Coelbo SWITCHMATIC 1 Setup guide

1
SWITCHMATIC 1 / 1 plus
SWITCHMATIC 2 / 2 plus
SWITCHMATIC 3 / 3 plus
ADVANCED SETTINGS
Risk of damaging the pressure assemblies and/or the plant.
Risk by electric shock.
Risk for people and/or objects.
EN

2
1. GENERAL
Read carefully the instructions before installing this unit. Verify
the technical characteristics of the motor in order to assure the
compatibility with the device.
2. DESCRIPTION (diagram A)
SWITCHMATIC 1 is an electronic pressure switch with integrated
digital manometer. It manages the start and stop of a single-pha-
se pump up to 2.2kW (3 HP) (SW1-2). Cut-in and cut-out pressures
are easily adjustable through the users control panel.
Wiring is analogous to the traditional electromechanical switch.
It can operate as a diferential pressure switch and as reverse pres-
sure
switch.
Unit SWITCHMATIC 2 in addition to all the features of the basic
SWITCH- MATIC includes instantaneous reading of current drawn.
This patented system controls and manages the overcurrent, dry-
run operation and fast-cycling.
Unit SWITCHMATIC 2 in addition to all the features of individual
assembly includes the option to be synchronized to another unit
SWITCHMATIC 2 managing and protecting 2 pumps operating in
cascade with alternated starting sequence. The SWITCHMATIC 3
unit is ideal for a control panel as it has a dry contact output.
3. OPERATING CHARACTERISTICS (diagram C)
• Adjustable cut-in and cut-out pressures.
• Integrated digital pressure gauge with bar and psi indication.
• Inner pressure transmitter.
• Dry-run protection:
• Through minimum adjusted height for basic SWITCHMATIC
1/3.
• Through the instantaneous current consumption in case of
SW2.
• Overcurrent protection.
• Overvoltage protection.
• ART Function (Automatic Reset Test). When the device has
stopped the pump by the intervention of the dry-running
protection system, the ART tries, with scheduled basis, to re-
start the pump in order to restore the water supply. See “ART.
Automatic reset function“. Must be activated in the step 6 of
the ADVANCED MENU (Ar1).
• Fast cycling: when the hydropneumatic tank has lost too much
air and, consequently, frequent start-stop cycles are produced
this alarm is activated and is delayed the start of the pump.
Activated (rc2).
• Manual start push-button (ENTER).
•3 operation modes: diferential, reverse and synchronized.
• Control panel with 3-digit display, LED indicator lights and
push-buttons.
• Volt-free contact for monitoring the alarms displayed in the
screen (only version in-out).
• Connections for a level switch, its use is optional (in-out mo-
dels only).
• Available settings:
• Stand-by mode.
• Minimum period between fast cycles.
• Start and stop delay.
4. TECHNICAL CHARACTERISTICS
• Rated motor power: 0,37-2,2 kW (SW1-SW2)
• Power supply: ~1 x 110-230 V (SW1-SW2)
~1 x 48-230 Vac/Vdc (SW3)
~1 x 24 Vac/Vdc (SW3 24V)
• Electric outlet: Dry contact (SW3)
• Nominal pressure 1MPa/10bar (plus:13bar)
• Frequency: 50/60Hz
•Max. current: 16 A, cos ≥ 0.6 (SW1-2-3)
10 A, cos ≥ 0.6 (SW3 24V)
• Protection degree: IP55
• Max water Temperature: 50ºC
• Max environment Temperature: 60ºC
• Cut-in range (start pressure) 0,5÷7 bar (v. plus=11 bar)
• Cut-ot range (stop pressure) 1÷8 bar (v. plus=12 bar)
•Max. diferential (Pstop-Pstart) 7,5 bar (v. plus=11,5 bar)
•Minimum dif. (Pstop-Pstart) SW: 0,5 bar
SW2 synchro: 1 bar
• Factory setting (start/stop) 3/4 bar
• Hydraulic inlet G1/4” Fem. - NPT 1/4” Fem.
• Net weight (without cables) 0,3 kg
5. HYDRAULIC INSTALLATION (diagram A)
SWITCHMATIC units must be threaded to a tting G1/4” male
at the pump´s outlet.
Before connecting the SWITCHMATIC verify that the hydraulic
system is properly installed, especially if the hydropneumatic tank
is pressurized.
6. ELECTRIC CONNECTION (diagram B)
The electric connection must be perormed by qualied per-
sonal in compliance with regulation of each country. Before
doing manipulations inside the device, it must be disconnected
from the electric supply.
Wrong connection could spoil the electronic circuit.
The manufacturer declines all responsability in damages
caused by wrong connections.
When carrying out the electrical connection it is compulsory to
use a diferential switch ohigh sensitivity: I = 30 mA (clase A o
AC). It is compulsory to use a magnetothermic switch adapted at
the motor load.
Check if power supply is between 115-230V (SW1-2).
If you have purchased the unit without cables follow diagram B:
• Use cables type H07RN-F 3G1 or 3G1,5 with section enough to
the power installed.
• Do the pump connection U, V and (SW1-2) or C1, C2 and
to the control panel (Only SW3)
• Do the power supply connection L1, N and . (SW1-2-3) or
24V + and - (SW3 24V)
• The earth conductor must be longer than the others. It will be
the rst one to be mounted during the assembly and the last
one to be disconnected during the dismantling. The earth
conductors connections are compulsory!
• (Only version in-out) The device has a volt-free contact for
monitoring the alarms displayed in the screen originated by
irregularities or problems of the system. See Diagram C for
connection.
• (Only version in-out) There is a level switch input in the auxiliary
circuit. See Diagram C for connection.
7. CONTROL PANEL (diagram D)
The meanings othe diferent control panel elements are sum-
marized on the following tables, where:
• O means lit LED light.
•( ( O ) ) means slow-ashing.
•(((O))) means ast-ashing.
DISPLAY ACTION
OPERATION
MODE
Is showed on screen instantaneous pressure or
instantaneous current consumption
ADJUSTMENT
MODE
Is displayed on screen the adjusted start pressure
blinking.
Is displayed on screen the adjusted stop pressure
blinking.
Is displayed the adjusted rated current blinking
(only SW2).
ALARM MODE Is displayed the alarm code
STAND-BY MODE Are displayed 3 ashing dots
BASIC CONFIGU-
RATION MODE
Is displayed the sequence obasic conguration
parameters
ADVANCED
CONFIGURATION
MODE
Is displayed the sequence oadvanced congura-
tion parameters
LEDS STATE MEANING
bar
OIt indicates the instantaneous pressure in bar
((O)) It indicates the instantaneous pressure in bar
+pump operating (only SW1/SW3)
psi
OIt indicates the instantaneous pressure in psi
((O)) It indicates the instantaneous pressure in psi
+pump operating (only SW1/SW3)
A
(only SW2)
OIt indicates the instantaneous current con-
sumption in Ampere units
( ( O ) ) Pump ON
START O Is displayed the start pressure
((O)) Adjusting start pressure
STOP O Is displayed the stop pressure
((O)) Adjusting stop pressure

