4
SENZA VAPORIERA
Modello
LN
Alimentazione
elettrica
(V)
Potenza
(kW)
Consumo
medio
(kWh)
Assorb.
(A)
Cavo di
allacciamento
(Nxmm2)
Protezione
quadro
cliente
(nxA)
2T h.18 3Nx400V 11,8 7,1 17,0 5x2,5 4x20
3x280V 32,8 4xAWG7 3x40
2T h.25 3Nx400V 7 4,2 10,1 5x1,5 4x16
3x280V 19,4 4xAWG11 3x25
3T h.18 3Nx400V 16,2 9,7 23,4 5x4 4x32
3x280V 45,0 4xAWG7 3x50
3T h.25 3Nx400V 9,6 5,8 13,9 5x2,5 4x20
3x280V 26,6 4xAWG9 3x32
650 3Nx400V 18 10,8 26,0 5x4 4x32
3x280V 50,0 4xAWG7 3x63
CON VAPORIERA
Modello
LN
Alimentazione
elettrica
(V)
Potenza
(kW)
Consumo
medio
(kWh)
Assorb.
(A)
Cavo di
allacciamento
(Nxmm2)
Protezione
quadro
cliente
(nxA)
2T h.18 3Nx400V 13,3 8,0 19,2 5x2,5 4x20
3x280V 13,0 7,8 36,2 4xAWG7 3x40
2T h.25 3Nx400V 8,5 5,1 12,3 5x1,5 4x16
3x280V 8,2 4,9 22,8 4xAWG11 3x25
3T h.18 3Nx400V 17,7 10,6 25,5 5x4 4x32
3x280V 17,4 10,5 48,4 4xAWG7 3x50
3T h.25 3Nx400V 11,1 6,7 16,0 5x2,5 4x20
3x280V 10,8 6,5 30,1 4xAWG9 3x32
650 3Nx400V 19,5 11,7 28,1 5x4 4x32
3x280V 19,2 11,5 53,4 4xAWG7 3x63
C Electrical connection (qualied electrician’s inspection)
√For a correct connection during the installation:
• provide sockets connecting to the electrical network near the oven. If the oven has a double chamber, there must be two connecting sockets.
• use a cable and a plug: appliancesaresupplied without either powercableorplug: they must bothbefittedbyqualified personnel.Thecablemust be onlyof the type stated and the
plug fitted to it must be suitable for the consumption and connection of the oven to the electrical mains.
• check that the systems in the room comply with the legal provisions in force in the country of use and meet the specifications ontheserial numberplate.Foracorrectelectrical
connection, the appliance must:
• be included in an equipotential systemin compliance with the legislation in force. This connection must be made between the various devices with the terminal marked with the
equipotential symbol .The cable must have a maximum cross-section of 10 mm2(in compliance with IEC EN 60335-2-42:2003-09) and must be yellow-green;
• must be grounded to the mains (green-yellow wire);
• must be connected to a thermal dierential switch in compliance with the regulations in force (0.03A A type);
• must be connected to an omnipolar circuit breaker allowing complete disconnection in overvoltage III category conditions.