manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Control Company
  6. •
  7. Thermometer
  8. •
  9. Control Company TRACEABLE User manual

Control Company TRACEABLE User manual

Other manuals for TRACEABLE

5

Other Control Company Thermometer manuals

Control Company TRACEABLE User manual

Control Company

Control Company TRACEABLE User manual

Control Company TRACEABLE 4137 User manual

Control Company

Control Company TRACEABLE 4137 User manual

Control Company Traceable 4381 User manual

Control Company

Control Company Traceable 4381 User manual

Control Company 4227 User manual

Control Company

Control Company 4227 User manual

Control Company TRACEABLE 4484 User manual

Control Company

Control Company TRACEABLE 4484 User manual

Control Company TRACEABLE 3650 User manual

Control Company

Control Company TRACEABLE 3650 User manual

Control Company TRACEABLE FLIP-STICK 4272 User manual

Control Company

Control Company TRACEABLE FLIP-STICK 4272 User manual

Control Company TRACEABLE User manual

Control Company

Control Company TRACEABLE User manual

Control Company 4181 User manual

Control Company

Control Company 4181 User manual

Control Company TRACEABLE MEMORY-LOC User manual

Control Company

Control Company TRACEABLE MEMORY-LOC User manual

Control Company Traceable 4000 User manual

Control Company

Control Company Traceable 4000 User manual

Control Company TRACEABLE 4110 User manual

Control Company

Control Company TRACEABLE 4110 User manual

Control Company TRACEABLE ROBO 4149 User manual

Control Company

Control Company TRACEABLE ROBO 4149 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SPECIFICATIONS
Range: –58 to 302°F
Resolution: 0.1°
Accuracy: ±2°F between –4 to 248°F
otherwise ±4°F
OPERATION
1. Press the ON/OFF button to turn the unit
on. The unit will only read °F Fahrenheit.
2. Insert the probe into the material to be
measured and read the display.
3. Press the ON/OFF button to turn the unit
off. To conserve battery life, always turn
the unit off when not in use.
ALL OPERATIONAL DIFFICULTIES
If this thermometer does not function properly
for any reason, replace the battery with a
new high quality battery (see the “Battery
Replacement” section). Low battery power
can occasionally cause any number of “ap-
parent” operational difculties. Replacing the
battery with a new fresh battery will solve
most difculties.
MIN/MAX MEMORY
1. Press MAX/MIN to display maximum
recorded reading.
2. Press MAX/MIN again to display the
minimum record reading.
3. Press MAX/MIN once more to return the
display to current reading.
4. Switch thermometer off then on to reset
the memory reading to current reading.
5. Reset the memory once before taking
new maximum or minimum reading.
BATTERY REPLACEMENT
Erratic readings, a faint display, or no display
are all indicators that the battery must be
replaced. To replace the battery, loosen the
two screws at the rear of the case. Remove
the face of the thermometer taking care not
to disconnect the internal wiring. Replace
exhausted battery with a new 1.5-volt, silver
oxide, 389 size battery. Make certain positive
(+) side is visible. Replace the face of the unit
and tighten the screws. Do not over-tighten
the screws as this may damage the unit.
NOTE: When replacing the face of the unit, care-
fully ensure the back is properly in place and the
screws are tightened securely to maintain the unit’s
water-resistance.
©2016 Control Company. 92-4770-00 Rev. 1 061016
TRACEABLE
SHORT-STEM
THERMOMETER
INSTRUCTIONS
Control Company Cat. No. 4770
WARRANTY, SERVICE, OR RECALIBRATION
For warranty, service, or recalibration, contact:
CONTROL COMPANY
12554 Old Galveston Rd. Suite B230
Webster, Texas 77598 USA
Ph. 281 482-1714 • Fax 281 482-9448
E-mail [email protected]
www.traceable.com
Control Company is ISO 9001:2008 Quality-Certied
by DNV and ISO/IEC 17025:2005 accredited as a
Calibration Laboratory by A2LA.
®