SPECIFICATIONS
Display: 0.6”-high LCD
Temperature— Range: –58 to 1999°F
(–50 to 1230°C)
Resolution: selectable 0.1°/1°
Accuracy: ±(0. 5% + 1°C)
±(0. 5% + 2°C)
Sampling time: 0.8 to 1.0 sec
Data output: RS 232 PC serial interface
Case: ABS plastic
Si e/Weight: ⅛ x 2⅞ x 1
1
/
3
inches/9¾ ounces
QUICK REFERENCE
On Turns unit on.
Off Turns unit off.
Data Hold “Freezes” the display at the current temperature reading.
Memory Record Activates the Record mode to enable the minimum and maximum
temperature readings to be recorded and stored for recall.
Memory Recall Displays the stored minimum and maximum temperature readings
while in Record mode.
°F/°C Permits switching between Fahrenheit and Celsius temperature
scales.
Function Permits viewing both temperature channel readings and the
differential temperature reading.
1.0°/0.1° Switches between two temperature resolutions—1.0° and 0.1°.
TEMPERATURE MEASUREMENT
Single Probe measurement
1. Press ON button to power unit.
2. Determine temperature scale (°F or °C) by pressing the °F/°C button.
3. Determine temperature resolution (0.1° or 1.0°) by pressing the 1°/0.1° button.
4. Insert temperature probe into T1 socket. It may be necessary to press the
FUNCTION button until “T1” is displayed, indicating the unit is sampling from the
probe in the T1 socket.
Note: The cable and connectors are keyed, don NOT insert cable incorrectly and force
it.
Dual probe and differential measurement
1. Press ON button to power unit.
2. Determine temperature scale (°F or °C) by pressing the °F/°C button.
3. Determine temperature resolution (0.1° or 1.0°) by pressing the 1°/0.1° button.
4. Insert temperature probe into T1 socket and another temperature probe into T2
socket.
Note: The cables and connectors are keyed, do NOT insert the cables incorrectly and
force them.
5. Press the FUNCTION button to alternate between viewing temperature readings
from probe T1, probe T2, and the differential temperature. The FUNCTION
button alternates between the following settings:
When “T1” is displayed, the upper display indicates temperature reading from T1
probe. The T2 probe temperature reading appears on lower display.
When “T2” is displayed, the upper display indicates temperature reading from T2
probe. The T1 probe temperature reading appears on lower display.
When “T1 - T2” is displayed, the upper display indicates differential temperature
of T1 and T2 probes. The T1 probe temperature reading appears on lower
display.
DATA HOLD FUNCTION
1. To “freeze” the display at the current temperature reading(s), press the DATA
HOLD button (“D.H” will appear along the top of the display).
Note: While in the Hold mode, pressing the °C/°F, FUNCTION, 1°/0.1°, MEMORY
RECORD, or MEMORY RECALL button will have no affect and will not change the
“frozen” display.
2. Push the DATA HOLD button a second time to return to normal temperature
sampling (“D.H will no longer appear on the display).
MEMORY RECORD
Press MEMORY RECORD button to activate the Record mode. Once the Record
mode, the unit will begin recording minimum and maximum temperature readings
achieved for the probe indicated on the main display (“T1” or “T2”) (“REC” will appear
along the bottom of the display).
Warning: The Automatic Shutoff feature is disabled while in Record mode so that
long-term monitoring may be performed.
MEMORY RECALL
1. While in the Record mode, press the MEMORY RECALL button to recall the
minimum and maximum temperature recordings for the probe appearing on the
upper display (“T1” or “T2”).
2. The maximum temperature recording appears on the first press of the MEMORY
RECALL button (“Max”) and the minimum temperature recording appears on the
second press (“Min”). A third press of the MEMORY RECALL button returns the
display to the current temperature reading.
3. Exit the Record mode by pressing the MEMORY RECORD button.
Warning: The minimum and maximum temperature recordings are automatically
cleared once the Record mode has been exited.
AUTOMATIC SHUTOFF
After 10 minutes, if no button has been pressed, the unit will automatically shut off to
preserve battery life. The automatic shutoff can be overridden by entering the Record
mode (see “Memory Record” section).
RS-232 PC INTERFACE
The unit features an RS-232 output via 3-pole 3.5 mm plug. The output is a 16-digit
data stream that may be utilized for user-specific applications.
Available as an accessory is an RS-232 lead with a 3-pole 3.5 mm jack on one end
(plugs into unit) and a 9-pin female D-Subminiature connector on the other end (plugs
