Technical data
Shutdown procedure
•For normal isolation, the Closomat toilet can be
turned off using the integrated switch. To carry out
any servicing, the unit MUST be isolated at the
mains feed.
Bathroom/shower room
installations
•The Closomat toilet must not be in direct line
with the shower spray. Some form of partition
between shower and the Closomat toilet is
advisable to prevent any water spraying directly
onto the equipment.
•A shower should not be used in conjunction with
the Closomat toilet i.e. under no circumstances
must a user shower whilst seated on the
Closomat toilet.
Water services (WRAS approved)
•It is essential that the entering water
is cold.
•We would recommend water supply isolated via
isolation valve.
•Water supply can be from storage vessel or mains
(‘Grey Water’ MUST NOT BE USED).
•Boiler Capacity: 1.7 litres.
•Water rate: min. 8 l/min.
max. 0.8 PMa (8 bar)
•Cistern capacity: 6 litres.
Overflow
•The Closomat toilet has an internal overow
which discharges into the W.C. pan through the
ush valve.
Soil connection
•Relevant soil connector to be sourced by installer.
•Soil connections suitable for Closomat toilet;
S-Trap (vertical fall) wall to centre of pipe from
70mm-230mm max. P-Trap (horizontal) oor to
centre of pipe 200mm max.
•The Closomat toilet is suitable for all turned trap
outlets, through purpose made removable side
covers on lower level.
The Closomat toilet MUST
be installed by a competent or
qualied person.
Explanation of symbols
•Safety instructions in this manual are identied by
symbols. The safety instructions are introduced
by signal words, which express the extent of the
hazard/risk.
•In order to prevent accidents, personal injury,
property damage and guarantee maximum user
safety, follow the safety instructions without fail
and exercise caution.
Description of equipment
•The Closomat toilet is an electrically operated
shower (wash and dry) toilet designed to provide
the operator/user with a hygienic solution to toileting.
Start-up procedure
•To enable a warm washing cycle operation
the Closomat toilet must be switched on.
Each Closomat toilet has its own isolation switch.
To switch the unit on, the location for each switch
is as follows;
•Palma Vita – Right hand side of unit, at the base
of the cistern cover, through a Perspex screen.
•Lima Vita – Right hand side of unit, at the base
of the cistern cover, through a Perspex screen.
•Once switched on, the water will reach core
temperature within 5 minutes. It is advised that
to maintain the core temperature in readiness for
use, the unit be left switched on at all times.
Electrical services
•To avoid the risk of electric shock, this equipment
MUST only be connected to a supply mains with
protective earthing by a competent or qualied
person.
Mains isolation
•All electrical appliances must be installed in
accordance to the relevant regulations associated
with the country it is within. To conduct any form
of repairs or servicing it is recommended that
a mains isolation device be located in the vicinity
of the unit.
•220/240v single phase AC supply is required,
(loading 10A, maximum power 1300 watts).
The Closomat Lima toilet is supplied with a 3
core cable attached and MUST NOT be removed
or replaced. A fused spur is required for isolation.
•Spur outlet to be located in accordance with
current I.E.E. Regulations (Current Edition).
•No modication of this unit is allowed other than
by the manufacturer.
•Closomat has IPX4 rating.
IEC 60417-5840
TYPE B
APPLIED PART
IEC 60878
Safety 01b
Follow operating
instructions

3
Flushing
Press either elbow pad whilst standing
for conventional ush.
Washing
Press elbow pad whilst seated and hold
down for approximately 10-15 seconds,
ushing and warm water washing will
then take place.
Drying
Warm air drying automatically follows
when elbow pad is released.
Further notes
•No permanent hand rails or other obstructions
should be tted across the front or top of the unit.
The outer casing has to be pulled upwards and
forward to remove for servicing purposes.
•Unit not rated for altitude. 2000m is the
maximum.
•This application requires an earth connection.
•Environmental conditions – operating ambient
room temperature maximum = 60°C.
Environmental conditions
The Closomat toilet is rated to IPX4 and can be
installed and operated within a typical shower/toilet
room.
Classification
Medical Device Class 1 certied EN60601-1-1:
2007/AC: 2010.
Cleaning information
•The use of bleach products is not advised due
to the exposed stainless metal parts associated
with the washing device. (tarnishing may occur).
•The Closomat toilet washing device is designed
to self cleanse during and after every use.
Normal cleansing of the bowl and outer covers
is required.
Maintenance and frequency of
serviceable parts
•The Closomat toilet is self-sufcient but it is
recommended that a competent experienced
Service Engineer carry out a safety check and
an annual service of the internal workings,
to extend the Closomat’s life.
Risk associated with the waste of
equipment after service life
•At the stage the unit is not repairable it can
be discarded to any appropriate recyclable
plant. There are no immediate risks to the
environment.
User guide

