Comunello CU-24V-1M User manual

CU - 24V - 1M
INSTALLATION AND USER’S MANUAL
Control unit
comunello.com
ISTRUZIONI D’USO E DI INSTALLAZIONE
INSTALLATIONS-UND GEBRAUCHSANLEITUNG
INSTRUCIONS D’UTILISATION ET D’INSTALLATION
INSTRUCCIONES DE USO Y DE INSTALACION
ИНСТРУКЦИЯ ПО МОНТАЖУ Cod. 91300174 Rev. 01 - 30.04.15

2COMUNELLO ®Copyright 2014 - All right reserved
ID level
L1 1LED 1
L2 2LED 1 +LED 2
L3 3LED 1 +LED 2 +LED 3
L4 4LED 1 + LED 2 +LED 3 +LED 4
L5 5LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6 6LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7 7LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV Menù 3 FLASHES
RIASSUNTO DEI MENÙ
ID LED
L1 FOTOTEST ON OFF
L2 PEDESTRIAN TIME ON OFF
L3 DECELERATION OFF ON
L4 REMOTE CODE PGM ON OFF
L5 RELEASE STROKE ON OFF
L6 SLAM LOCK ON OFF
L7 COURTESY LIGHT ON OFF
LEV LEV 1 FLASH
ID LED
L1 SOFT STOP ON OFF
L2 SOFT START ON OFF
L3 DS 1 IN OPEN ON OFF
L4 HOLD-TO-RUN ON OFF
L5 FOLLOW ME ON OFF
L6 PAUSE FLASHING ON OFF
L7 ALWAYS CLOSE ON OFF
LEV MENU 2 FLASHES
ID LED
L1 DIR Open to left Open to right
L2 STEP BY STEP Step-by-Step Automatic
L3 CODE TX Code entered No code
L4 CONDO ON OFF
L5 MOTOR TIME Programmed time 30 sec.
L6 PAUSE TIME With automatic closure Without automatic closure
L7 AUTO PROGRAM ON OFF
LEV MENÙ ON
MAIN MENÙ
EXTENDED MENÙ 1
EXTENDED MENÙ 2
EXTENDED MENÙ 3

3
COMUNELLO ®Copyright 2014 - All right reserved
ITALIANO
FIG. 4
TABELLA CONNESSIONI CAVI AG01 - WIRES CONNECTION TABLE AG01
BASIC 24V – SLIDING GATE (CU 24V 1M)
ID Description Cable type Lenght (1m to 20m) Lenght (20m to 50m)
1Main power supply
FG7 CEI 20-22
CEI EN 50267-2-1
2x1,5mm2 2x2,5mm2
2Flashing light 2x0,5mm2 2x1,0mm2
4A , 6A Photocell TX 2x0,5mm2 2x1,0mm2
4B , 6B Photocell RX 4x0,5mm2 4x1,0mm2
5 Key selector 3x0,5mm2 3x1,0mm2
3 Antenna RG58 max 20m

SEL SET
F2
SPEED SENS
1 ST
2 ND
L N
ANTENNA
PULSANTE APRI-CHIUDI (N.O.)
PUSCH BUTTON (N.O.)
ALIMENTAZIONE FOTOCELLULE
PHOTOCELL POWER
24V 5W
FINECORSA APRI (N.C.)
END OPEN (N.C.)
+
FINECORSA CHIUDI (N.C.)
END CLOSE (N.C.)
FOTOCELLULA - DS (N.C.)
ATTIVA IN CHIUSURA
PHOTCELL - DS (N.C.) ACTIVE IN CLOSING
FOT+
GND
STOP
GND
GND
FCA
DS1
GND
PP
ANT
ANT+
FCC
CN2
LAMPEGGIANTE
FLASHING LIGHT
24V 4W
CN1
M
MOTORE
MOTOR
24V
TRASFORMATORE
TRANSFORMER
230/21.7V - 7.5A
CN5
CN4CN3
L24
L24
M1+
M1
LINEA
POWER SUPPLY
230V 50Hz
+
BATTERIA TAMPONE
BACK-UP BATTERY
F1
2 ND BATT
BLOCCO (N.C.)
STOP (N.C.)

