manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Media Converter
  8. •
  9. CTC Union FRM220-10/100 User manual

CTC Union FRM220-10/100 User manual

www.ctcu.comwww.ctcu.com
www.ctcu.com
10/100BASE-T/TX to 100BASE-FX
Fiber Media Converters - FRM220-10/100
User Guide
Panel
■Figure #2. Rear Panel of Stand-alone FRM220-10/100
AC Adapter 10/100-AA 10/100-DD 10/100-AD 10/100-DC 10/100-AC
■Figure #1. Front Panel of FRM220-10/100
[email protected][email protected]
[email protected]
CTC Union Technologies Co.,Ltd.
www.ctcu.com[email protected]
Description
The FRM Series gives you the option to choose from the most popular ber cabling
connectors. The FRM220-10/100 provides you with ST, SC or FC connectors for your ber optic
cables and RJ-45 port for 10/100Base-TX twisted pair cable connection. The factory default
settings of Ethernet auto-negotiation may be modied by adjustment of external DIP
switches to force Full/Half 10/100 or LFP function settings. The FRM220-10/100 gives you the
freedom to extend your 10/100Mbps cabling distance by allowing connectivity up to 120
kilometers over ber. Six LED indicators signal the power status of the converter, UTP port
speed, Link/Act, duplex status and FX port ink/Act
and FEF (Far End Fault).
Features
■10/100Base-TX to 100Base-FX Converter
■Auto-Negotiation or forced mode
■Auto MDI/MDIX
■Forward 1600 bytes (Max.) packets
■Support ow control (Pause)
■Supports Link Fault Pass through (LFP)
Specifications
Standards
IEEE802.3 10BASE-T, IEEE802.3u 100BASE-TX, l00BASE-FX
Supports Full/Half Duplex Ethernet mode N-Way Auto Negotlation
10/100BASE-TX RJ-45 Connectors
One RJ-45 connector is provided for connection to MDI-X (To PC) or MDI (To HUB) equipment.
Auto MDI-X allows all UTP connections to be made using only a common straight-through
UTP cable.
100BASE-TX UTP Cable
Cable type: 100Base-Tx; Category 5 or better
Maximum cable distance: 100 meters (328 feet)
Fiber Optic Connectors
Two connectors are provided for ber optic cable connection.
One is labeled "Tx" for transmission of optical data, the other is
labeled "Rx" for reception of optical data.
Environment
Operating -- -10°C – 60°C, Storage -- -20°C – 70°C,
Humidity -- 10 – 95%, (non-condensing)
MDI-X type MDI typeRJ-45 Pin
1
2
3
6
Rx+
Rx-
Tx+
Tx-
Tx+
Rx+
Tx -
Rx -
Power
Adapter: 12VDC 1A, Built-in AC Power 100~240V ±10% , Built-in DC Power 18~75VDC
Dimensions: (W x D x H) mm
10/100-DC12 : 88 × 160 × 24
10/100-AC/DC : 135 × 201 × 35
10/100-AD/AA/DD : 135 × 201 × 35
DC Jack
www.ctcu.com[email protected]www.ctcu.com[email protected]
www.ctcu.com[email protected]www.ctcu.com[email protected]
LED Indicators
LED Function State Status
Power indicator
Fiber link & activity
Far End Fault
Mode display
Mode display
Ethernet link & activity
On
O
On
O
Blinking
On
O
On
O
On
O
On
O
Blinking
Converter has power.
Converter has no power.
The ber link is ok.
No link or the link is faulty.
Receiving data on the ber.
Far end is experiencing link fault.
No fault.
Ethernet operates in 100Mbps
Ethernet operates in 10Mbps
Or no devices attached.
Full duplex mode ( 200mbps )
Half duplex mode ( 100mbps )
The UTP link is ok.
No link or the link is faulty.
Receiving data on Ethernet.
PWR
FX link/Act
FEF
100
Full
TX link/Act
100 PWR
FULL FEF
Link/Act Link/Act
TX FX
Dip Switch Setting
SW1
SW2
SW3
SW4
DIP
UTP Mode
UTP Speed
UTP Duplex
Link Fault Pass-through