4
Lima Vita planning data and
service requirements
•Safe working load:
•Overall dimensions:
804mm high x 451mm wide x 730mm deep
120Kg
18.5St
190Kg
30St
82Kg
12.5St
60Kg
9St
75Kg
11.5St
349Kg
55St
300Kg
47St
200Kg
30St
LIMA
220-240V, 50hz
10A IPX4
Tel: +44 0800 374 076
www.clos-o-mat.com
Wall Template
Located in
Document Box

Installation
7 Unhook the xing adjuster brackets
from the frame.
6Loosen and remove the front screw.
8 Repeat unhooking on opposite side
ensuring cover is free.
5 Gently lift the cistern housing upwards
(small arrow) and then pull it forward
and off (large arrow).
3 Carefully loosen and pull out the
covering cap on the cistern housing.
4 Loosen the screw of the cistern housing
completely, but do not remove it.
IMPORTANT: Please retain all packaging until the installation is complete. Protect all oor
surfaces when handling the Closomat. DO NOT slide the Closomat across the ooring.
Pull away cover once adjuster brackets
are loose.
2 Remove the seat – Open the lid. Press
and hold the seat hinges together with
both thumbs whilst rmly gripping
the outer edges of the seat. Now pull
upwards sharply.
1 To lift the Closomat use the porcelain
ushing edge at the front and the steel
frame at rear, and lift it out of the
bottom of the packing.
5
➞
➞
➞
9

Installation (cont.)
11 Ensure the installation template is level.
10 Locate installation template against
desired wall.
16 Loosen the nuts on the threaded pins of
the mounting plates on both sides with a
13mm wrench in anticlockwise motion.
15 Figure 15 shows the assembly plate.
17 Remove assembly plate (arrow).
14 Once to size, use the soil pipe connector
to mark its position on the required wall.
12 Once the installation template is
secured, use to drill the wall as directed.
13 Using the desired soil pipe connector
pushed against the Closomat, measure
the required length.
18 Attach assembly plate to the wallviathe
holes you have already drilled. Alignthe
assembly plate horizontally with a spirit
level. Tighten the four screws on the lift
system with a 19mm wrench in clockwise
motion. Remove the spirit level.
6
➞

Installation (cont.)
20 Lift the toilet on the frame with two
persons and remove the transport
supports (held on with adhesive tape).
Carefully lower the toilet to the oor.
Pull the electrical cable out of the toilet
and leave it hanging down.
19 Figure shows:
A. assembly plate B. soil pipe
24 Push and rmly x the soil pipe
connection to the wall and Closomat.
Now connect the water to your inlet
and the electrics via the socket you have
installed.
21 Carefully lift the toilet on the frame with
two persons and hang it on the threaded
pins of the assembly plate as follows:
• The threaded pins must be positioned
in the hole of the frame.
•The drain pipe must be placed on the
drain of the toilet. Make sure that the
drain of the toilet is inserted into the
drain pipe of the lift system. Make sure
that the toilet is seated down to the
mechanical stop on the threaded pins
on both sides.
22 Place washers on the threaded pins on
the left and right of the toilet. Screw on
the nuts on the threaded pins on the left
and right of the toilet. Gently tighten the
nuts of the threaded pins on the left and
right of the toilet with a 13mm wrench
in clockwise motion.
23 Loosen the counternut on the left
support screw with an 8mm wrench
in anticlockwise motion. Unscrew
the support screw by hand until
the mechanical stop. Re-tighten the
counternut on the left support screw
with an 8mm wrench in clockwise
motion. Loosen the counternut on
the right support screw with an 8mm
wrench in anticlockwise motion.
Unscrew the support screw by hand
until the mechanical stop. Tighten the
counternut on the right support screw
with an 8mm wrench in clockwise
motion.
A
B
7