3
P-BUT-
TON TOUCH ACTION
click!
From state ON: unit OFF.
From state OFF: the pump starts and
keeps operating until reaching Pstop.
From any conguration MENU: the
parameter value is accepted.
HOLD
DOWN
From state ON: unit OFF.
From state OFF: the pump starts and
keeps operating until the push-button
is released.
click! Pstart is displayed on the screen for 3
seconds.
3” Pstart adjustment mode.
click! Pstop is displayed on the screen for 3
seconds.
3” Pstop adjustment mode.
click!
Is displayed on the screen instantaneous
current consumption.
If it is already displayed then we switch
to instantaneous pressure view.
3” Rated current adjustment.
8. STARTUP (diagram C)
Before starting the device please read the previous sections,
especially “Hydraulic Installation” and “Electrical connec-
tion”.
Follow next steps:
1. Only for type SW2 set the pump rated current intensity value.
- Press during 3 seconds.
- The current intensity value is displayed on screen, LED A
lights up and display is ashing.
- By mean of and is adjusted the rated current reected
in the characteristics plate of the motor. See Note 1.
- Press for validation.
2. Start the device by pressing .
3. Set the cut-in (start) pressure:
- Press during 3 seconds.
- The start pressure value is displayed on screen, LED START
lights up and display is ashing.
- By mean of and is adjusted the start pressure from 0,5
to 7 bar (+ version=11 bar).
- Press for validation.
4. Set the cut-out (stop) pressure:
- Press during 3 seconds.
- The stop pressure value is displayed on screen, LED STOP
lights up and display is ashing.
- By mean of and is adjusted the stop pressure from 1 to
8 bar (+ version=12 bar).
- Press for validation.
5. The unit is ready to operate but more optional adjustments can
be set through basic and advanced MENUS. See the next chapter.
Remark 1: it is important to introduce exactly the rated
current specied on the nameplate othe pump.
9. BASIC MENU +(diagram C)
- Press simultaneously + during 5 seconds.
- By mean of or the values can be changed.
- Press for validation.
- The parameters sequence is:
it TYPE SYSTEM REACTION FACTORY
SETTING
1 BAR P We can select the pressure units
displayed beetween bar and psi. bar
2 rc0 rc2
Fast-cycling alarm:
- rc0: alarm unabled.
- rc1: activated, when hammering is
detected it is delayed the start
in order to protect the pump.
- rc2: alarm is activated and the
pump is stopped upon detec-
tion.
rc2
2.1 r.01 r.99
Only if fast-cycling alarm has been
activated in the previous step
(rc1&rc2). It can be choosed the
maximum time period between 3
consecutive starts that will be con-
sidered fast cycling (between 1 sec.
and 99 sec.)
3 seconds
3 Sb0 Sb1
Stand-by mode activated (Sb1), for
low power consumption, or unabled
(Sb0).
Sb0