5
COMUNELLO ®Copyright 2014 - All right reserved
ITALIANO
FORT like below:
Led “opening direction” OFF: OPENS TO THE RIGHT
Inner side view
OPENING DIRECTION: 1 MOTOR CONFIGURATION
FORT
FORT like below:
Led “opening direction” ON: OPENS TO THE LEFT
Inner side view
RED ON M1+ BLACK ON M1-

SALIENT: DO NOT CHANGE the conguration!
Opens to the left, closes to the right (left prole view, as in the image).
SALIENT
BLACK ON M1+ RED ON M1-

13
COMUNELLO ®Copyright 2014 - All right reserved
ENGLISH
CU - 24V - 1M
INSTALLATION AND USER’S MANUAL
Fratelli Comunello S.p.A.
Company with certied Quality Management System
UNI EN ISO 9001:2008.
(Certicate n° 50 100 11235 Rev. 01)
EC DECLARATION OF COMFORMITY:
The undersigned Mr. Luca Comunello, representing the following manufacturer,
Fratelli COMUNELLO Spa
Via Cassola 64, 36027 Rosà (VI) – Italy
DECLARES that the equipment described below:
Description: Electronic control unit
Model: CU 24V 1M
Is in compliance with the provisions set down in the following directives:
• 2004/108 EC Directive (EMC Directive)
• 2006/95/CE Directive
and that all the rules and/or technical specications shown below have been applied:
EN61000-6-2 + EN61000-6-3
EN62233:2008
EN301489-1 + EN301489-3 + EN300220-2
EN60335-1:2002
and the following amendments.
Last two digits of the year in which the EC marking has been afxed 14
Rosà (VI) – Italia
01-09-2014
and he also declares that it is not allowed to commission the device until the machinery where it will be incorporated or whose it will
become a component will have been identied and will have been declared in compliance with the conditions of the 2006/42 EC Directive
and with the national legislation that transpose it.
Mr. Luca Comunello
Fratelli Comunello Legal Representative

14 COMUNELLO ®Copyright 2014 - All right reserved
PRESCRIPTIONS
• The control unit is not equipped with a device for
disconnection of the 230 V~ power supply line.
It is therefore the responsibility of the installer
to t a disconnection device in the electrical
system. The disconnection device must be
composed of a category III overvoltage all-pole
circuit breaker. This device must be positioned
in consideration of the need to be protected
against inadvertent reconnection in compliance
with the requirements of EN 12453 point 5.2.9.
Wiring of the external electrical devices to the
control unit must be carried out in compliance
with the prescriptions of EN 60204-1 as
amended by EN 12453 point 5.2.7. The
maximum diameter of power feeding cables is
14 mm; xing of power feeding and connection
cables must be assured by tting cable glands,
which can be supplied as optionals.
• The power input cables must be of the
standardized exible type with polychloroprene
sheath (H05RN-F) having minimum conductor
size of 1 mm2.
• During the installation operations, take care to
use cable with double insulation only (sheathed
cables) for both of mains voltage connections
(230V) and extra-low voltage connections
(SELV). Use exclusively plastic cable trays,
separated for mains voltage wiring (230V) and
extra-low voltage wiring (SELV).
• The extra low voltage conductors must be
physically separated (at least 4 mm in air) from
the mains voltage wires, or shall be adequately
insulated with extra insulation with a thickness
of at least 1 mm.
• Upstream of main supply, install a device that
ensures the complete omnipolar disconnection
(cut-off switch) of the power supply, with a
contact opening gap of at least 3mm in each
pole. These disconnecting devices shall be
places in the power supply wiring in compliance
with the installation standards and must be
directly connected to the supply terminals.
• When drilling the outer case to insert the power
and connection cables and when tting the
cable glands, take care to install all the parts
in a manner that maintains the IP protection
characteristics of the box unchanged as far
as possible. Ensure the cables are xed in a
stable and secure manner.
• The rear of the box is equipped with knockouts
for wall xing (knockouts for xing holes using
anchor bolts or holes for xing with screws).
Take all the measures required to ensure the
installation procedures do not affect the IP
rating.
• If required, a pushbutton panel for manual
control of the gate must be installed in a position
such as to ensure the user is not placed in
danger.
• The operator utilized to move the gate must
be in compliance with the prescriptions of EN
12453, point 5.2.7.
• Power Supply output D.S. must be used for
photocells. Alternative uses of this output are
not permitted.
• At each operating cycle, the control unit
can test the photocells operation to ensure
protection against failure of anti-crushing
protective devices according to Category 2 in
compliance with the prescriptions of EN 12453
point 5.1.1.6. It follows that if the safety devices
are not connected or are faulty, operation of
the control unit will be inhibited.
• The device can be used by children no older
than 8 years old and people with reduced
physical, sensory or mental capabilities, or
lack of experience or without the required
knowledge, but only under surveillance or after
having received instructions about the safe
use of the device and the hazards inherent in
it. Children should not play with the device.
Cleaning and maintenance should not be
carried out by children without supervision.
For correct operation of the radio receiver section,
when using two or more control units it is good
practice to install them at a minimum distance of
3 metres from one another.
All operations that require the control unit box to
be opened (connection of cables, programming,
etc.) must be carried out by expert personnel at
the time of installation. For all further operations
that require the box to be re-opened.
IMPORTANT INFORMATION FOR USERS
• The device must not be used by minors or
psychologically-physically differently abled
persons unless they are supervised or duly
instructed on the operation and methods of
use.
• Do not let children play with the device and
keep the remotes out of their reach.
• IMPORTANT: keep this instruction manual and
comply with the safety prescriptions set down
herein. Failure to comply with the prescriptions
may cause damage and serious accidents.
Frequently examine the system to identify any
signs of damage. Do not use the device if repairs
are required.

