nstallation
As is the case with most power amplifiers, the MF2275 amplifier
dissipates a significant amount of heat. Provision must be made for
adequate ventilation. Mount the unit on a flat, hard surface, taking
care that the ventilation holes in the bottom are unobstructed.
Maintain at least four inches of clearance above the unit, and at
least three inches on the sides. The cabinet or shelf should be
open at both front and back. For more restricted installations,
cooling fans are essential.
All MF2275 amplifiers sold in the United States are configured for
operation on a 60Hz ac power line producing between 108 and 126
volts. Export versions of the MF2275 will have the correct
operating voltage and frequency clearly marked on the back panel
of the unit, near the ac power cord. In all cases, the actual line
voltage should be within + 5/- 10% of the nominal rated voltage.
Electromagnetic Interference (EMI)
Considerable care has been taken in the design of the MF2275 to
minimize its susceptibility to radio frequency interference and other
forms of EMI. Choice of materials, physical layout, grounding
practice, and power supply design have all been specified with a
view to reducing the impact of electromagnetic fields on the
performance of this unit. At the same time, however, our primary
goal is the accurate reproduction of recorded music in the normal
home environment, and we have elected not to compromise this
objective by the application of heavy-handed RFI filters, or by using
grounding practices that reduce RFI at the expense of degraded
audio performance. We find that the approach we have taken has
worked extremely well, resulting in only rare instances of EMI
problems which could be treated locally as needed, rather than
compromising the performance of our product in the 99.9% of
installations where EMI is not a problem.
Care in installation can often avoid EMI induced problems. The
following practices should generally be observed in any
application, and will be especially important where EMI may be a
problem.
Interconnect cables should be kept as short as possible (3 meters
or less), and shielded cable should be used (cable which has two