manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CTC Union
  6. •
  7. Media Converter
  8. •
  9. CTC Union IMC-100C User manual

CTC Union IMC-100C User manual

CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60, Zhouzi St., Neihu District, Taipei 114
Taiwan
T+886-2-26591021
F+886-2-26590237
E[email protected]
© 2015 CTC Union Technologies Co., Ltd.
All trademarks are the property of their respective owners.
Technical information in this document is subject to change without notice.
Introduction
IMC-100C(-E) are compact Fast Ethernet media converters that
support conversion between electrical 10/100Base-TX and optical
100Base-FX Ethernet. Housed in rugged DIN rail or wall
mountable enclosures, these converters are designed for harsh
environments, such as industrial networking and intelligent
transportation systems (ITS) and are also suitable for many
military and utility market applications where environmental
conditions exceed commercial product specifications. Standard
operating temperature range models (-10°C to 60°C) and wide
operating temperature range models (-40°C to 75°C) fulfill the
special needs of industrial automation applications.
Features
DC input power 12/24/48VDC or 24VAC
Compact size and fanless
IP30 rugged metal housing
Wide temperature range -40°C ~75°C (IMC-100C-E)
Support Link Fault Pass Through (LFPT)
Specifications
Ethernet Interface
Standards: IEEE802.3, 802.3u
Connector: RJ-45 (shielded)
Auto MDI/MDI-X
Speed: 10/100Base-TX
Support 802.3x Flow Control
Store & Forward Switch/Pass Through Converter mode (by DIP)
1024 MAC addresses in Switch mode
Packet Length: 2046 bytes (in Switch mode)
Jumble Frame: 9600 bytes (in Converter mode)
Link Fault Pass Through (LFP) (enable/disable by DIP)
Optical Interface
100Base-FX
Options for SC or ST connectors
Multimode (2KM) 50/125um, 62.5/125um
Single mode (30KM or 50KM) 9/125um
Wavelength: 1310nm (S/M or M/M)
Fiber Port Full Duplex or Half Duplex (by DIP)
Quick Installation Guide
IMC-100C
IMC-100C-E
Industrial 10/100Base-TX to 100Base-FX Fiber Converter
(Compact)
Specifications (cont.)
Power
DC Input Power: 12/24/48VDC (9.6~60VDC) or 24VAC
(18~36VAC)
Reverse Polarity Protection: Yes
Connector: Removable 2-pin terminal block
Consumption: 1.8W (DC 12V), 1.8W (DC 24V), 2.1W (DC 48V)
Mechanical
Water & Dust Proof: IP30 Protection
Dimensions: 70 mm (D) x 30 mm (W) x 103 mm (H)
Mounting: DIN-Rail mounting, Wall mounting (Optional)
Weight: 215 g
Environmental
Operating Temperature: -10°C~60°C (IMC-100C)
-40°C~75°C (IMC-100C-E)
Storage Temperature: -40°C~85°C
Humidity: 5%~95% (Non-condensing)
Certifications
EMC: CE
EMI (Electromagnetic Interference): FCC Part 15 Subpart B
Class A, CE EN55022 Class A
Railway Traffic: EN50121-4
Immunity for Heavy Industrial Environment: EN61000-6-2
Emission for Heavy Industrial Environment: EN61000-6-4
EMS (Electromagnetic Susceptibility) Protection Level:
EN61000-4-2 (ESD) Level 3, Criteria B
EN61000-4-3 (RS) Level 3, Criteria A
EN61000-4-4 (EFT) Level 3, Criteria A
EN61000-4-5 (Surge) Level 3, Criteria B
EN61000-4-6 (CS) Level 3, Criteria A
EN61000-4-8 (PFMF, Magnetic Field) Field Strength:
300A/m, Criteria A
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
MTBF (MIL-HDBK-217): 319,971 Hours
[email protected]
To download this QIG or a more complete user manual, please visit
http://www.ctcu.com/Industrial/
V1.0
- 2 -
- 1 -
www.ctcu.com
Panels
Figure 1. Front Panel
Figure 2. Top Panel
No.
Description
1
Power terminal block
2
Earth ground connector
3
LED indicators
4
LAN interface
5
