pre-drill mounting holes.
•Mount base plate and use suitable fixings to secure the base plate into the pilot holes.
•Bring in supply cables via the rear entry hole or via the end of the base plate (surface mount
conduit entry).
•Terminate the supply cables to the L, N & E terminals (in the case of the –DALI or –DATA fittings
terminate the DALI or DATA cable to the terminals marked Da Da or DATA).
•Install the top cover, containing the control gear, ensuring to reconnect the control gear assembly
to the connector from the supply terminal block.
•Ensure the Battery is connected.
•Screw the cover to the base plate, and in the case of side/conduit entry remove the knock-out at
the end of the cover to go cover the conduit.
Networking:
When installing the product on a monitored network, (ZONEWORKS, DATA, DALI) simply insert the
relevant Smart Node PCA.
Dimensions:
Testing:
Once connected to the 240V mains supply, the unit must be allowed to charge the battery for at least 24
hours. Conduct the following tests:
•For the first test, the emergency lamp must remain illuminated for at least 2 hours after
disconnection from the mains supply.
•Subsequent tests require the unit to illuminate for at least 90 minutes. The results of all tests are
required to be recorded in a service logbook, which is to be kept on-site at all times. If the unit fails
to remain illuminated for the requisite time, remedial action must be taken to repair the situation
and once completed, the unit must pass a subsequent test. For more specific information, please
refer to the current edition of the AS 2293.3 Standard.
Trouble Shooting:
Below are a list of common problems and their possible causes.
Fault: The Green LED Test Switch indicator is not illuminated.
Check: A.C. is connected and is turned on.
Battery is connected
Test Switch for damage.
Fault: Lamp does not illuminate in emergency mode.
Check: A.C. is connected.
Lamp is correctly inserted.
Battery is connected
Fault: Lamp illuminates in emergency mode, but only stays on for a short period.
Check: Battery has been allowed to charge for at least 24 hours.
Battery for damage.
Caution:
On many building sites, power circuits may be cut off in an uncontrolled and repetitive basis during
construction. As a result, any Exit & Emergency Units, on these circuits, will have their batteries
discharged or “cycled”. The battery in this fitting has been selected to give excellent long-life
performance in a controlled AS2293 testing environment. Excessive battery cycling will reduce through-
life performance and may lead to premature battery failure. Battery warranty claims, as a result of such
abuse, are specifically EXCLUDED from Clevertronics warranty terms.
Warranty:
For Product Warranty information and Terms and Conditions of Sales please refer to our website
http://clevertronics.com.au/terms-conditions-sale-australia-nz/
Mains entry hole

Other Clevertronics Spotlight manuals

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMS-SPOT Installation and operating instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SMS-SPOT Installation and operating instructions

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SPOT Installation and operating instructions

Clevertronics

Clevertronics L10 LIFELIGHT PRO LLIFE-PRO-SPOT Installation and operating instructions

Popular Spotlight manuals by other brands

Anslut 422-353 operating instructions

Anslut

Anslut 422-353 operating instructions

Portfolio 00860 manual

Portfolio

Portfolio 00860 manual

NEBO NEB-LSP-0014 Use and care guide

NEBO

NEBO NEB-LSP-0014 Use and care guide

ACME LED-707 user manual

ACME

ACME LED-707 user manual

GlacialLight GL-SD60 Series user manual

GlacialLight

GlacialLight GL-SD60 Series user manual

LIVARNO LUX 285643 Operation and safety notes

LIVARNO LUX

LIVARNO LUX 285643 Operation and safety notes

HAMPTON BAY 10238 Use and care guide

HAMPTON BAY

HAMPTON BAY 10238 Use and care guide

IMG STAGE LINE PARL-40DMX instruction manual

IMG STAGE LINE

IMG STAGE LINE PARL-40DMX instruction manual

IMG STAGE LINE PARL-183RGB instruction manual

IMG STAGE LINE

IMG STAGE LINE PARL-183RGB instruction manual

Show Tec ORDERCODE 30645 user manual

Show Tec

Show Tec ORDERCODE 30645 user manual

DS Produkte 12310889 instruction manual

DS Produkte

DS Produkte 12310889 instruction manual

LIVARNO LUX 40114 Assembly, operating and safety instructions

LIVARNO LUX

LIVARNO LUX 40114 Assembly, operating and safety instructions

LIVARNO LUX 304540 Assembly, operating and safety instructions

LIVARNO LUX

LIVARNO LUX 304540 Assembly, operating and safety instructions

Factory Method ZING manual

Factory Method

Factory Method ZING manual

mawa wi4-ab-2ov Mounting manual

mawa

mawa wi4-ab-2ov Mounting manual

LIVARNO home 898-S-2 Operating and safety instructions

LIVARNO home

LIVARNO home 898-S-2 Operating and safety instructions

Tracon Electric STLBT10W user manual

Tracon Electric

Tracon Electric STLBT10W user manual

TOOLCRAFT 2229245 operating instructions

TOOLCRAFT

TOOLCRAFT 2229245 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.