15
COMUNELLO ®Copyright 2014 - All right reserved
ENGLISH
TECHNICAL SPECIFICATIONS
Back-up Battery input: 24 V 7A/h max.
Flashing light output: 24 V 4 W max.
Operator outputs: 24V 1 x 50 W max.
Photocells power supply: 24V 5 W max.
Working temperature:
-20 ÷ + 50°C
Radio receiver: 433 Mhz
Transmitters: 18 Bit or Rolling Code
Max TX codes stored in memory: 120 (CODE or PED CODE)
Board dimensions: 100x105 mm.
Maximum power consumption 150W
PRELIMINARY CHECKS
• Check that the product in the pack is intact and in good condition.
• Check that the place of installation is suitable and in compliance with the
minimum dimensions shown in FIG. 1.
INSTALLATION
• Drill the box in the four corners and then x the control unit to the wall
(FIG. 2).
• Drill a hole in the underside of the box for the cable inlet. (FIG. 3)
The use of cable glands is recommended.
ELECTRICAL CONNECTIONS
CN1:
BATT+24V: +24V Back-up Battery input
BATT-24V: –24V Back-up Battery input.
LAMP+24V: +24V Flashing Light Output.
LAMP-24V: –24V Flashing Light Output.
MOT1+: Operator 1 + Output.
MOT1-: Operator 1 – Output.
CN2:
STOP: Emergency stop input (NC)
GND: Common GND input
FOTO+: Photocells Control and Power Supply (24V 5W).
GND: Photocells Control and Power Supply (GND).
FCC: Operator Closing Limit Switch Input (NC).
GND: Common GND input
FCA: Operator Opening Limit Switch Input (NC).
DS1: Safety Device Input (NC).
GND: Common GND input
PP: Pedestrian Pushbutton open-close command input (NO).
ANT-: Antenna Ground Input.
ANT+: Antenna Hot pole input.
CN3:
L: 230 V~ line input (phase).
N: 230 V~ line input (neutral).
TRANSFORMER CONNECTIONS
CN4 1st:
1: 230 V~ Transformer Primary Winding Input.
2: 230 V~ Transformer Primary Winding Input.
CN5 2nd:
1: Transformer SEC 1 Output 21.7V 7.5A no-load voltages.
2: Transformer SEC 1 Output 21.7V 7.5A no-load voltages.
FUNCTIONAL CHARACTERISTICS
AUTOMATIC OPERATION:
When either the remote or the low voltage pushbutton panel is used to
control the gate, operation is as follows:
the rst command opens the gate until motor time elapses or until the gate
reaches its opening limit position; the second command closes the gate; if
another command is transmitted before motor time has elapsed or before
one of the two limit stops has been reached, the control unit reverses the
movement direction during both opening and closing.
STEP-BY-STEP OPERATION:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the rst command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement. Another command causes the gate to start moving again in the
opposite direction.
Step-by-step 1 operations:
When either the remote or the low voltage control pushbuttons are used to
control the gate, operation is as follows:
the rst command opens the gate until motor time or until the gate
reaches its opening limit position; the second command closes the gate;
if another command is transmitted before motor time has elapsed or
before one of the limit stops has been reached, the control unit stops the
movement during both opening and closing. Another command causes the
gate to start moving again in the opposite direction.
AUTOMATIC CLOSING:
The control unit can be set up to close the gate automatically without
sending any additional commands.
The selection of this type of operation is described in Pause time
programming mode.
PEDESTRIAN OPENING:
By means of the remote (CODE P. LED lit) the remote control makes it
possible to drive the Operator for a programmable time, typically to allow
pedestrian access.
EMERGENCY STOP INPUT:
The control unit allows the connection of an emergency stop pushbutton
(NC). Pressing this pushbutton irrespective of the current operating mode
of the control unit will cause immediate stopping of the gate movement. An
additional gate movement command will be valid provided the emergency
stop input is deactivated and, in any case, the control unit will execute the
gate opening cycle with 5 seconds preashing.
IMPORTANT: Jumper this input if it is not to be used.
PHOTOCELLS:
Photocells can be powered by and connected to the control unit in
accordance with directive EN 12453.
Tripping of the photocells during opening is disregarded, while during
closing it causes reversal of the direction of movement.
To allow operation in compliance with EN 13849-1, Category 2 a photocell
test is performed before each movement. The control unit enables the
movement only if the test is passed; if it is not, the control unit inhibits
all movements and an alarm condition is signalled by blinking of all the
programming LEDs on transmission of each command.
OBSTACLE DETECTION (SENS):
The electronic control unit is equipped with a “SENS” trimmer, completely
managed by the microprocessor, for adjustment of the opposing Force
required to detect the presence of an obstacle.
The adjustment can be made with a trip time from a minimum of 0.1
seconds to a maximum of 7 seconds.
IMPORTANT:
• If limit switches are connected to the control unit detection of an obstacle
will always result in movement reversal during closing and reversal for 2
seconds during opening.
• If there are no limit switches connected to the control unit detection of an
obstacle will always result in movement reversal during closing (except
in the nal 5 seconds of the movement, when it will cause a Stop) and
reversal for 2 seconds during opening (except in the nal 5 seconds of
the movement, when it will cause a Stop).
Obstacle detection system also works with automations without
encoder.
OPERATOR SPEED ADJUSTMENT (SPEED):
The electronic control unit is equipped with a “SPEED” trimmer for
operator speed adjustment, completely managed by the microprocessor.
Adjustment can be performed in a range of between 50% and 100% of

