Cumberland EDGE 074-11770 Manual

EDGE Power Module 4 Outputs,
EDGE Power Module 2 Outputs
Models:
074–11770, 074–11771
Wiring Diagrams
891–00548
Version 3.0
Date: 07-15-18

All information, illustrations, photos, and specifications in this manual are based on the latest
information available at the time of publication. The right is reserved to make changes at any
time without notice.
2891–00548 EDGE Power Module Wiring Diagrams

1Wiring Diagrams
Topics Covered in this Chapter
▪ Wiring Diagrams
▪ Technical Specifications
Wiring Diagrams
Figure 1-1 Grounding, page 3
Figure 1-2 Variable Output (SSR) Wiring, page 4
Figure 1-3 Wiring Diagram With a SPST Disconnect Switch, page 4
Figure 1-4 Wiring Diagram With a DPST Disconnect Switch, page 5
Figure 1-1 Grounding
1
2
3
4
064-11343
064-11343
064-11343
064-11343
Proper grounding must be
followed for the heatsink
Load
L2/N
L1
Load
L2/N
L1
Load
L2/N
L1
Load
L2/N
L1
1
2
064-11343
064-11343
Load
L2/N
L1
891–00548 EDGE Power Module Wiring Diagrams 3

Chapter 1: Wiring Diagrams
Figure 1-2 Variable Output (SSR) Wiring
064-11343
Variable Output/SSR
Variable
Fan Electric
Heater Light/
Heat Lamp
Warning: Place the
connector with the
ferrite bead in the
EDGE Power
module enclosure
To variable module
L1
L2/N
L2/N
From electrical
distribution panel
100-240VAC
Output
L2/N wire return must
not share the same
wire as the load
Figure 1-3 Wiring Diagram With a SPST Disconnect Switch
Breaker circuit
SPST
disconnecting switch
EARTH
EARTH
N
L1
N
L1
To the
controller
4891–00548 EDGE Power Module Wiring Diagrams

Chapter 1: Wiring Diagrams
Figure 1-4 Wiring Diagram With a DPST Disconnect Switch
DPST
disconnecting switch
EARTH
EARTH
Breaker circuit
L2/N
L1
L2/N
L1
To the
controller
Technical Specifications
EDGE Power Module - Safety ratings
Resistive loads (heat lamps, heat
mats, incandescent light)
Requires a minimum load of 0.2A
16.66A A MAX
120 VAC, 2000 W, 16.66 A, 50/60 Hz
208 VAC, 2000 W, 9.61 A, 50/60 Hz
240 VAC, 2000 W, 8.33 A, 50/60 Hz
Motor/inductive loads 10.5 A MAX
Full Load amperage on the motor nameplate is not the maximum amp.
When varying, the amperage might be higher.
(Nb of Units = Max current rating divided by the max current of the fan)
Requires a minimum load of 0.2A
LED and CCFL loads 120/208/240Vac, 50/60 Hz, 750W, 920VA
Minimum load of 0.2A / 25W
Ballast loads 120Vac, 50/60 Hz, 1200W, 10A max
208 Vac, 50/60 Hz, 1040W, 5A max
240Vac, 50/60 Hz, 720W, 3A max
Requires a minimum load of 0.2A
Operating Temperature 0 to 40°C (32 to 104°F)
891–00548 EDGE Power Module Wiring Diagrams 5

Chapter 1: Wiring Diagrams
Storage Temperature -20 to 50°C (-4 to 122°F)
Environment Type Indoor use only
Pollution Degree 2
Installation Category 2
Altitude 2000 Meters Max. (5661 Ft. Max)
Operating Relative Humidity
(maximum)
0 to 10°C (32 to 50°F) Non condensing
10 to 30°C (50 to 86°F) 95 % (± 3 %) Non condensing
30 to 40°C (86 to 104°F) 95 % (± 3 %) Non condensing
IP rating (IEC 60529) 54
Nema Rating (Nema 250) 12
Flame Rating (UL94) 5VA-0
Flame Rating (IEC 60695 or IEC
60707)
FV-0
IK rating (degree of mechanical protec-
tion — impact, IEC 62262)
08
Main supply voltage fluctuations shall not exceed +/- 10% of the nominal supply voltage.
EDGE Power Module - Functional ratings
Enclosure dimensions Height 400 mm (15.75 inches)
Width 368 mm (14.5 inches)
Depth 154 mm (6 inches)
Clearance around the enclosure Top 305 mm (12 inches)
Bottom 305 mm (12 inches)
Left side 254 mm (10 inches)
Right side 178 mm (7 inches)
Weight 6 192 grams (13.65 lbs)
Inputs Specifications
SSR current sensor input Frequencies range: 40–70 Hz
Accuracy of ±0.6A for AC load <20A in a normal environment
6891–00548 EDGE Power Module Wiring Diagrams

