1. Introduction
The i-on160EX is the control unit for a
hybrid wired/wirefree alarm system
intended for commercial or large domestic
use.
The control unit comprises a steel case
containing the control unit pcb (printed
circuit board), power supply and space for
backup batteries.
The control unit pcb provides terminals for
a single bus. The bus allows you to connect
up to 45 peripheral devices using standard
four wire alarm cable. The peripheral
devices can be any mixture of keypads,
zone expanders (for wireless or wired
detectors) or output expanders.
The control unit pcb also provides a range
of connectors for outputs, communicators,
and up to 10 FSL (Fully Supervised Loop) or
five CC (Closed Circuit) zones.
The i-on160EX uses i-kp01 keypads with
software revision 2.0 and above. The
keypads allow end users to set and unset
the system, and the installer to configure
the control unit. The keypads also contain
integral proximity tag readers, allowing end
users to control the system without having
to remember access codes.
A range of wireless peripherals is available
for operation with the wireless expanders.
These include a door contact/universal
transmitter, a passive infra red detector,
smoke detector, external siren, 4 button
remote control, and remote radio keypad.
This control unit is designed and approved
to be used as part of a Security Grade 3
system. The control unit is also approved to
operate as part of a Security Grade 2
system. If you install any radio devices this
will limit approval to Security Grade 2 in
the partition in which they are used.
Communications
The i-on160EX provides sockets for an add-
on communication module. The available
modules are:
i-sd02
(ATS2)
A speech dialler and public
switched telephone network
(PSTN) module that allows the
control unit to send recorded
speech messages and report
alarm information using
standard protocols such as
Fast Format, SIA and Contact
ID. This module also allows
remote maintenance.
i-dig02
(ATS2)
A switched telephone network
(PSTN) module that allows the
control unit to report alarm
information using standard
protocols such as Fast Format,
SIA and Contact ID. This
module also allows remote
maintenance.
i-gsm02
(ATS2)
A GSM module that allows
alarm reporting, speech
messaging and SMS text
messaging over the mobile
phone network.
08750EUR-
00
(ATS5)
An Ethernet module that allows
alarm reporting and remote
maintenance over the internet.
08844EUR-
00
(ATS5)
A GPRS module that allows
internet protocol access over
the mobile phone network.
The control unit also provides outputs that
can be used to fit a “plug by”
communicator.
To comply with EN50131 at Security Grade
2 you must fit an ATS2 communicator (for
example the i-sd02).
To be approved at Security Grade 3 use the
plug on modules 08750EUR-00 or
0844EUR-00. Alternatively use the plug-by
communicator outputs to connect the
control unit to an ATS4 communicator.
Level Setting or Partitioned System
The i-on160EX offers two basic ways of
behaving as an alarm system:
Part Setting. In a Part Setting system the
i-on160EX can set in one of four ways:
either Full set or three varieties of Part Set.
In Full set the control unit pays attention to
all detectors. In each of the three Part Sets
the control unit ignores detectors that do
not have the appropriate Part Set attribute.
Partitioned System. In a Partitioned
system the i-on160EX provides the
equivalent of 20, smaller, independent
alarm systems. Each system is a “Partition”
of the i-on160EX. You can allocate any zone
to each Partition. Each zone can also belong
to more than one Partition. Each Partition
can have a Full Set level and one Part Set
level. During installation the installer can
allocate keypads, sounders or outputs to
any of the partitions.