16 COMUNELLO ®Copyright 2014 - All right reserved
maximum speed.
Initial starting torque can be set for each movement by feeding the operator
at full power for 2 seconds, even if operator force control is enabled. Note:
initial starting torque is disabled automatically if the Soft Start function is
enabled.
Important: If the “SPEED” trimmer is adjusted the self-learning
procedure must be repeated because the movement and deceleration
times may change.
DECELERATION:
The operators deceleration function is used on gates to prevent the moving
leaves from slamming at speed into the limit stops at the end of the opening
and closing strokes.
During Operator Time programming (see Main menu) the control unit also
allows programming of deceleration in the desired points (immediately
before full opening and full closing); in addition, using the “DELAY” trimmer
the force intensity can be adjusted during the deceleration phase.
1. OPENING DIRECTION (DIR):
In the default conguration the control unit is set with “OPEN TO RIGHT”
logic (seen from the operator side, with operator installed to the right of
the sliding leaf); if the “OPEN TO LEFT” logic must be enabled (seen from
operator side, operator installed to the left of the sliding leaf), proceed as
follows: use the SELECT key to select the blinking DIR LED and press the
SET key: the OPEN DIRECTION LED will light steady and programming will
be completed. Repeat the procedure if you wish to restore the previous
conguration.
2. STEP-BY-STEP:
In the default conguration the control unit is set with “Automatic” operating
logic enabled (LED n2 off); if the “Step-by-Step” operating logic is required
(LED n2 on), proceed as follows; use the SELECT key to select blinking
LED n2 and then press the SET key: LED n2 becomes steady on and
programming will be completed.
If the “Step-by-Step 1” operating logic is required, repeat the operation
above described, by pressing the SEL key twice instead only one (to obtain
the quick blinking of LED. Repeat the procedure if you wish to restore the
previous conguration.
3. TX CODE: (Remote control code)
Up to 120 remote controls with different codes of either the xed or the
rolling code type can be saved on the control unit.
Programming:
Programming of the transmission code is performed as follows: use the
SELECT key to select blinking LED L3. Press SET once; the LED will change
its blinking mode (longer 1 0 1 0) to show that the rst level is being saved.
On sending the selected code with the desired remote, the CODE LED will
remain steady on to indicate that programming has been completed.
To save the code for pedestrian opening / single leaf proceed as follows:
use the SELECT key to select blinking CODE LED L3. Press SET twice
consecutively; the LED will change its blinking mode (1 1 0 1 1 0) to show
that the pedestrian code is being saved. On sending the selected code
with the desired remote CODE LED L3 will remain steady lit to indicate that
programming has been completed.
If all 120 codes have been saved, repeating the programming operation will
cause all the programming LEDs to start blinking to signal that no further
codes can be saved.
Deletion:
Use SELECT to go to LED L3; activate blinking of the code to be deleted
(CODE or PEDESTRIAN identied by the respective blinking); press and
hold down SET for > 5 s. After this interval the LED will switch off for 2
seconds and the procedure is completed. If all CODE and PEDESTRIAN
codes are deleted, the LED will remain off.
If only PEDESTRIAN codes remain stored, the LED blinking mode will
change (1 1 1 1 0 1 1 1 1 0).
Rule of the rst saved Remote control:
When programming remotes the following rule is applied: if the rst remote
to be saved is of the rolling code type, the receiver will subsequently
accept only rolling code remotes, thus providing enhanced anti-intrusion
security; if the rst remote to be saved is a xed code type, the receiver will
subsequently accept both xed code remotes and rolling code remotes,
although only the xed part of the latter will be controlled (thus effectively
relinquishing the security of the rolling code system).
4. CONDO:
The Condominium function means that during the opening movement or
during the pause time the control unit will not respond to commands sent
by Pushbuttons or remotes. In contrast, during the closing movement a
command sent by the Pushbuttons or the remotes will reverse the direction
of movement. This operating mode is invaluable when the automation
includes a loop detector.
In the default conguration the control unit is set with the Condominium
function disabled; if the Condominium function is required, proceed as
follows: use the SELECT key to select blinking LED L4 and then press
the SET key: LED L4 will light steady and programming will be completed.
Repeat the procedure if you wish to restore the previous conguration.
5. MOTOR TIME (Programming of the motor run time of the
operators with max 4 minutes):
The control unit is factory set with preset motor time of 30 seconds
without deceleration. If the motor time of the operators must be changed,
programming must be carried out with the gate closed as follows: use
the SELECT key to select blinking LED L5 and then press the SET key
momentarily; the operator will start the opening movement; when the
desired deceleration starting point is reached press the SET key again; at
the same time the operator will decelerate and reach the desired position;
press SET to terminate the opening cycle. Thereafter LED L5 will start
blinking rapidly; now repeat the motor time and deceleration programming
procedure for the closing cycle. If you do not require the control unit to
perform the deceleration, during programming, when the open-close cycle
has been completed press the SET key twice consecutively rather than
just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
6. PAUSE TIME: (Programmazione tempo chiusura aut. 4 min. max.):
The control unit is factory set with automatic closing disabled. If you wish
to enable automatic closing proceed as follows: use the SELECT key to
select blinking LED L6 and press the SET key momentarily; now wait for
a time equivalent to the desired time interval; press the SET key again
momentarily and at the same time the automatic closing time will be saved
and LED L6 will remain steady on. If you wish to restore the initial condition
(no automatic closing) select blinking LED L6 and then press the SET key
twice consecutively in a time period of 2 seconds. The LED will switch off
and the operation will be completed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
7. AUTOMATIC PROGRAMMING:
The control unit provides allows Automatic Programming (SIMPLIFIED).
First bring the gate leaves to an intermediate position, use the SELECT
key to select blinking LED L7 and then hold down the SET key; the
control unit executes the Auto programming procedure by performing a
complete opening and closing cycle (keep the SET key pressed until Auto
Programming is completed). During the Auto Programming procedure,
the Deceleration cycle is set automatically at approximately 15% of the
complete cycle.
During Automatic Programming, instead of the SET key on the control unit
you can use the button on the remote, providing the remote has been
saved beforehand.
EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 1, proceed as follows: select blinking LEV LED and press SET once.
The LED will start blinking. This means there will be 30 seconds to select
the functions of Extended Menu 1 using the SELECT and SET keys; once
an additional 30 seconds have elapsed the control unit reverts to the main
menu.
L1 FOTOTEST ON OFF
L2 PEDESTRIAN TIME ON OFF
L3 DECELERATION OFF ON
L4 REMOTE CODE PGM ON OFF
L5 RELEASE STROKE ON OFF
L6 SLAM LOCK ON OFF
L7 COURTESY LIGHT ON OFF
LEV LEV 1 FLASH
1. PHOTOCELLS TEST:
The control unit is factory set with the photocells test disabled; proceed

