eSENSE Outdoor™ carbon dioxide transmitter Technical
Specifications
General Performance
Compliance with ...............................................EMC directive 89/336/EEC. RoHS directive 2002/95/EG
Operating Temperature Range ........................-22 to +115 °F
Storage Temperature Range ............................-4 to +122 °F1
Operating Humidity Range ...............................0 to 95% RH (non-condensing)
Operating Environment .....................................Outdoor
Warm-up Time ..................................................< 1 min. (@ full specs < 15 minutes)
Sensor Life Expectancy ....................................> 15 years
Maintenance Interval ........................................no maintenance required
Self Diagnostics ................................................complete function-check
Electrical
Power Input ......................................................24 VAC/VDC ±20%, 50 Hz (half-wave rectifier input)
Power Consumption .........................................< 1 Watt average (Heater Off)
Connection screw terminal A ............................4 x 1,5 mm2for power input (G+, G0) and voltage outputs (OUT1,
OUT2)
CO2Measurement
Sensing method ................................................Infrared (NDIR) waveguide technology with Automatic Baseline
Correction (ABC) and passive gas diffusion (no moving parts)
Response Time (T1/e) ........................................< 30 sec. @ 30 cc/min. flow rate, < 3 min. diffusion time
Repeatability......................................................± 20 ppm ± 1 % of reading
Accuracy3 ..........................................................± 30 ppm ± 3 % of reading
Annual Zero Drift3 ............................................< ± 10 ppm
Pressure Dependence ......................................+1.6% of reading per kPa deviation from normal pressure 101.3kPa4
Outputs
Output signal terminal CO25
OUT1 linear conversion range...........................0 - 10 VDC for 0 - 2 000 ppm.
OUT2 linear conversion range...........................4 - 20 mA or 2 – 10VDC for 0 - 2 000 ppm.
...........................................................................D/A resolution 10 bits, 10 mV
D/A conversion accuracy...................................± 2 % of reading ± 50 mV
Electrical characteristics....................................ROUT < 100 Ohm, RLOAD > 5 kOhm (Heater Off)
Note 1: After long-term storage a zero calibration is recommended.
Note 2: All corrosive environments are excluded.
Note 3: Accuracy is defined after zero calibration or after minimum 23 days of continuous operation. The tolerance of the
span gas (2% unless otherwise requested) and test gas adds to the total uncertainty.
Note 4: For reference see TN-025 "on pressure sensitivity".
Note 5: The specifications are valid for the output load connected to Ground G0.