manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Contro l4
  6. •
  7. Gateway
  8. •
  9. Contro l4 Vibrant eDIDIO S10 User manual

Contro l4 Vibrant eDIDIO S10 User manual

Specifications
The specifications are described below.
Model Number CRE-EDIDIO-10-1D, CRE-EDIDIO-10-1X,
CRE-EDIDIO-10 -2X, CRE-EDIDIO-10 -1D-1X
Input voltage 24V DC
Battery backup 3V DC, CR2032
DC input polarity reversal Immune
Overcurrent protection Ye s
Transient protection Yes
OLED screen 128 x 64, organic LED
Dimensions (WxHxD) 2.8 x 3.5 x 4.1" (72 x 88 x 105 mm) excluding terminals
2.8 x 4.3 x 4.1" (72 x 108 x 105 mm) with terminals
Weight (approximate) 0.4 lb (170 g)
Meets or exceeds relevant
standards
AS/NZS 61347.2.1; EN 55015 + A1; EN61547+A1.
CE and C Tick, IEC/AU CISPR15
Warnings and considerations
IMPORTANT! Read all installation instructions before beginning; if not qualified,
do not attempt installation. Contact a qualified electrician.
IMPORTANT! To reduce the risk of fire, electric shock, or injury to persons, pay
close attention to this manual and stay within its guidelines when using this
product. Save these instructions for future use.
IMPORTANT! Do not cover this product with paper surface coverings, fabrics,
streamers, or other similar combustible materials.
IMPORTANT! This device is rated for indoor use in dry locations.
IMPORTANT! Do not secure this product or its cord with staples, nails, or like
means that may damage the outer jacket or cord insulation.
IMPORTANT! Do not install in airtight tanks or enclosures of any kinds.
WARNING! These products may represent a possible shock or fire hazard if
improperly installed or attached in any way. Products should be installed in
accordance with these instructions, current electrical codes, and/or the current
National Electric Code (NEC).
WARNING! To reduce the risk of fire, electric shock or injury to persons, make
sure that the electrical power to the system is disconnected at the source prior to
installation or any servicing.
WARNING! Turning o connected lights via DALI or DMX commands does not
disconnect power to the fixtures.
WARNING! This device must be protected by a circuit breaker (20A max).
ATTENTION! Cet appareil doit être protégé par un disjoncteur (20A max.)
IMPORTANT! Snap One is NOT liable for any damage incurred with the misuse
of this product.
IMPORTANT! Snap One does not guarantee the performance of any device in
your environment. Customer assumes all risks, including any damage to snap
one products, associated with (i) the type, load rating and quaility of the device,
or (ii) any use or installation not in accordance with the documentation furnished
by snap one, either with the snap one product or at www.snapone.com.
Installing the gateway
Fasten the gateway onto a DIN rail.
Wiring the gateway
Refer to the wiring diagrams below to wire the gateway. The first
digram shows a DMX-only configuration. The second diagram shows
DMX, DALI, and contact input configuration.
Connecting Power
The gateway requires a 24V DC (>100mA) source (HDR60-24
recommended). Connect power to the gateway input screw down
terminals marked DC IN + and DC IN -. The cable must be less than 98
feet (30 meters) from the DC power supply to the gateway.
For DALI to work, an external DALI PSU must be present on each line
(CRE-UBI-V2-PWR recommended).
Creative Lighting made for Control4 Vibrant
DALI/DMX Gateway Installation Guide
DALI line connection
The DALI line wires are connected in the screw terminals at the top of
the enclosure as shown below. You must not have two DALI line power
supplies on the same DALI line. DALI Standard mandates no more
than 2V DC voltage drop.
DMX512-A line connection
The DMX512-A line wires are connected in the screw terminals at the
top of the enclosure as shown above.
WARNING! Do not confuse the DALI and DMX512-A lines.
Connecting a DALI bus PSU to a DMX512-A line will cause
irreversible damage.
Contact input connection
The inputs of the gateway allow for short, long, and latching presses
by connecting the input pin source to a ground pin source. This means
that any potential-free contact, such as a switch mech or relay device,
that can connect two wires together may be used as an input device
for the gateway.
The inputs 1 to 8 will show about 3V DC (in reference to the GND pin)
when floating, allowing for easy testing via multimeter. I/Os 9 to 12 will
initially show a higher dc voltage and decay down to 3V DC over time.
A display option is also available using the keypad/menu to show the
state of each input.
Supported models
• CRE-EDIDIO-10-1D - Digital Lighting Gateway, DALI 1 bus
• CRE-EDIDIO-10-1X - Digital Lighting Gateway, DMX 1 universe
• CRE-EDIDIO-10-2D - Digital Lighting Gateway, DALI 2 buses
• CRE-EDIDIO-10-2X - Digital Lighting Gateway, DMX 2 universes
• CRE-EDIDIO-10-1D-1X - Digital Lighting Gateway, 1 Dali bus, 1 DMX
universe
Accessories
• CRE-SPLTR-V2-LTNG: DMX Splitter Repeater with added protection
from lightning
• CRE-UBI-V2-PWR: DALI Power 21V DC (250 mA)
• HDR-60-24: 24V DC, 60W power supply
• CRE-ADDICT: ADDICT V3 for DALI, DMX commissioning, with RDM
support and WiFi
Introduction
The eDIDIO S10 gateway is a modular, network-enabled, DIN rail
mounted, DALI and DMX lighting controller. It supports up to two lines
of control via DALI, DMX, or both. This model is specially configured
to work with Control4.
Features
Modular control: Modular hardware allows for any combination of
up to two (total) DALI and or DMX512-A outputs while still maintaining
proper DMX512-A signal conditioning and DALI separation.
Custom Control4 protocol: The eDIDIO supports custom Control4
protocol that includes support for SDDP, TLS 1.2, and additional
features.
Easy installation: DIN Mounted with plug-and-play connectors: a
black 2-way for DC in, a 12-way for I/Os, 2 x 3-ways for data lines,
and a 4-way for logic ground and IR. If the controller is moved or
removed, the connectors can remain conveniently behind, leaving the
existing wiring connected to the connectors.
Multi-line control: Any interface or trigger in the system can call a
command over multiple connected lines.
Easy-to-use configuration: An easy-to-use interface through