17
COMUNELLO ®Copyright 2014 - All right reserved
ENGLISH
closing, 1 extra second at the maximum power or at the power selected
with the “FORCE” trimmer, in such a way as to ensure positive engagement
of the gate lock, if installed. If you wish to enable the Slam Lock function
at maximum power, proceed as follows: make sure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L6 and then
press the SET key: LED L6 becomes steady on and programming will be
completed. If you wish to enable the Slam Lock function at the power set
with the “FORCE” Trimmer, repeat the operation described by pressing the
SELECT key twice (LED L6 will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial conguration.
7. PREFLASHING/COURTESY LIGHT:
The control unit is factory set with the Preashing and Courtesy Light
functions disabled. If you wish to enable the Preashing function proceed
as follows: make sure you have enabled Extended Menu 1, use the SEL key
to select blinking LED L7 and then press the SET key: the LED becomes
steady on and programming will be completed. If you wish to enable the
Courtesy Light function, repeat the operation described above, pressing
the SET key twice (the LED will blink rapidly) rather than once. Repeat the
procedure if you wish to restore the initial conguration.
Preashing Operation: The 24 V~4W max. Flashing Light output will
always switch on 3 seconds before the gate starts the closing operation.
Courtesy Light Operation: The 24 V~4W max. Courtesy Light output
will switch on for 3 minutes whenever an opening command is transmitted
EXTENDED MENU 2
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 2, proceed as follows: select blinking LED no. 8 and press SET
twice. The LED will start blinking alternately 1 1 0 1 1 0 1 1 0. This means
there is a period of 30 seconds to select the functions in Extended Menu 2
using the SELECT and SET keys and then, after a further 30 seconds, the
control unit will revert to the main menu.
L1 SOFT STOP ON OFF
L2 SOFT START ON OFF
L3 DS 1 IN OPEN ON OFF
L4 HOLD-TO-RUN ON OFF
L5 FOLLOW ME ON OFF
L6 PAUSE FLASHING ON OFF
L7 ALWAYS CLOSE ON OFF
LEV MENU 2 FLASHES
1. SOFT STOP:
The control unit is factory set with the Soft Stop function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L1
and press the SET key; at the same time LED L1 becomes steady on and
programming will be completed. With this function enabled at the end of the
movement the control unit will reduce operator force to zero gradually in a
2 second interval. Repeat the procedure if you wish to restore the previous
conguration.
2. SOFT START:
The control unit is factory set with the Soft Start function disabled. If you
wish to enable the function, proceed as follows: ensure you have enabled
Extended Menu 2 and then use the SEL key to select blinking LED L2
and press the SET key; at the same time LED L2 becomes steady on
and programming will be completed. With this function enabled at the start
of each movement the control unit will regulate start-up of the operator,
gradually increasing the force from the minimum to the value set by the
“FORCE” trimmer during the rst 2 seconds of operation. Repeat the
procedure if you wish to restore the previous conguration.
Note: when the Soft Start function is enabled the control unit automatically
disables the Starting Torque function, while if Soft Start is disabled then
Starting Torque is automatically enabled.
3. DS 1 also in opening:
The control unit allows the operation of input DS1 to be modied. If you
want DS 1 to operate also during opening (momentary stopping of the
gate, as soon as the photocell is freed the control unit resumes the opening
movement), proceed as follows: ensure you have enabled Extended Menu
2 and then press the SEL key to select blinking LED L3 and press the SET
key: LED L3 becomes steady on and programming will be completed.
as follows if you wish to enable the function: make sure you have enabled
extended Menu 1, use the select key to select blinking LED L1 and then
press the SET key; at the same time LED L1 will become steady on and
programming will be completed.
Repeat the procedure if you wish to restore the previous conguration.
2. PED MOT. T. (Programming of pedestrian opening motor time of