4
10. ADVANCED MENU + +
- Press simultaneously + + during 5 seconds.
- By mean of or the values can be changed.
- Press for validation.
- The parameters sequence is:
it TYPE SYSTEM REACTION
FAC-
TORY
SET-
TING
1nc no
Select the operation MODE as a con-
ventional pressure switch (nc = norma-
lly closed) or reverse (no = normally
open). *see remark 3
nc
2E00 E01/02
(Only Switchmatic2).
Select the operation mode Individual
(E00) or Master/Slave (E01/E02) in
case of be assembled in groups of two
pumps.
E00
2.1 d.05 d.1
(Only Switchmatic 2).
Sets the minimum gap between Pstart
1 and Pstart 2 and/or Pstop 1 and
Pstop 2.
d.05
3ct0 ct9
Sets a time delay between 0 and 9
seconds to the start (is not available in
synchronized operation mode).
ct0
4dt0 dt9 Sets a time delay between 0 and 9
seconds to the stop. dt0
5AE1 AE0/
AE2
(Only in Switchmatic 2)
Select AE0 to dissable dry run alarm
by current consumption. To have a dry
run protection, the minimum pressure
value must be set.
Select AE1 to enable dry run alarm
with auto-learning mode. In this mode,
the SW2 will learn the real consump-
tion of the pump.
Select AE2 to enable dry run alarm
without auto-learning mode. In this
case, when the pump consumes a 40%
less of the value set as rated current,
the dry run alarm will appear.
6Ar0 Ar1
(Only Switchmatic2)
Activation of the automatic restore
system ART (Ar1) o disable (Ar0).
Ar0
7P0.0 Px.x
It allows setting a minimum operating
pressure under which the device would
determine dry-running operation. It is
very usefull in the basic model SWIT-
CHMATIC where there is no reading of
current intensity drawn. See Note 2.
0 bar
0 psi
7.1 t05 t99
Set the time period between 5 and 99
seconds below the minimum operating
pressure that will be considered a dry-
running operation.
20”
8c10 c30
(Only Switchmatic2)
It allows setting a % of nominal current
above which the device will activate
the overcurrent protection.
c20
9tE0 tE1
tE2
(Only Switchmatic2)
It manages the external inputs of the
in-out auxiliary circuit (on request).
tE0: means disabled.
tE1: minimum level contact input. It
would trigger alarm A21.
tE2: external input. It allows to acti-
vate/deactivate the device by means
of an external contact, for example a
timer. If tE2 is enabled and the external
contact deactivates the equipment, the
display shows “EL-”
tE0
9.1 co1 co0
Only in case of tE1 activated:
co1: nc (normally closed contact).
co0: no (normally open contact)
co1
10 H00 H99
Anti-ooding conguration.
If activated, it stops the pump after
programmed time (in minutes) of
continuous operation.
Disabled (H00), 1 minute (H01) ... 99
minutes (H99).
H00
11 r rS1 If we change rS0 to rS1 and push EN-
TER default values are restored. rS0
Remark 2:
Basic SWITCHMATIC 1/3 can only detect dry-running
operation through the minimum pressure. This means that
plumber must determine the water column of the installa-
tion, the start pressure of the pump and place the minimum
pressure below the start pressure.
It can also occur that pumping system is running out of its
curve so that the pump is unable to provide the minimum
pressure because the ow requirement is excessive. In this
case SWITCHMATIC 1/3 would activate a alse dry-running
alarm.
Ithese concepts are not clear, it is preerable not congure
this protection or install the SWITCHMATIC 2 with accurate
and easy setting of dry-run detection.
Remark 3:
By choosing “no” (normally open) it will operate as an auxi-
liary pressure control element in the suction of the pump. It
will restart when the suction pressure reaches the congu-
red PStart.
Example: - PStop: 0,9 bar
- PStart: 1,2 bar
11. SYNCHRONISATION (ONLY FOR SWITCHMATIC 2)
SWITCHMATIC 2 can be synchronized to another unit SWITCH-
MATIC 2 managing and protecting 2 pumps operating in cascade
with alternated starting sequence. Next steps must be followed:
1. GO TO ADVANCED MENU: + +
-Instep 2: select E01 in a unit (this one will be the master) and
select E02 in the other unit (this one will be the slave).
- In step 3: select identical parameters of gap between pressu-
res d.XX. This is the diference beetween the starting pressure
omain and auxiliary pumps, it is also the diference beetween
stop pressures of both pumps.
2. Press repeatedly until exit the ADVANCED MENU.
3. SET identical cut-in and cut-out pressures in both units.
To optimize the synchronization, the minimum diference
between the start and stop pressures must be at least 1 bar.
4. Press in order to disable the units. Is displayed “OFF”.
5. Press again in both units in order to activate the synchroni-
zation.
Remark 4: ater 10 cycles the unit congured E01 will display
pressure and the unit congured E02 will display current in
Amps.