Function DIP switch
6
Fiber interface
7
Earth ground sign
Table 1: Index Reference
Earth Ground Connection
An earth ground connector is provided on the top panel (See Figure 2)
with an earth ground sign next to it. Grounding the device can help to
release leakage of electricity to the earth safely so as to reduce injuries
from electromagnetic interference (EMI).
Prior to connecting to the power, it is important to connect the
ground wire to the earth. Follow steps below to install ground wire:
1. Remove the grounding screw.
2. Attach the grounding screw to the ring terminal of the grounding
cable. Make sure that the grounding cable is long enough to
reach the earth.
3. Use a screwdriver to fasten the grounding screw.
DC Power Connection
IMC-100C(-E) is powered up by an external power supply. On the top
panel, a removable 2-pin terminal block (See Figure 2) is provided for DC
power connection. To connect to the power supply, insert V+ and V-
wire into power contacts. Then, tighten the wire-clamp screws to
prevent power wires from loosening. If the power supply is connected
correctly, then the PWR LED on the front panel will light in green.
LED Indicators
LED
Color
Description
PWR
Green
Lit if power is connected and active.
Off
Power is not connected.
100
Green
The connected LAN speed is 100M.
Green Blinking
Blinking when there is Ethernet traffic.
Off
The LAN link is down or LAN speed is
10M.
10
Green
The connected LAN speed is 10M.
Green Blinking
Blinking when there is Ethernet traffic.
Off
The LAN link is down or LAN speed is
100M.
Fiber
LNK/ACT
Green
Fiber link is up and active.
Blinking
Blinking when there is Ethernet traffic.
Off
Fiber link is down.
DUP
Green
Fiber port works in full duplex.
Off
Fiber port works in half duplex.
Blinking
Blinking when there are collisions or
errors.
Fiber & LAN Connection
Both Fiber and LAN interface are located on the front panel
(See Figure 1). The Fiber interface of IMC-100C(-E) supports
100Base-FX and has fixed optical transceiver options for
connector types of ST or SC. The LAN connection supports
10/100Base-TX and uses a shielded RJ-45 connector which
supports Auto MDI/MDI-X.
Configuration settings are accomplished via a 4-pole DIP switch.
Please see below for the settings of the operation mode switch.
DIP Switch Function Descriptions
Pole No.
Status
Setting
Function Description
1
OFF *
Switch
Switching mode.
ON
Pass Thru
Pass through Converter mode.
2
OFF *
Disable
Disable link fault pass through.
ON
LFP
Enable link fault pass through.
3
OFF *
FX FDX
Fiber full duplex.
ON
FX HDX
Fiber half duplex.
4
Reserved for future use.
NOTE 1: By default, all DIP switches are set to OFF (marked with *).
NOTE 2: When LFP is enabled, the LAN port (Fiber port) link down will force Fiber
port (LAN port) link down.
Installation
The IMC-100C(-E) can be installed in DIN rail or mounted in wall
(optional). Hardware brackets for DIN rail installation are
provided with the device. However, wall-mounting brackets are
not provided. If you need wall-mounting installation kit, please
contact your sales representative.
When installing the DIN rail and wall-mounting bracket, be sure
to correctly align the orientation pin.
Figure 3. DIN Rail Figure 4. Wall Mounting
The IMC-100C(-E) with DIN Rail bracket has a steel spring in the
upper rail of the bracket. This spring is compressed for mounting
and un-mounting by applying downward force.
Figure 5. Mounting Figure 6. Un-mounting
Application
- 3 -
- 4 -
- 6 -
Figure 7. IMC-100C(-E) Application
- 5 -
1
2
7
1
3
4
2
5
6
www.ctcu.com

