Transport
CTC CombiAir should be transported and stored vertically
in a dry place.
NOTE
Ensure that the heat pump cannot fall over
during transport.
Check that CTC CombiAir has not been damaged during
transport.
Lift from the street to the set up location
If the surface allows, the easiest method is to use a pallet
truck to move the heat pump to the installation area.
If the heat pump needs to be transported across soft
ground, such as a lawn, we recommend using a crane
truck that can lift it to the installation location. When
the heat pump is lifted with a crane, the packaging must
be intact.
If a crane truck cannot be used, the heat pump can be
transported on an extended sack truck. The heat pump
must be taken hold of from its heaviest side and two
people are required to lift it.
Lift from the pallet to final positioning
Before lifting remove the packaging and the securing
strap to the pallet.
Place lifting straps around each foot. It is recommended
that two people perform the lift from the pallet to the
base.
Scrapping
When scrapping, remove the heat pump in reverse order.
In this case, lift by the base plate rather than the pallet!
Assembly
■Place the heat pump in a suitable location outdoors
to prevent any risk of the refrigerant flowing in
through ventilation openings, doors or similar open-
ings in the event of a leak. It must also not constitute
a hazard to people or property in any other way.
■If the heat pump is placed in a location where any re-
frigerant leak could accumulate, for example below
ground level (in a dip or low-lying recess), the installa-
tion must satisfy the same requirements that apply for
gas detection and the ventilation of engineering
rooms. Requirements regarding sources of ignition
must be applied where appropriate.
■Place CTC CombiAir outdoors on a solid level base that
can take the weight, preferably a concrete foundation.
If concrete slabs are used they must rest on asphalt or
shingle.
■The lower edge of the evaporator must not be lower
than the level of the average local snow depth, or at
least 300 mm above ground level. The base should be
at least 70 mm tall.
■CTC CombiAir should not be positioned next to noise
sensitive walls, for example, next to a bedroom.
■Also ensure that the placement does not inconveni-
ence the neighbours.
■CTC CombiAir must not be placed so that recirculation
of the outdoor air is possible. Recirculation entails re-
duced power and impaired efficiency.
■The evaporator must be sheltered from direct wind / ,
which negatively affects the defrosting function. Place
CTC CombiAir protected from wind / against the
evaporator.
■Large amounts of condensation, as well as melt water
from defrosting, may be produced. Condensation must
be led off to a drain or similar (see section “Condensa-
tion water").
■Care must be exercised so that the heat pump is not
scratched during installation.
Do not place CTC CombiAir directly on the lawn or other
non solid surface.