max 4 minutes):
The control unit is factory set with Motor Time (Pedestrian opening) of 10
seconds without any deceleration.
If the pedestrian motor time must be changed, programming must be
carried out with the gate closed as follows: ensure you have enabled
Extended Menu 1, use the SELECT key to select blinking LED L2 and
then press the SET key momentarily. The Operator will start the Opening
cycle; when the gate reaches the desired initial deceleration position press
the SET key again: LED L2 will start blinking more slowly and the Operator
performs the deceleration; when the desired position is reached press the
SET key to terminate the Opening cycle. At this point LED L2 returns to the
normal blinking speed and the Operator restarts in the Closing movement;
repeat the operations described above for the Closing movement.
If you do not require the control unit to perform the deceleration, during
programming, when the opening and closing cycle has been completed
press the SET key twice consecutively rather than just once.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand
3. DECELERATION:
As indicated above, the control unit allows a deceleration stage to be
programmed during opening and closing, while with the Automatic
Programming function the deceleration stage is included automatically.
However, if no deceleration is required, this stage can be inhibited. In this
manner, when using Automatic Programming the Deceleration stage will
no longer be included, while if the Operator Times Programming function
is used the option of specifying a deceleration stage during opening and
closing will no longer be available. If, before excluding the deceleration
stage it had already been programmed using the Operator Times
Programming function, programming must be repeated from the beginning.
If the deceleration stage is to be excluded proceed as follows: make
sure you have enabled Extended Menu 1, use the SELECT key to select
blinking LED L3 and then press the SET key: LED L3 becomes steady on
and programming will be completed. Repeat the procedure if you wish to
restore the previous conguration.
4. REMOTE CODE PGM (Remote Programming of Radio remote
controls):
The control unit allows the transmission code to be programmed remotely
without acting directly on the control unit SELECT key.
Remote programming of a Radio remote control is performed as follows:
send, continuously for a time in excess of 10 seconds, the code of a
previously saved remote; at the same time the control unit switches
to programming mode as described above for the CODE LED in the
main menu. If a pedestrian code previously stored in the control unit is
transmitted continuously, the control unit switches to programming of a
new pedestrian code. The control unit is factory set with transmission code
remote programming disabled; proceed as follows if you wish to enable the
function: make sure you have enabled extended Menu 1, use the SELECT
key to select blinking LED L4 and then press the SET key; at the same time
LED L4 will become steady on and programming will be completed. Repeat
the procedure if you wish to restore the previous conguration.
5. RELEASE STROKE:
The control unit is factory set with the Release Stroke function disabled. To
enable the Release Stroke function at maximum power, proceed as follows:
make sure you have enabled Extended Menu 1, use the SELECT key to
select blinking LED L5 then press the SET key, LED L5 becomes steady on
and the programming procedure will be completed. If you wish to enable
the Release Stroke function at the power set with the “FORCE” trimmer,
repeat the procedure described above, press the SELECT key twice (LED
L5 will blink rapidly) rather than just once. Repeat the procedure if you wish
to restore the initial conguration.
This procedure makes it possible to facilitate release of the gate lock and
thus allow correct execution of the opening stroke. With this function, before
starting the opening stroke the control unit sends a closing command for 2
seconds with the thrust force associated with the selection made.
6. SLAM LOCK:
The control unit is factory set with the Slam Lock function disabled. This
function consists in adding, in the presence of a deceleration stage during