This manual suits for next models

1

Other CTC Union Media Converter manuals

CTC Union FRM220A Manual

CTC Union

CTC Union FRM220A Manual

CTC Union IMC-100 User manual

CTC Union

CTC Union IMC-100 User manual

CTC Union FRM220-10/100iS-2 User manual

CTC Union

CTC Union FRM220-10/100iS-2 User manual

CTC Union FRM220-FXO-4 User manual

CTC Union

CTC Union FRM220-FXO-4 User manual

CTC Union FIB1-1000ES User manual

CTC Union

CTC Union FIB1-1000ES User manual

CTC Union FRM220-1000MS User manual

CTC Union

CTC Union FRM220-1000MS User manual

CTC Union IMC-100-PH12 User manual

CTC Union

CTC Union IMC-100-PH12 User manual

CTC Union DVS-8504E User manual

CTC Union

CTC Union DVS-8504E User manual

CTC Union IMC-1000-PH12 User manual

CTC Union

CTC Union IMC-1000-PH12 User manual

CTC Union FMC-1000-PH User manual

CTC Union

CTC Union FMC-1000-PH User manual

CTC Union IMC-1001C-E User manual

CTC Union

CTC Union IMC-1001C-E User manual

CTC Union PS-100 User manual

CTC Union

CTC Union PS-100 User manual

CTC Union FMC-1001S User manual

CTC Union

CTC Union FMC-1001S User manual

CTC Union IMC-1000M-PH12 User manual

CTC Union

CTC Union IMC-1000M-PH12 User manual

CTC Union FRM220-100M User manual

CTC Union

CTC Union FRM220-100M User manual

CTC Union FRM220-100M User manual

CTC Union

CTC Union FRM220-100M User manual

CTC Union FRM220-FXO User manual

CTC Union

CTC Union FRM220-FXO User manual

CTC Union FRM220-100AS-1 User manual

CTC Union

CTC Union FRM220-100AS-1 User manual

CTC Union FMC-10/100I series User manual

CTC Union

CTC Union FMC-10/100I series User manual

CTC Union IMC-100-E User manual

CTC Union

CTC Union IMC-100-E User manual

CTC Union FIB1-10/100 series User manual

CTC Union

CTC Union FIB1-10/100 series User manual

CTC Union IMC-1000MS-PH12 User manual

CTC Union

CTC Union IMC-1000MS-PH12 User manual

CTC Union FRM220-2000MS User manual

CTC Union

CTC Union FRM220-2000MS User manual

CTC Union FMC-2000MS User manual

CTC Union

CTC Union FMC-2000MS User manual

Popular Media Converter manuals by other brands

DEVA Broadcast DB9000-TX instruction manual

DEVA Broadcast

DEVA Broadcast DB9000-TX instruction manual

Samlexpower IDC-100 owner's manual

Samlexpower

Samlexpower IDC-100 owner's manual

Lindy 43272 user manual

Lindy

Lindy 43272 user manual

Axis M7011 user manual

Axis

Axis M7011 user manual

Rotel RDA-986 Technical manual

Rotel

Rotel RDA-986 Technical manual

Roland UM-ONE owner's manual

Roland

Roland UM-ONE owner's manual

Huidu Technology HDP902 operation instruction

Huidu Technology

Huidu Technology HDP902 operation instruction

Z3 Technology Zeus manual

Z3 Technology

Z3 Technology Zeus manual

IMC Networks IE-MultiWay Operation manual

IMC Networks

IMC Networks IE-MultiWay Operation manual

Z3 Technology Z3-DME-10 User instructions

Z3 Technology

Z3 Technology Z3-DME-10 User instructions

MD mXion maXiCap user manual

MD

MD mXion maXiCap user manual

EMP-Centauri MS13/13+6ECU-4 instruction manual

EMP-Centauri

EMP-Centauri MS13/13+6ECU-4 instruction manual

OTS EC1212-X-MINI Series Quick installation guide

OTS

OTS EC1212-X-MINI Series Quick installation guide

THORLABS MX110G Series user guide

THORLABS

THORLABS MX110G Series user guide

Audioprobe SPARTAN CUE quick start guide

Audioprobe

Audioprobe SPARTAN CUE quick start guide

R.L.DRAKE DDC864 user guide

R.L.DRAKE

R.L.DRAKE DDC864 user guide

Kadtronix RWFC Quick Reference Installation Guide

Kadtronix

Kadtronix RWFC Quick Reference Installation Guide

Cypress CDL-165HUB Operation manual

Cypress

Cypress CDL-165HUB Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.