5
12. PRESSURE SENSOR CALIBRATION
In case of wrong lecture of the pressure sensor it can be adjusted
again.
For the pressure sensor calibration is necessary to have a pressure
gauge in the installation. Proceed following next steps:
ZERO REGULATION
1. Open the taps living the hydraulic net without pressure.
2. Press simultaneously the buttons and until the display
show 0.0 ashing.
3. Press to validate.
FULL SCALE
1. Start the pump and close all the taps to pressuri-
ze the installation and reach the cut-out pressure.
(If the pump does not start, please hold the button to
reach the cut-out pressure)
2. Press simultaneously the buttons and till the display
ashes with a gure.
3. Adjust the pressure with the arrows push-buttons until the va-
lue on the display maches with the pressure reading.
4. Press to validate.
Remark 5: pressure sensor decalibration should not be a nor-
mal event. Iit is requently repeated contact the technical
service.
13. REGISTER OPERATION DATA AND ALARMS + +
(ONLY FOR SWITCHMATIC 2)
- Press simultaneously + + during 5 seconds.
- Press to advance in the REGISTER.
- The DATA sequence is:
MESSAGE DESCRIPTION SCOPE
rEC
HF xxx Controller operating hours 0-65535
HP xxx Pump operating hours 0-65535
CF xxx Operating cycles
Number of start-stop cycles.
0-999999
Cr xxx Number of connections to the
power supply.
0-65535
A01 xxx Number of A01 alarms. 0-999
A02 xxx Number of A02 alarms. 0-999
A04 xxx Number of A04 alarms. 0-999
A05 xxx Number of A05 alarms. 0-999
A11 xxx Number of A11 alarms. 0-999
APM xxx Number of over-pressure
alarms (---).
0-999
rPM x.x Maximum registered pressure.
rSt ENTER -> EXIT.
+ -> All the alarms are
restored except the opera-
tion data.
14. WARNINGS AND ALARMS
COD. DESCRIPTION SYSTEM REACTION
A01
O
DRY-RUN-
NING
(Only for
SWITCHMA-
TIC 2)
When is detected a dry-run operation
the pump is automatically stopped. By
mean of ENTER the normal operation
can be manually restored.
((O))
After the activation of the dry-running
alarm if the Automatic system reset
(ART) is enabled, a rst attempt at 5
minutes and then an attempt every 30
minutes for 24 hours is performed in
order to restore the normal operation.
This alarm can also be reset manually
with the ENTER push-button. If the
alarm persists ater 24 h we nd a
denitive alarm.
A11 O
DRY-RUN-
NING
(BY MINIMUM
PRESSURE)
Is displayed during normal operation
if the pressure is below the minimum
pressure (Px.x) - previously set - during
a period (txx) - also previously set - in
the ADVANCED MENU.
If at any time the pressure exceeds the
minimum pressure, the operation is
restored automatically and the alarm
is cleared.
Normal operation can also be restored
manually by pressing ENTER.
A21 ((O))
DRY-RUN-
NING
(BY EXTERNAL
LEVEL INPUT)
Only if tE1 has been activated in the
advanced programming menu.
The alarm is displayed on the screen
when the oat switch detects a low
level of water in the suction tank,
stopping the operation of the pump. It
is automatically restored when there is
water again.
A02
O
OVERLOAD
(Only SW2)
Overcurrent alarm is activated when the
nominal pump current is exceeded.
4 automatic reset attempts prior to the
nal alarm are perormed.
During the attempts display will show
current.
Normal operation can also be restored
manually by pressing ENTER.
((O))
A04 (((O))) FAST CYCLING
(Hammering)
This alarm can be unabled or activated
in the BASIC MENU. The alarm is
activated when 3 consecutive cycles
occur in a range lower than the set time
(between cycle and cycle).
If it has been activated rc1, this alarm
does not stop the normal operation but
are added 5 seconds to the start delay
in order to protect the electric pump.
If it has been activated rc2, the pump
is stopped.
To RESET the normal operation press
ENTER.
A05 O
DAMAGED
PRESSURE
TRANSMITTER
CONTACT WITH YOUR SUPPLIER.
15. EC STAMENT OF COMPLIANCE
COELBO CONTROL SYSTEM, S.L. States, on our own responsibi-
lity, that all materials here with related comply with the following
European Directives:
- 2014/35/EU.
- 2014/30/EU.
- 2011/65/EU+2015/863/EU.
Name: - SWITCHMATIC 1 /1+
- SWITCHMATIC 2/2+
- SWITCHMATIC 3/3+
Standards : EN-60730-2-6, EN-60730-1, EN-61000-6-1, EN-61000-
6-3, IEC-60730-1, IEC-60730-2-6
F. Roldán Cazorla
Director Técnico
04/05/2016
COELBO CONTROL SYSTEM, S.L.
Ctr de Rubí, 288 - P.I. Can Guitard
08228 Terrassa - BARCELONA (SPAIN)
16. CLASSIFICATION AND TYPE
According to IEC 60730-1 and EN 60730-1 this unit is a control
sensor device, electronic, independent assembly, programming
type A with action type 1B (microdisconnection). Operating value: I
<20% I learned. Pollution degree 2 (clean environment). Rated im-
pulse voltage: cat II / 2500V. Temperatures for ball test: enclousure
(75) and PCB (125).