Composer provides quick configuration and commissioning.
Easy wiring and system verification: The gateway contains a function
which turns on all channels, making it easy to verify wiring and
perform troubleshooting. See Troubleshooting, below, for details.
D+ D-
DALI/DMX1 DALI/DMX2 LG INFRARED 24VDC IN
D+ D- IR 3.3 – +
DC IN
DATA
1 2 3
INPUTS IN/OUTS
1 2 3 4 5 6 7 8 9 10 11 12
CONTROL
Network Enabled
FREAK
eDIDIO
Made in Australia
24VDC in <100mA
DMX
Decoder
1 2
3 4
N L
24VDC
Power Supply
DC OUT
AC IN
Main
Circuit Breaker
–
+
+
N L
N
DMX decoder connections (model CRE-EDIDIO-10-1D-1X shown)
D+ D-
DALI/DMX1 DALI/DMX2 LG INFRARED 24VDC IN
D+ D- IR 3.3 – +
DC IN
DATA
1 2 3
INPUTS IN/OUTS
1 2 3 4 5 6 7 8 9 10 11 12
CONTROL
Network Enabled
FREAK
eDIDIO
Made in Australia
24VDC in <100mA
DMX
Decoder
1 2
3 4
N L
24VDC
Power Supply
DC OUT
AC IN
Main
Circuit Breaker
–
+
+
N L
N
DA
DA
DA POWER
DA DA DA
DA DA DA DA DA DA
– +
DC INTEST
TEST
WARNING
OVERVOLTAGE
DALI
DALI
DC
CONTROL
FREAK
UBi
DALI Out: Branch 4 of 4
DALI Out: Branch 1 of 4
DALI Out: Branch 2 of 4
DALI Out: Branch 3 of 4
DALI to UBi Power
L N
DIN Relay
Dry Contact
DMX decoder, DALI, and contact input connections (model CRE-EDIDIO-10-1D-1X shown)
Configuration with Composer Pro
We recommend that you take the Control4 Vibrant Linear Lighting
Micro-Certification at http://ctrl4.co/certification-vibrant. It provides
detailed explanations and video procedures for setting up DMX-
controlled lighting.
Perform the following procedure to configure your DMX gateway
and decoder in Composer Pro:
1. Open Composer Pro and connect to the project.
2. Add gateway drivers.
a. In the Items pane > Discovered tab > Manufacturer, find
“CONTROLFREAK” and double-click to add driver. Repeat this
for each gateway in the project.
b. The gateway will reboot and may install updates. While
updating, the driver will not respond. Do not remove power
during this process.
c. You may track progress on the gateway’s Properties tab.
Give each gateway in the project a descriptive name.
3. Add DMX drivers.
a. For each zone of LED tape light, add one instance of the DMX
light driver.
b. In the Items pane > Search tab, type “DMX Light”, press Enter.
Find and double-click “DMX Light Driver” to add.
c. Name the zone after the area it’s illuminating (unless the
customer has a preference).
4. Connect DMX Light drivers to the Lights
a. Click Connections > Control/AV tab. Select a gateway.
b. DMX devices have automatically connected to the first
gateway added to the project.
i If there is more than one gateway in the project, reconnect
the DMX devices to the correct gateways.
ii Select a gateway. From the Control Outputs pane, drag
the output to the DMX device it will control. Do this for all
gateways in the project.
Display
The gateway has a 128 x 96-pixel display that shows the time, status,
and other useful information.
Home Screen
The home screen displays the time and date, as well as battery,
temperature, and connection status icons. The battery icon appears
when the PCB battery is below its recommended voltage, the
temperature icon displays when over 50 degrees, and the connection
status icon displays when a valid Ethernet connection is accepted.
An information line is available at the bottom of the display which
provides status updates on schedules, burn-in, or current profile. The
default is schedule status and is settable using the keypad menu.
Pressing any button opens the menu. With no user interaction after 10
seconds, the display automatically returns to the home screen.
Main Menu and 1, 2, 3 Buttons
The main menu shows options for Installation, Testing, and Settings.
Button 1moves the cursor up, button 3moves the cursor down, and
button 2confirms selection.
Copyright ©2022, Snap One, LLC. All rights reserved. Control4 and SnapAV and their respective logos are registered trademarks or trademarks of Wirepath Home Systems, LLC, dba “Control4” and/or dba “SnapAV” in
the United States and/or other countries. 4Store, 4Sight, Control4 My Home, Snap AV, Araknis Networks, BakPak, Binary, Dragonfly, Episode, Luma, Mockupancy, Nearus, NEEO, Optiview, OvrC, Pakedge, Sense, Strong,
Strong Evolve, Strong Versabox, SunBriteDS, SunBriteTV, Triad, Truvision, Visualint, WattBox, Wirepath, and Wirepath ONE are also registered trademarks or trademarks of Wirepath Home Systems, LLC. Other names and
brands may be claimed as the property of their respective owners. All specifications subject to change without notice.
200-EDIDIO-10-XX-XX SERIES-A 20221215 MK
Installation
The installation allows for random addressing of DALI fittings.
Testing
The testing screen allows for DALI and DMX512-A Min/Max
commands, displaying of inputs, and counting devices. The Min/Max
testing command is one of the best troubleshooting processes that you
can use to test the DMX and DALI buses before commissioning and
programming the system.
Settings
The settings screen lets you choose between various options, such as
status information display and muting/unmuting sensors.
Troubleshooting
• Device not found by discovery: Check the connections and make
sure the network symbol is present on the gateway OLED.
• Using the keypad menu, check in Settings > Device Status
to see if an IP has been set. If it is 0.0.0.0, check the router’s
network settings to make sure it supports DHCP.
• Device fails to select appropriate version: Reset power to the
controller and make sure network is not aected by other devices.
• Startup system check: On startup, various systems are checked.
They will display on the screen for 5 seconds after the standard
boot sequence.
• To easily verify your wiring and system setup, press any button on
the gateway. From the main menu, go down to Testing > Min/
Max DMX or DALI (depending on the device). Press 2to confirm.
The lights will cycle full on and o. If your lights do not turn on,
you may have a wiring problem.
Warranty and legal information
We want to make our Third-Party Partner program as easy as
possible. That’s why we process all claims directly, without any third
party telephone tag. Contact Customer Service at
866.424.4489
.
Find other legal resources, such as regulatory notices and patent
information, at
snapone.com/legal
.