18 COMUNELLO ®Copyright 2014 - All right reserved
Repeat the procedure if you wish to restore the initial conguration.
4. HOLD-TO-RUN:
The control unit provides the opportunity to set the “Hold-to-run” function.
If you wish to enable the function, proceed as follows: ensure you have
enabled Extended Menu 2 and then use the SEL key to select blinking LED
L4 and press the SET key; at the same time LED L4 becomes steady on
and the operation will be completed. With this function enabled using either
the remotes or the Pushbuttons to operate the gate, the following operation
will be obtained: the command must be maintained constantly to move
the gate. When the command is released movement will stop immediately.
Repeat the procedure if you wish to restore the previous conguration.
5. FOLLOW ME
The control unit allows the “Follow me” function to be congured;
programmable only if a Pause Time has already been set, this function
reduces the Pause Time to 5 seconds after freeing the SAFE1 photocell,
meaning the gate re-closes 5 seconds after transit of the user. To activate
this function proceed as follows: ensure you have enabled Extended
Menu 2 and then press the SELECT key to select blinking LED L5 and
then press the SET key: LED L5 becomes steady on and programming will
be completed. Repeat the procedure if you wish to restore the previous
conguration.
6. FLASHING LIGHT OPERATION
The control unit is factory set with Flashing Light during Pause Time
disabled. If you wish to enable this function, proceed as follows: make
sure you have enabled Extended Menu 2, press the SELECT key to select
blinking LED L6 and then press the SET key: LED L6 becomes steady on
and programming will be completed. Repeat the procedure if you wish to
restore the previous conguration.
7. ALWAYS CLOSE
The control unit provides the facility to set “Always Close” operation: this
function, which is programmable only if a Pause Time has already been
programmed, is activated after a power loss; if the gate open condition
is conrmed a closing movement is started automatically, preceded by
5 seconds of preashing. If you wish to enable the function, proceed as
follows: ensure you have enabled Extended Menu 2 and then use the SEL
key to select blinking LED L7 and press the SET key; at the same time LED
L7 becomes steady on and the operation will be completed. Repeat the
procedure if you wish to restore the previous conguration.
EXTENDED MENU 3
The control unit is factory set to allow direct selection exclusively of the main
menu functions.
If you wish to enable the functions described in Extended Menu 3, proceed
as follows: select blinking LED no. 8 and press SET 3 times. The LED will
start blinking alternately 1 1 1 0 1 1 1 0 1 1 1 0. This means there is a
period of 30 seconds to select the functions in Extended Menu 3 using the
SEL and SET keys and then, after a further 30 seconds, the control unit will
revert to the main menu.
EXTENDED MENU 3
level
L1 1LED 1
L2 2LED 1 +LED 2
L3 3LED 1 +LED 2 +LED 3
L4 4LED 1 + LED 2 +LED 3 +LED 4
L5 5LED 1 + LED 2 +LED 3 +LED 4 +LED 5
L6 6LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6
L7 7LED 1 + LED 2 +LED 3 +LED 4 +LED 5 + LED 6 + LED 7
LEV MENU 3 FLASHIES
DECELERATION FORCE ADJUSTMENT:
Operator force during the deceleration stage can be programmed on the
control unit. You can select one of 7 different power levels as follows; ensure
you have enabled Extended Menu 3; each combination of lit LEDs denes
a level as shown in the above table; in practice, starting from the bottom
LED (LED 1) and proceeding upward, each additional LED corresponds to
a higher power level. Use the SEL key to scroll through the different power
levels; for each selected power level the top LED will blink (for example,
selecting level 4, LED 1 + LED 2 + LED 3 will be steady on, while LED 4 will
blink); press SET to conrm. Factory setting: level 3 selected.
RESET:
If it becomes necessary to reset the control unit to restore the factory