NOTES
8891–00548 EDGE Power Module Wiring Diagrams

Chapter 1: Wiring Diagrams
GSI Group, LLC Limited Warranty
The GSI Group, LLC (“GSI”) warrants products which it manufactures to be free of defects in materials and workmanship
under normal usage and conditions for a period of 12 months after sale to the original end-user or if a foreign sale, 14
months from arrival at port of discharge, whichever is earlier. The end-user’s sole remedy (and GSI’s only obligation) is to
repair or replace, at GSI’s option and expense, products that in GSI’s judgment, contain a material defect in materials or
workmanship. Expenses incurred by or on behalf of the end-user without prior written authorization from the GSI Warranty
Group shall be the sole responsibility of the end-user.
Warranty Extensions: The Limited Warranty period is extended for the following products:
Product Warranty Period
AP Fans and Flooring
Performer Series Direct Drive Fan Motor 3 Years
All Fiberglass Housings Lifetime
All Fiberglass Propellers Lifetime
AP/Cumberland Flex-Flo/Pan Feeding System Motors 2 Years
Cumberland
Feeding/Watering
Systems
Feeder System Pan Assemblies 5 Years **
Feed Tubes (1-3/4" and 2.00") 10 Years *
Centerless Augers 10 Years *
Watering Nipples 10 Years *
Grain Systems Grain Bin Structural Design 5 Years
Grain Systems
Farm Fans
Zimmerman
Portable and Tower Dryers 2 Years
Portable and Tower Dryer Frames and
Internal Infrastructure † 5 Years
* Warranty prorated from list price:
0 to 3 years - no cost to end-user
3 to 5 years - end-user pays 25%
5 to 7 years - end-user pays 50%
7 to 10 years - end-user pays 75%
** Warranty prorated from list price:
0 to 3 years - no cost to end-user
3 to 5 years - end-user pays 50%
† Motors, burner components and
moving parts not included.
Portable dryer screens included.
Tower dryer screens not included.
GSI further warrants that the portable and tower dryer frame and basket, excluding all auger and auger drive components,
shall be free from defects in materials for a period of time beginning on the twelfth (12th) month from the date of purchase
and continuing until the sixtieth (60th) month from the date of purchase (extended warranty period). During the extended
warranty period, GSI will replace the frame or basket components that prove to be defective under normal conditions of
use without charge, excluding the labor, transportation, and/or shipping costs incurred in the performance of this extended
warranty.
Conditions and Limitations:
THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE LIMITED WARRANTY DESCRIPTION SET FORTH
ABOVE. SPECIFICALLY, GSI MAKES NO FURTHER WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING,
WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
USE IN CONNECTION WITH: (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (II) ANY ADVICE, INSTRUCTION,
RECOMMENDATION OR SUGGESTION PROVIDED BY AN AGENT, REPRESENTATIVE OR EMPLOYEE OF GSI
REGARDING OR RELATED TO THE CONFIGURATION, INSTALLATION, LAYOUT, SUITABILITY FOR A PARTICULAR
PURPOSE, OR DESIGN OF SUCH PRODUCTS.
GSI shall not be liable for any direct, indirect, incidental or consequential damages, including, without limitation, loss of
anticipated profits or benefits. The sole and exclusive remedy is set forth in the Limited Warranty, which shall not exceed
the amount paid for the product purchased. This warranty is not transferable and applies only to the original end-user. GSI
shall have no obligation or responsibility for any representations or warranties made by or on behalf of any dealer, agent
or distributor.
GSI assumes no responsibility for claims resulting from construction defects or unauthorized modifications to products
which it manufactured. Modifications to products not specifically delineated in the manual accompanying the equipment at
initial sale will void the Limited Warranty.
This Limited Warranty shall not extend to products or parts which have been damaged by negligent use, misuse, altera-
tion, accident or which have been improperly/inadequately maintained. This Limited Warranty extends solely to products
manufactured by GSI.
Prior to installation, the end-user has the responsibility to comply with federal, state and local codes which apply to the
location and installation of products manufactured or sold by GSI.
9101239_1_CR_rev8.xml (revised January 2014)
891–00548 EDGE Power Module Wiring Diagrams 9

This equipment shall be installed in accordance with
the current installation codes and applicable
regulations which should be carefully followed in all
cases. Authorities having jurisdiction should be
consulted before installations are made.
1004 E. Illinois St.
Assumption, IL 62510-0020
Phone: 1-217-226-4421
Fax: 1-217-226-4420
www.gsiag.com
AP and Cumberland are a part of GSI, a worldwide brand of AGCO Corporation.
Copyright © 2018 by GSI Group
Printed in Canada
CN #891–00548 895–00756 REV. 1
This manual suits for next models
1
Table of contents
Other Cumberland Control Unit manuals