This manual suits for next models

5

Other Contro l4 Gateway manuals

Contro l4 C4-DIN-BEG-V2 User manual

Contro l4

Contro l4 C4-DIN-BEG-V2 User manual

Contro l4 C4-DIN-BEG User manual

Contro l4

Contro l4 C4-DIN-BEG User manual

Popular Gateway manuals by other brands

Cloudleaf GW-1A2I2 user guide

Cloudleaf

Cloudleaf GW-1A2I2 user guide

RLE Technologies FDS-Wi user guide

RLE Technologies

RLE Technologies FDS-Wi user guide

ABB 83342-500 operating instructions

ABB

ABB 83342-500 operating instructions

RTA 460PSBM-NNA4 Product user guide

RTA

RTA 460PSBM-NNA4 Product user guide

Etisalat DGA4231ETI Quick Installation Guide & Safety Instructions and Regulatory Information

Etisalat

Etisalat DGA4231ETI Quick Installation Guide & Safety Instructions and Regulatory Information

Honeywell INNCOM PC-503 manual

Honeywell

Honeywell INNCOM PC-503 manual

Multitech MultiVOIP GSM SIP-to-Cellular Gateways... user guide

Multitech

Multitech MultiVOIP GSM SIP-to-Cellular Gateways... user guide

Huawei B890-75 quick start

Huawei

Huawei B890-75 quick start

Weinzierl KNX RF/TP Coupler 670 Installation and operating manual

Weinzierl

Weinzierl KNX RF/TP Coupler 670 Installation and operating manual

Weidmüller IE-GW-MB-2TX-1RS232/485 Hardware installation guide

Weidmüller

Weidmüller IE-GW-MB-2TX-1RS232/485 Hardware installation guide

ViewSonic WPG-360 user guide

ViewSonic

ViewSonic WPG-360 user guide

RTA 460ETCA-NNA1 Product user guide

RTA

RTA 460ETCA-NNA1 Product user guide

Extron electronics ShareLink 200 user manual

Extron electronics

Extron electronics ShareLink 200 user manual

Duemmegi Domino DFDALI manual

Duemmegi

Duemmegi Domino DFDALI manual

NetComm SmartVoice V404 Specifications

NetComm

NetComm SmartVoice V404 Specifications

SURFboard SBG6700-AC user guide

SURFboard

SURFboard SBG6700-AC user guide

Portech MV-372 user manual

Portech

Portech MV-372 user manual

RTA 460ETCMS-N700 Product user guide

RTA

RTA 460ETCMS-N700 Product user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.