settings, press the SELECT and SET keys together; this will cause all the
RED indicator LEDs to light simultaneously followed immediately by the
control unit switching off
DIAGNOSTICS:
Photocell Test:
The control unit is prearranged for connection of safety devices in
compliance with standard EN 12453 point 5.1.1.6. At each operating
cycle a functional test of the connected photocell is performed. In the case
of an open circuit and/or malfunctioning of the photocell, the control unit
does not enable movement of the gate and visually signals the test failed
condition by causing all the indicator LEDs to blink simultaneously. As soon
as correct operation of the photocell is restored the control unit is ready for
normal use. This operating mode guarantees failure mode monitoring in
compliance with EN 954-1 Category 2
Commands input test:
In correspondence with each low voltage command input the control unit
is equipped with an indicator LED so that the status of the input can be
checked at a glance. Operating logic: LED on input closed, LED off input
open.
WARRANTY
Fratelli Comunello SpA provides a warranty for 24 months for the correct
functioning of the actuators from the date of manufacture, provided that the
performance specications indicated in the product instruction manuals are
respected. Free of charge repair and replacement of components that are
found to be faulty according to the indisputable judgment of the company’s
technical staff shall be guaranteed at the sole discretion of Fratelli Comunello
Spa, and so excluding any claim for damages made by others. Warranty
material shall be returned to Fratelli Comunello S.p.a. headquarters carriage
paid and will then be shipped to the customer carriage unpaid. The material
found to be faulty and returned to Fratelli Comunello S.p.a. shall remain
property of the Seller. Any cost resulting from any work needed to repair
the defect or to replace the material shall be charged to the Buyer. No
compensation shall be allowed for the period of device inactivity. Work under
warranty does not prolong the warranty period. The defect of the product
shall be reported by the Buyer within 8 (eight) days from its discovery or
from the date of delivery of the goods, under penalty of invalidation of the
warranty. Such claim shall be notied in writing.
Warranty does not cover:
Any product defect or damage that may have been incurred during
transport; any defect or damage arising from any fault and/or from neglect,
inadequacy and misuse of the electrical wiring in the Buyer’s property; any
defect or damage caused by any repairs carried out by non authorised
personnel or by incorrect use/installation (with reference to this, system
maintenance is recommended every 6 months) or if not original spare parts
are used; any defect caused by chemicals or atmospheric conditions. The
warranty does not cover any cost neither for consumable materials nor for
alleged defects or convenient surveys.
Product Features Fratelli Comunello SpA products are subjected to
continue changes and improvements; their technical features and image
may therefore change without previous notice.
Competent court
Since the contract of sale is conrmed by an Order Conrmation drawn up
in Rosà, any such dispute shall be settled by the laws of Italy and by the
court of Vicenza (VI).

FRATELLI COMUNELLO S.P.A.
AUTOMATION GATE DIVISION
Via Cassola, 64 - C.P. 79
36027 Rosà, Vicenza, Italy
Tel. +39 0424 585111 Fax +39 0424 533417
Table of contents
Other Comunello Control Unit manuals

Comunello
Comunello CU 24V 2M ONE User manual

Comunello
Comunello CU 230V HP User manual

Comunello
Comunello CU-230V-1M User manual

Comunello
Comunello CU-230V-1M User manual

Comunello
Comunello QUAD 24V HP User manual

Comunello
Comunello CU-24V-2M User manual

Comunello
Comunello CU 230V HP User manual

Comunello
Comunello CU 230V HP User manual

Comunello
Comunello QUAD - 24V - 2M User manual

Comunello
Comunello CU-110V-1M User manual