Function
Auto mode.
Manual mode.
100Mbps.
10Mbps.
Full Duplex.
Half duplex.
LFP o.
LFP on.
Status
O
On
O
On
O
On
O
On
State
Connect the Ethernet cable to the FRM220-10/100I Series. The converter will sense
whether to operate in Full or Half mode and will be indicated on the LED. Follow the
connection examples below. Install the ber converter with the DC power adapter
provided (+12VDC, 1A) and connect the adapter to an AC outlet.
Installation
The following example illustrates the connection scheme when connecting from a
100BASE-TX port of one HUB to a 100BASE-FX port of another HUB through the ber
converter.
The following example illustrates the connection scheme when connecting from a
100BASE-TX port of one HUB to a 100BASE-TX Network Interface Card (NIC) in a computer
through the ber converter.
Connections
100BASE-FX Fiber
Connection
100BASE-TX UTP
straight connection
Fiber Cable
Full Duplex
Use RJ-45 jack
to HUB connection
Full Duplex
100BASE-TX UTP
straight connection
100BASE-TX UTP
straight connection Use RJ-45 jack to PC connection
Fiber Cable
Full Duplex
Use RJ-45 jack
to HUB connection
Figure: Explanation of LFP
Fiber
local remote
UTP
UTP
Link o
Converter BConverter A Switch or PCSwitch or PC
(1) TP port link failed (3) Fiber port gets remote link fault information
(5) Remote TP link is o
(4) TP link fail(2) Fiber port sends non-idle pattern
Link-Fault-Pass through (LFP) Application Note
When ‘link fault pass through’ function is enabled, link status on TX port will inform the FX
port of the same device and vice versa. From the link fault pass through explanation in the
gure below, if link fail occurrson TX port (1), the local FX port sends non-idle pattern to notify
the remote FX port (2). The remote FX port then forces its TX port to link failed after receiving
the non-idle pattern (4). This mechanism will alert the link fault status of local TX port to the
remote converter's TX port, and the link status of the remote TX port will become down. Link
status LED will also be o for both. Link Fault Pass through is enabled by setting DIP switch 4 (ON).
LPR
Full
100
Auto
ON
Half
10
Manual
WARNING
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
CE NOTICE
Marking by the symbol CE indicates compliance of this equipment to the EMC directive of the European Community. Such
marking is indicative that this equipment meets or exceeds the following technical standards:
EN 55022:1994/A1:1995/A2:1997 Class A and EN61000-3-2:1995, EN61000-3-3:1995 and EN50082-1:1997
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
ina commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and
used in accordance with the instruction manual may cause harmful interference in which case the user will be required to
correct the interference at his own expense. NOTICE: (1) The changes or modications not expressively approved by the party
responsible for compliance could void the user's authority to operate the equipment. (2) Shielded interface cables and AC power
cord, if any, must be used in order to comply with the emission limits.
CISPR PUB.22 Class A COMPLIANCE:
This device complies with EMC directive of the European Community and meets or exceeds the following technical standard. EN
55022 -Limits and Methods of Measurement of Radio Interference Characteristics of Information Technology Equipment. This
device complies with CISPR Class A.

