manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Cooper Lighting
  6. •
  7. Work Light
  8. •
  9. Cooper Lighting Corelite User manual

Cooper Lighting Corelite User manual

This manual suits for next models

1

Other Cooper Lighting Work Light manuals

Cooper Lighting PQS45 User manual

Cooper Lighting

Cooper Lighting PQS45 User manual

Cooper Lighting Sure-Lites CCX Series User manual

Cooper Lighting

Cooper Lighting Sure-Lites CCX Series User manual

Cooper Lighting MCL5 User manual

Cooper Lighting

Cooper Lighting MCL5 User manual

Cooper Lighting PQS45 User manual

Cooper Lighting

Cooper Lighting PQS45 User manual

Cooper Lighting LED110 User manual

Cooper Lighting

Cooper Lighting LED110 User manual

Cooper Lighting SURE-LITES Photoluminescent Exit Signs User manual

Cooper Lighting

Cooper Lighting SURE-LITES Photoluminescent Exit Signs User manual

Cooper Lighting PHL300 User manual

Cooper Lighting

Cooper Lighting PHL300 User manual

Cooper Lighting LED120 User manual

Cooper Lighting

Cooper Lighting LED120 User manual

Cooper Lighting IRIS E4LWW User manual

Cooper Lighting

Cooper Lighting IRIS E4LWW User manual

Cooper Lighting McGraw-Edison IMI-6950 User manual

Cooper Lighting

Cooper Lighting McGraw-Edison IMI-6950 User manual

Cooper Lighting McGraw-Edison EPL/DLS Envoy User manual

Cooper Lighting

Cooper Lighting McGraw-Edison EPL/DLS Envoy User manual

Popular Work Light manuals by other brands

Conrad 77 70 78 operating instructions

Conrad

Conrad 77 70 78 operating instructions

EBS Seeberg 1 Operation manual

EBS

EBS Seeberg 1 Operation manual

Pelican 9460 user manual

Pelican

Pelican 9460 user manual

Anslut 425-080 User instructions

Anslut

Anslut 425-080 User instructions

Govee H6071 user manual

Govee

Govee H6071 user manual

LumX INSPEC LED instruction manual

LumX

LumX INSPEC LED instruction manual

LED2WORK TECLED User instructions

LED2WORK

LED2WORK TECLED User instructions

ANSMANN POWERLIGHT 5.1 operating instructions

ANSMANN

ANSMANN POWERLIGHT 5.1 operating instructions

RTRMAX RTX1868 instruction manual

RTRMAX

RTRMAX RTX1868 instruction manual

FeinTech LAL00220 quick start guide

FeinTech

FeinTech LAL00220 quick start guide

Bunker Hill Security 64735 user manual

Bunker Hill Security

Bunker Hill Security 64735 user manual

Goobay 30450 user manual

Goobay

Goobay 30450 user manual

REV Ritter SPOT Assembly and operating instructions

REV Ritter

REV Ritter SPOT Assembly and operating instructions

Ignition Stagepix Line 100 IP user manual

Ignition

Ignition Stagepix Line 100 IP user manual

SCANGRIP DUO CONNECT manual

SCANGRIP

SCANGRIP DUO CONNECT manual

Bosch GLI 18 V operating instructions

Bosch

Bosch GLI 18 V operating instructions

Bayco SL-1514 instruction manual

Bayco

Bayco SL-1514 instruction manual

EUFAB SMD LED 8+1 operating instructions

EUFAB

EUFAB SMD LED 8+1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

WARNINGS
1). WARNING! Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
2). WARNING! - Risk of Fire/Electric Shock. If not qualified, consult an electrician.
3). WARNING! – Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when
drilling for installation of reflector kit hardware. Check for enclosed wiring and components.
4). WARNING! – Avoid contact with LED modules.
NOTES
1). NOTE! - This product must be installed in accordance with the applicable installation code by a certified
electrician, familiar with the construction and operation of the product and hazards involved.
2). NOTE! - Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit
installation. Do not leave any other open holes in an enclosure of wiring or electrical components.
3). NOTE! - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
4). NOTE! - Disconnect all power before proceeding.
5). NOTE! - “Doghouse” component on end of fixture is intended for T8 lamping only. A maximum of (8) fixtures can be
mounted in a continuous row with each “Doghouse” facing the opposite direction starting from the center of the run.
Class R6 LED or Fluorescent
Installation Instructions - page 1 of 2
Corelite 18001 East Colfax Ave. Aurora, CO 80011 Ph. (303) 393-1522 Fax (303) 393-1477
ADE111698 rev 021213
1. Unpack fixture from box.
3. To install fixture into grid, raise it through an adjacent cell and then into the cell
where it is to be installed.
5. After securing fixture tabs to grid frame, use holes in tabs to tie fixture back to
structure at all four corners or per local code.
2. If installing an LED fixture, leave the lens installed during installation. If install-
ing a fluorescent module, the lens should be left installed until just prior to
installing lamps.
4. Bend all four side tabs out and secure fixture to grid.
6. Make appropriate wire connections adhereing to local electrical code.
If installing an LED fixture,
this is the final step. If
installing a fluorescent
fixture, go to page 2.
WARNINGS
1). WARNING! Risk of Electric Shock. Disconnect power at fuse or circuit breaker before installing or servicing.
2). WARNING! - Risk of Fire/Electric Shock. If not qualified, consult an electrician.
3). WARNING! – Risk of fire or electric shock. Luminaires wiring, ballasts, or other electrical parts may be damaged when
drilling for installation of reflector kit hardware. Check for enclosed wiring and components.
4). WARNING! – Avoid contact with LED modules.
NOTES
1). NOTE! - This product must be installed in accordance with the applicable installation code by a certified
electrician, familiar with the construction and operation of the product and hazards involved.
2). NOTE! - Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit
installation. Do not leave any other open holes in an enclosure of wiring or electrical components.
3). NOTE! - To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or any sharp objects.
4). NOTE! - Disconnect all power before proceeding.
5). NOTE! - “Doghouse” component on end of fixture is intended for T8 lamping only. A maximum of (8) fixtures can be
mounted in a continuous row with each “Doghouse” facing the opposite direction starting from the center of the run.
Class R6 Fluorescent
Installation Instructions - page 2 of 2
Corelite 18001 East Colfax Ave. Aurora, CO 80011 Ph. (303) 393-1522 Fax (303) 393-1477
ADE111698 rev 021213
1. Remove lens.
3. Replace the lens.
2. Insert T5 or T8 fluorescent lamp into the fixture. For T8 lamping, install one
end of the lamp into the socket inside the “doghouse” compartment first. Then
install the other end and make sure the lamp is secure.