6
~1x48-230Vac/
Vdc
DIAGRAM A INDIVIDUAL
SYSTEM (ONLY SW2)
SWITCHMATIC 1/2 SWITCHMATIC 3
MANDATORY USE
OF PRESSURE TANK
MANDATORY USE
OF PRESSURE TANK
MANDATORY USE
OF PRESSURE TANK

7
M
DIAGRAM C: AUXILIARY CIRCUIT IN-OUT
SW1-2
SW3
SW1/2
SW3
C1 C2
C1 C2
30mA
(+) (-)
L U
N V
CONTACTS RATING
Max. switching voltage:
230VAC / 220 VDC
Max. switching power:
62,5VA / 30W
OUT
DIAGRAM B: POWER SUPPLY AND MOTOR
~1x48÷230Vac/Vdc (SW3)
~1x110÷230Vac (SW1/2)
Press to release
Cables:
2
max. 1,5 mm
2
min. 0,2 mm
MAX VOLTAGE
24V
IN

8
SWITCHMATIC 1 / 3
116
77,550
75
G1/4"F
(NPT 1/4" F)
116
77,550
75
G1/4"f
(NPT 1/4" f)
SWITCHMATIC 1 / 2 SWITCHMATIC 2 / 3 in-out
SWITCHMATIC 2
V14_07/2022
DIAGRAM D
DIMENSIONS
Other manuals for SWITCHMATIC 1
2
This manual suits for next models
5
Table of contents
Other Coelbo Control Unit manuals
Popular Control Unit manuals by other brands

Alfalaval
Alfalaval Unique 7710 instruction manual

Contec
Contec Conprosys CPS-MC341-ADSC1-111 Reference manual

Blue Technix
Blue Technix TIM-UP-19k-S3-Spartan 6 user manual

MYPV
MYPV AC Thor 9S Assembly instructions

Alfalaval
Alfalaval 741 Series instruction manual

Data Video
Data Video MCU-100P instruction manual