This manual suits for next models

1

Other CTC Union Media Converter manuals

CTC Union DVS-8501E User manual

CTC Union

CTC Union DVS-8501E User manual

CTC Union IMC-100-PH12 User manual

CTC Union

CTC Union IMC-100-PH12 User manual

CTC Union FRM220-100AS-1 User manual

CTC Union

CTC Union FRM220-100AS-1 User manual

CTC Union FRM220-100M User manual

CTC Union

CTC Union FRM220-100M User manual

CTC Union FRM220-FXO-4 User manual

CTC Union

CTC Union FRM220-FXO-4 User manual

CTC Union OFC-1000PSE-AC User manual

CTC Union

CTC Union OFC-1000PSE-AC User manual

CTC Union FMC-1001S User manual

CTC Union

CTC Union FMC-1001S User manual

CTC Union FMC-10/100I series User manual

CTC Union

CTC Union FMC-10/100I series User manual

CTC Union IFC-100PD User manual

CTC Union

CTC Union IFC-100PD User manual

CTC Union FTH4-1000MS User manual

CTC Union

CTC Union FTH4-1000MS User manual

CTC Union FRM220-10/100iS-2 User manual

CTC Union

CTC Union FRM220-10/100iS-2 User manual

CTC Union FMC-1001S User manual

CTC Union

CTC Union FMC-1001S User manual

CTC Union FRM220-CCF40 User manual

CTC Union

CTC Union FRM220-CCF40 User manual

CTC Union IMC-100C User manual

CTC Union

CTC Union IMC-100C User manual

CTC Union FIB1-10/100 series User manual

CTC Union

CTC Union FIB1-10/100 series User manual

CTC Union FMC-10/100LF User manual

CTC Union

CTC Union FMC-10/100LF User manual

CTC Union FRM220A Manual

CTC Union

CTC Union FRM220A Manual

CTC Union IMC-100-E User manual

CTC Union

CTC Union IMC-100-E User manual

CTC Union IMC-1001C-E User manual

CTC Union

CTC Union IMC-1001C-E User manual

CTC Union PS-100 User manual

CTC Union

CTC Union PS-100 User manual

CTC Union FRM220 User manual

CTC Union

CTC Union FRM220 User manual

CTC Union FRM220-FXO User manual

CTC Union

CTC Union FRM220-FXO User manual

CTC Union DVS-8501D User manual

CTC Union

CTC Union DVS-8501D User manual

CTC Union FRM220-1000MS User manual

CTC Union

CTC Union FRM220-1000MS User manual

Popular Media Converter manuals by other brands

XVTEC XVC-HEVC Quick installation guide

XVTEC

XVTEC XVC-HEVC Quick installation guide

KBC ENC-H-W Series quick start guide

KBC

KBC ENC-H-W Series quick start guide

M-system WRPP instruction manual

M-system

M-system WRPP instruction manual

Danpex CFM3400 user manual

Danpex

Danpex CFM3400 user manual

Digitus DS-33150 user manual

Digitus

Digitus DS-33150 user manual

KSH International E-P432 Operation manual

KSH International

KSH International E-P432 Operation manual

Exsys EX-47200 installation guide

Exsys

Exsys EX-47200 installation guide

Weidmüller FreeCon Active PROFINET-POF-Media Converter manual

Weidmüller

Weidmüller FreeCon Active PROFINET-POF-Media Converter manual

Apogee PSX-100 Specifications

Apogee

Apogee PSX-100 Specifications

Baumer HOG 220 Installation and operating instructions

Baumer

Baumer HOG 220 Installation and operating instructions

Broadway Limited Paragon 4 Operator's manual

Broadway Limited

Broadway Limited Paragon 4 Operator's manual

IMC Networks McPC TP/BNC supplementary guide

IMC Networks

IMC Networks McPC TP/BNC supplementary guide

Idview Digital E-P132-X user manual

Idview Digital

Idview Digital E-P132-X user manual

Athena Power BP-SATA2221B user manual

Athena Power

Athena Power BP-SATA2221B user manual

Behringer ULTRAGAIN PRO-8 DIGITAL ADA8000 user manual

Behringer

Behringer ULTRAGAIN PRO-8 DIGITAL ADA8000 user manual

GRASS VALLEY 8960DEC - instruction manual

GRASS VALLEY

GRASS VALLEY 8960DEC - instruction manual

birddog MINI quick start guide

birddog

birddog MINI quick start guide

Lumagen Radiance XE-3D owner's manual

Lumagen

Lumagen Radiance XE-3D owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.