manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Controlli
  6. •
  7. Control Unit
  8. •
  9. Controlli VSBT3 User manual

Controlli VSBT3 User manual

This manual suits for next models

12

Other Controlli Control Unit manuals

Controlli VSBT User manual

Controlli

Controlli VSBT User manual

Controlli MVECS R Series User manual

Controlli

Controlli MVECS R Series User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Terminal unit and
zone valve actuators
Rev. a 03/04 1 DBL157E
ISO 9000
CONTROLLI
MVT
CONTROLLI Division
16010 SANT’OLCESE Genova - Italy
Tel.: +39 01073061 Fax: +39 0107306870/871
E-mail: [email protected] Web: www.controlli.org
APPLICATION
MVT actuator is designed to provide, with V.T and V.BT valve
bodies, floating control of hot/cool water in two/four-pipe fan-
coil units, zone and solar plants, reheat coils and dehumidifi-
cation batteries.
ACCESSORIES
MVT44C1 Cable for MVT441 3-wire 1,5 m (CEI 20-22/II)
N4149
OPERATION
POSSIBLE COMBINATIONS AND
CONNECTIONS
MVTactuatorsaretobeusedwithCONTROLLIVST,VMT,VTT,
VSBT,VMBTvalves.
The MVT4. series can be connected to any 3-position control-
ler, with characteristics corresponding to details included in
the paragraph “TECHNICAL CHARACTERISTICS”.
The MVT5. series is standard proportional as indicated on table
1.
Due to the presence of the magnetic clutch, the actuator could
be continuously powered up without damages but, for life in-
crease and energy saving, it is highly reccomended to use a
controller equipped with a cut-off function (suggested timing
120% of stroke time).
MANUFACTURING CHARACTERISTICS
The actuator consists of a base and a housing made of syntetic
materials which contain motor, gear box, magnetic coupling,
valve driving screw spindle.
A ring nut M30x1.5 is placed on the lower part; it allows an easy
coupling to the valve without special tools.
The actuator is equipped with a cable for 3-wire electrical con-
nection. It requires no maintenance.
TECHNICAL CHARACTERISTICS
Power supply 24 V ~ +10%
Consumption 0,5VA (MVT4.)
1VA (MVT5.)
Frequence 50/60 Hz
Stroke timing 100 s for V.T valves having
5,5 mm stroke (at 50 Hz)
Speed 18 s/mm at 50 Hz - 15 s/mm
at 60 Hz
Force 200 N (UNI 9497)
Stroke 6,5 mm
Temperature:
- working -5T55 °C
- storage -25T65 °C
Protection class III (IEC 950)
Connecting cable 3-wire 1,5 m (CEI 20-22/II)
Protection degree IP43 CEI EN 60529
Weight 0,2 Kg.
The product conforms to EMC 89/336 directive with
reference to the below-mentioned standards:
for emission EN 50081-1 for immunity EN 50082-1
INSTALLATION AND MOUNTING
The actuator can be mounted in the positions indicated below.
Before assembling the actuator to the valve, remove the pro-
tection cap from valve and make sure that the actuator screw
spindle corresponds to the upper notch on the base plate (fac-
tory supplied position). Otherwise, it is advisable to consider
that, in order to mount the actuator on the valve correctly, the
force of the valve internal spring will have to be overcome.Then
it should be fixed by tightening the M30X1,5 ring nut on the
thread located on the valve body (Fig. 1).
Mounting positions allowed
MVT actuator is electric bidirectional.
The valve stem movement is produced by rotation of a screw
spindle connected, through a gear train, to a synchronous bidi-
rectional motor.
An internal magnetic hysteresis coupling limits the torque on
the valve stem, avoiding the usage of microswitches and pro-
tecting the actuator from overload.
PART
NUMBER CONTROL SIGNAL POWER SUPPLY
MVT44 3 position
MVT441 3 position
without cable
MVT56 proportional
0…10/6…10/1…5/2…10
4…7/6…9/8…11V-
MVT57 proportional
0…10V-
MVT56A proportional
4÷20 mA
24 V~
TABLE1
N4038
Perform the electrical connections in compliance with existing
rules (Fig. 2)
Through the slits located by the ring nut, it is possible to ob-
serve the valve stem movement.
With 24 V~ voltage between white (common) and brown the
actuator lowers the valve stem, between white (common) and
green the actuator lifts the valve stem.
Rev. a 03/04 2DBL157E
ISO 9000
CONTROLLI Automatic control systems for:
air conditioning/heating/industrial thermal process.
V.T. AND VB.T VALVES-ACTUATOR ASSEMBLY
N4039 Fig. 1
MVT56
MVT57 MVT56/56A/57
Brown =24 V~ 50/60 Hz
White =Common
Green =V Control signal
A Never perform nor change electrical connections when
power supply in on.
ELECTRICAL DIAGRAM
N3032
MVT56A
N4150
RANGESELECTION
RANGE AND ACTION SELECTION
The actuator is supplied with 0..10 V- signal and direct action.
In case a different setting is required:
•Remove the rubber plug (see the figure below)
• Switch on ‘ON’ position the DIP 2..8 corresponding to the
required range.
• Direct action: Position DIP N.1 on OFF
Screw spindle lowers if signal increases (V.T and VB.T
valves, direct way opened).
•Reverse action: Position DIP N.1 on ON
Screw spindle raises if signal decreases (V.T and VB.T
valves, direct way closed).
•Replace the rubber plug in the previous position.
RANGE DIP NR..
0..10 V 2
6..9 V 3
1..5 V 4
2..10 V 5
4..7 V 6
6..10 V 7
8..11 V 8
MVT57 actuator has 0..10 V- fixed working signal, direct action.
MVT56A actuator has 4..20 mA fixed working signal, direct ac-
tion.
MVT44
Supply the controller-actuator system, after having mounted
the actuator on the valve body and once the electrical
connections are performed and the action ranges selected.
When powered, the actuator reaches one stroke end and
remainsinthispositionforabout2min. Afterwards, the actuator
will reach the position set by the controller signal
(MVT56,57,56A).
START UP
DIMENSIONS (mm.)
MVT - V.T. VALVES ASSEMBLY OVERALL
DIMENSIONS
For MVT-valve assembly overall dimensions, make reference
to DBL025 data sheet (for V.T valves) and DBL102 (for VB.T
valves).
N4020
The performances stated on this sheet can be modified without any prior notice due to design improvement.
Fig. 2
MANUAL CONTROL
It is possible to start all MVT
models with manual control by
means of a socket head key (3
mm).
It is necessary to power off
the actuator before starting
the manual control.
N3135