8.4 Synchronising Panoramas without DMX 512 signal
Multiple Panorama Cyc 1800 Architectural units may be interconnected in the absence of DMX 512 signal, operating
simply via the inbuilt programs within the Panorama unit.
All the Panorama Cyc 1800’s thus connected will operate simultaneously with one unit acting as MASTER and all
subsequent units as a SLAVE.
The Panorama Cyc 1800 Architectural which is to act as master should be selected according to ease of access for pro-
gramming purposes. Control signal is transmitted from Master to slave via 2 core ø0,5 screened cable.
Connection is serial, daisy-chaining units using the DMX IN and DMX OUT sockets located in the base of the Panorama
Cyc 1800 Architectural.
1) insert the cables through the PG 9 entry sockets.
2) Connect as shown in the diagram below.
Connect the projectors by using the signal
from the “master” to connect to the first
slave, then from the first slave to the
second, and so on to a maximum of 10
projectors.
ATTENTION:Ensure that all data conductors are isolated from one another and the metal housing of the connector.and
under no circumstances should any connection be made from the signal cable or the screening to the metal support of the
projector. Test that the cable is isolated prior to powering up the projector.
Should you need to connect more than 10 units we recommend that you use a suitable dmx
splitter box to achieve this.
These units are usually opto-isolated and may amplify and repeat the signal as required.
We recommend that any unused PG 9 entry sockets be sealed as previously described to main-
tain the integrity of the Panorama Cyc 1800 Architectural’s weather protection rating.
Prior to closing the base of the unit, we recommend that all the internal settings be carried
out (sections 10 to 14); do not forget to set the DMX address, any automated settings, auto-
mated programs and any other settings via the multifunction display panel as access to the
panel is only available when the cover is off.
Once these settings have been carried out, all internal junction boxes may be closed up to
seal them off as shown below.
master
slave
out
in
made in italy by
coemar spa
Castel Goffredo (mn)
serial number
Alimentazione: collegare SOLO a coemar ballast 1800W.
Per accedere alle connessioni di potenza e segnale riferitevi al manuale di istruzioni.
Main power: connect to coemar ballast 1800W ONLY.
To acces to mains and signal connections pls. refer to the instructions manual.
ATTENZIONE!
ALTA TENSIONE ALL'INTERNO DELL'APPARECCHIO.TOGLIERE TENSIONE
PRIMA DI EFFETTUARE QUALSIASI OPERAZIONE.
UNA BUONA CONNESSIONE DI TERRA E' ESSENZIALE.
WARNING!
HIGH VOLTAGE INSIDE. DISCONNECT FROM POWER SUPPLY
BEFORE OPENING. A GOOD GROUND CONNECTION IS ESSENTIAL.
pin1: gnd
pin2: data-
pin3: data+
pin4: optional-
pin5: optional+
dmx 512
in out
3
2
1
AUto auto sequence
MA.SLlink between fixture
AUSP auto speed
AUdL auto delay
diMM dimmer
coLr colour speed
LAMP lamp function
tESt single ch. test function
rESE reset
rAtE DMX speed
HoUr working time (in hour)
LIFE lamp life (in hours)
on
MASt master
0000 time speed (m=min. s=sec.)
0000 number of frames
Strd standard
Strd standard
Strd standard
oFF
slav slave
01 to ...
01 to ...
SLoU slow
SLoU slow
Strd standard
t01 to t04
Set functions (function display)
menu enterenter
1dimmer 2cyan 3magenta 4yellow 5function
Individual channel assignement
factory set main at:
208V 230V 240V115V
out
in
made in italy by
coemar spa
Castel Goffredo (mn)
serial number
Alimentazione: collegare SOLO a coemar ballast 1800W.
Per accedere alle connessioni di potenza e segnale riferitevi al manuale di istruzioni.
Main power: connect to coemar ballast 1800W ONLY.
To acces to mains and signal connections pls. refer to the instructions manual.
ATTENZIONE!
ALTA TENSIONE ALL'INTERNO DELL'APPARECCHIO.TOGLIERE TENSIONE
PRIMA DI EFFETTUARE QUALSIASI OPERAZIONE.
UNA BUONA CONNESSIONE DI TERRA E' ESSENZIALE.
WARNING!
HIGH VOLTAGE INSIDE. DISCONNECT FROM POWER SUPPLY
BEFORE OPENING. A GOOD GROUND CONNECTION IS ESSENTIAL.
pin1: gnd
pin2: data-
pin3: data+
pin4: optional-
pin5: optional+
dmx 512
in out
3
2
1
AUto auto sequence
MA.SLlink between fixture
AUSP auto speed
AUdL auto delay
diMM dimmer
coLr colour speed
LAMP lamp function
tESt single ch. test function
rESE reset
rAtE DMX speed
HoUr working time (in hour)
LIFE lamp life (in hours)
on
MASt master
0000 time speed (m=min. s=sec.)
0000 number of frames
Strd standard
Strd standard
Strd standard
oFF
slav slave
01 to ...
01 to ...
SLoU slow
SLoU slow
Strd standard
t01 to t04
Set functions (function display)
menu enterenter
1dimmer 2cyan 3magenta 4yellow 5function
Individual channel assignement
factory set main at:
208V 230V 240V115V
Ad altri Panorama Cyc Architectural (Slave)
Connect to other Panorama Cyc Architectural (Slave)
Schermatura Schermatura
Ø 0,5
Ø 0,5
Al prossimo
Panorama
1
2
3
Non collegato
Panorama 1800 Architectural
Slave
3 2 1
Dmx 512 Out
3 2 1
Dmx 512 in
Panorama 1800 Architectural
Slave
321
Dmx 512 Out
3 2 1
Dmx 512 in
Panorama 1800 Architectural
Master
321
Dmx 512 Out
3 2 1
Dmx 512 in
Ø 0,5
Ø 0,5