into computer COM port). It is required to link the instrument with a PC.
(Pin 2 = Center Pin, Pin 5 = Ground/Shield)
The 16-digit data stream will appear in the following format: D15, D14, D13, D12, D11,
D10, D9, D8, D , D6, D5, D4, D3, D2, D1, D0.
Each digit indicates a particular status as shown below:
D0 = End word
D1 to D4 = Upper display reading (D1 = LSD, D4 =MSD)
D5 to D8 = Lower display reading (D5 = LSD, D8 =MSD)
D9 = Decimal point (DP) for upper display (0 = No DP, 1 = 1 DP,2 = 2 DP, 3 = 3 DP)
D11 and D12 = Annunciator for upper display (00 = No symbol, 01 = °C, 02 = °F, 03 =
%, 04 = %RH, 05 = pH, 06 = %O
2
, 0 = mg/l, 08 = m/s, 09 = knots, 10 = km/h, 11 =
ft/min, 12 = mile/h, 13 = µS, 14 = mS, 15 = Lux, 16 = ft-cd, 1 = dB, 18 = mV)
D13 = Annunciator for lower display (0 = No symbol, 1 = °C, 2 = °F)
D14 = Polarity (±) for the display (0 = Upper and lower display are “+”; 1 = Upper “-”,
lower “+”; 2 = Upper “+”, lower “-”; 3 - Both upper and lower are “-”)
D15 = Start word
DISPLAY MESSAGES
An “LBT” message indicates that the battery is low and needs replacement (see
“Battery Replacement” section)
A “---” message indicates that the reading is outside the range of the unit.
TRACEABLE
®
DUAL-CHANNEL THERMOMETER WITH RS-232 OUTPUT INSTRUCTIONS
Traceable
®
is a registered trademark of Control Company ©2008 Control Company. 92-413 -00 Rev. 1 052008
ALL OPERATIONAL DIFFICULTIES
If this temperature meter does not function properly for any reason, please replace the
battery with a new, high-quality battery (see “Battery Replacement” section). Low
battery power can occasionally cause any number of “apparent” operational difficulties.
Replacing the battery with a new fresh battery will solve most difficulties.
BATTERY REPLACEMENT
An erratic display, faint display, no display, or “LBT” appearing on the display are all
indicators that the battery needs replacement. Remove the battery cover. Remove the
exhausted battery and replace it with a new 9-volt alkaline battery. Replace the battery
cover.
ACCESSORIES
Cat. No. 4136 Data Acquisition System — Complete DAS–3™ Data Acquisition
System captures, displays, and stores readings on any IBM-compatible PC.
Information can be imported into databases. Diskette (3.5 inches) and 5-foot serial
cable with D9F plug.
Cat. No. 4325 Data Logger — Complete DAS–4™ System captures and stores up to
8000 bytes (over 1000 readings). Readings may be taken at intervals from 1 second to
99 hours. Stored readings may be downloaded to any PC and viewed. Can be read
as-is or imported to spreadsheets, databases, and statistical programs. Supplied
complete with 36-inch serial cable with D9F computer plug, 3.5-inch diskette
(Windows
®
, DOS), and four AA alkaline batteries. Size is 5 x 3 x 1 inches. Weight is
ounces. For use with Traceable
®
meters featuring RS-232 output.
Cat. No. 4008 Surface Probe — Stainless-steel with handle, triple purpose.
Temperature range is – 3 to 60°C. Dimensions: 5-inch probe length; 0.5-inch tip
diameter; 8½-inch overall length. Supplied with 36-inch cable.
Cat. No. 4014 Stainless Steel Probe — Stainless-steel with handle, triple purpose
(liquids, air/gas, and semi-solids), Type K (NiCr/NiAl) probe. Temperature range is –50
to 00°C. Dimensions: 0.13-inch diameter; 6¼-inch stem length; 9¾-inch overall
length. Supplied with 40-inch cable.
Cat. No. 4028 Beaded Probe — Fast-Response, Type K thermocouple, beaded
probe. Teflon cable can withstand temperatures of -40 to 250°C continuous or 300°C
short-term use. Dimensions: 0.06-inch diameter probe with cable length of 4 feet for
use with all Type K thermometers in liquids, air/gas, and semi solids.
Cat. No. 4138 Easy-Use Adaptor — 115 VAC
Cat. No. 8039 Low-Temperature Probe — Stainless-steel with handle; triple purpose
(liquids, air/gas, and semi-solids), Type K (NiCar/NiAl) probe. Temperature range is -
240 to 220°C. Dimensions: diameter 0.1 inch; stem length 12 inches; overall length
1 inches. Supplied with 8-foot expandable cable.
Cat. No. 8613 High-Temperature Probe — Ten-foot-long 0.19-inch diameter braided
metal wire cable with smooth tip measures – 3 to 982°C continuous or 1093°C short-
term use. For use with all Type K thermometers in liquids, air/gas, and semi-solids.
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
4455 Rex Road
Friendswood, Texas 77546 USA
Ph. 281-482-1714 Fax 281-482-9448
E- ail sales@control3.co
www.control3.co
Control Co pany is ISO 9001 Quality-
Certified by DNV and ISO 17025 accredited
as a Calibration Laboratory by A2LA.