Test procedure
1 Fill the Closomat with water and switch
on mains electricity. Locate the on/off
switch and click to the on position ‘I’,
the switch will illuminate blue. Check all
joints for leaks.
7 Should the water pressure need
adjusting to suit the user, locate the
pump situated on the right hand side
of the Closomat. Hold down or release
the pump pressure spring slide by either
tightening or untightening the adjacent
holding nut. Clockwise will increase the
pump pressure, whereas anticlockwise
will achieve the opposite.
4 Simultaneously pressing the right hand
seat hinge hull and the operation bar
will activate the warm water wash, run
the wash for approximately 30 seconds
to ensure water pressure is constant.
8
5 Should the wash splutter during the
wash cycle described in step 4, the
douche system may need purging to
remove any potential air-lock, generated
during the unit’s transit/installation.
To do this insert the special tool supplied
hook end into the recess at the bottom
of the douche arm (arrow).
➞
6 Pull out the douche arm using the special
tool with force against the spring pressure
until the arm reaches its maximum stop.
Hold the douche arm with a free hand
once fully extended, rotate the tool and
locate the tool into the slot and recess in
the douche arm to hold in this extended
position (arrow). Run wash cycle to purge,
once wash is constant remove tool and
allow the douche arm to retract.
➞
2 Allow approximately 5 minutes for the water to heat in the boiler. Check the circuit board,
the boiler light will be permanently illuminated red while the water is being heated tothe
operating temperature. As the water temperature approaches the required operating
temperature the light will ash red. If the boiler light does not illuminate, check the safety
stat has not tripped (see inset) by pressing ‘click’ to reset.
➞
Check procedure
1 Ensure electrical supply is connected to unit, and switched on: check that correct fuse is tted.
2 Ensure water supply is turned on and that the ball valve is allowing water to enter the cistern
and shutting off at correct level. Ensure ow of water is adequate to keep douche supplied.
3 Ensure rear of seat is depressed.
4 Keep elbow pad depressed until water runs cold. Keep seat depressed while hot air is operating.
5 Trouble-shooting guide available direct on our website: www.clos-o-mat.com
6 Ensure joints are dry and have not been disturbed during installation.
note
• Foot switch, hand switch or remote switch, if tted, will operate exactly as elbow pads.
• Douche temperature and pressure are preset at factory, and adjustments should only
be carried out by Closomat engineers familiar with the equipment.
3 IMPORTANT
Place Perspex
screen over pan
to contain water
spray during the
following steps.
note
• The Closomat will not function automatically if the seat switch is not depressed.
• The unit should be switched on electrically at all times when in service.

Finishing the installation
3 Replace and tighten the front screw.
1On completion of installation and test
procedure, replace bowl cover.
2 Hook brackets into position. Where
necessary adjust to provide a water tight
seal, adjust the rising block until the seals
are tight against the porcelain.
8 Complete the installation by testing the
Closomat works by again depressing
the seat and holding in one of the elbow
pads ensuring the perspex guard is in
place.
7 Replace the seat by locating the hinge
pins in the corresponding holes in the
pan – press the seat rmly to secure its
position.
6 Carefully tighten and push in the seat
buffer on the cistern housing.
4Now locate the cistern cover in place,
making sure the window in the right
hand displays the on/off switch.
5 Tighten the screw of the ush tank
housing completely.
Please advise us of
installation address
in order that we
can arrange the
commission
and activate the
12-month
guarantee.
9

Side entry pipes
1 With a sharp implement, remove the side
panel screw covers.
2 Remove the screw and set aside. 3 Remove the side panel.
4 Install the side entry pipe scribing the side panel to suit each location,
Ret the side panel on completion.
10
10
Armrest
Left Hand
Stainless
Pivot Bearing
Pivot Block
End Cap
Pivot Block
Nylon
Washer
50mm Dia. Belville
Washer
Pivot Block
Washer
Inserted on to
Pivot Block
Nylon Trim
Washer
HOLE CUTTING
POSITION FOR
OUTER COVER
IS MEASURED
TO CENTRE OF
ARM BRACKET
ON FRAME
M20 Bolt
Important
Bolt must not
rotate when the
armrest is
moved.
Important
Ensure Belville Washer is
assembled correctly with the
dome towards the bolt head
Hole
diameter
76mm
minimum
78mm
maximum
Lima integrated fold-down support arms installation

11
Lima integrated fold-down support arms technical data
11
How to drill holes in the cover if armrests are tted
Support foot
Lima Vita’s supplied with support arms are also supplied with an adjustable stainless steel support foot.
It is advised that this is tted and adjusted to ensure the toilets’ stability.
Measure 367mm from rear of
unit to centre of arm xing point
Measure from
upper side of porcelain
pan to centre of arm
xing point approx.
207mm – 210mm

CM36/December 2018
www.clos-o-mat.com
lUK design and development
lUK manufacturing
lUK customer support
Building 1 •Brooklands Place •Brooklands Road •Sale •Cheshire •M33 3SD • Fax: 0161 973 2711
Table of contents
Other closomat Toilet manuals
Popular Toilet manuals by other brands

American Standard
American Standard CONCEPT Cube TF-2704 installation manual

BIOLAN
BIOLAN ECO Instructions for installation, use and maintenance

Thetford
Thetford C260 Series user manual

KELISS
KELISS T162A Series instruction manual

Silent Venus
Silent Venus SVP600 Installation & maintenance

Kohler
Kohler K-22241K Installation and care guide