Other Control Company Thermometer manuals

Control Company TRACEABLE User manual

Control Company

Control Company TRACEABLE User manual

Control Company TRACEABLE User manual

Control Company

Control Company TRACEABLE User manual

Control Company Traceable 4381 User manual

Control Company

Control Company Traceable 4381 User manual

Control Company TRACEABLE MEMORY-LOC User manual

Control Company

Control Company TRACEABLE MEMORY-LOC User manual

Control Company TRACEABLE 3650 User manual

Control Company

Control Company TRACEABLE 3650 User manual

Control Company Traceable 4000 User manual

Control Company

Control Company Traceable 4000 User manual

Control Company 4227 User manual

Control Company

Control Company 4227 User manual

Control Company TRACEABLE FLIP-STICK 4272 User manual

Control Company

Control Company TRACEABLE FLIP-STICK 4272 User manual

Control Company TRACEABLE User manual

Control Company

Control Company TRACEABLE User manual

Control Company 4181 User manual

Control Company

Control Company 4181 User manual

Control Company TRACEABLE 4484 User manual

Control Company

Control Company TRACEABLE 4484 User manual

Control Company TRACEABLE 4110 User manual

Control Company

Control Company TRACEABLE 4110 User manual

Control Company TRACEABLE ROBO 4149 User manual

Control Company

Control Company TRACEABLE ROBO 4149 User manual

Popular Thermometer manuals by other brands

Yummly YTE000W5K user manual

Yummly

Yummly YTE000W5K user manual

ThermoPro TP-20 instruction manual

ThermoPro

ThermoPro TP-20 instruction manual

Presys T-30NIR-H Technical manual

Presys

Presys T-30NIR-H Technical manual

Gima 25609 quick start guide

Gima

Gima 25609 quick start guide

Oregon Scientific RMR382 user manual

Oregon Scientific

Oregon Scientific RMR382 user manual

Clas Ohlson OT5228B manual

Clas Ohlson

Clas Ohlson OT5228B manual

Koch 14000 manual

Koch

Koch 14000 manual

Vicks OviTrack instruction manual

Vicks

Vicks OviTrack instruction manual

Smartro ST55 user manual

Smartro

Smartro ST55 user manual

Reed Instruments FS-200 instruction manual

Reed Instruments

Reed Instruments FS-200 instruction manual

La Crosse Technology 308-1409BTV3 Faqs

La Crosse Technology

La Crosse Technology 308-1409BTV3 Faqs

geo-FENNEL FIRT 1600 Data user manual

geo-FENNEL

geo-FENNEL FIRT 1600 Data user manual

Beurer FT 58 Instructions for use

Beurer

Beurer FT 58 Instructions for use

Gima 25564 user manual

Gima

Gima 25564 user manual

Mobi Technologies tempTalk operating instructions

Mobi Technologies

Mobi Technologies tempTalk operating instructions

Oakton 35629-00 instruction manual

Oakton

Oakton 35629-00 instruction manual

York Survey Supply 32058 operating instructions

York Survey Supply

York Survey Supply 32058 operating instructions

bbluv Termo instruction manual

bbluv

bbluv Termo instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.