enGage II: Programmable Maintenance Monitor
3003R-67X-0001
Description AMP
Pin #
(V+) Supply voltage positive
terminal
4
(V-) Supply voltage negative
terminal
8
Key switch (+): When V+ is
applied this switch operates the
gauge display
.
6
MOSFET output: MOSFET
(0.5A) open drain type internally
tied to V-.
7
Setup Enable (+): When V+
applied, gauge can be
programmed via panel buttons.
2
Hour Meter Enable (+): When
V+ applied, accumulation of
time occurs when key switch on.
3
Technical Specifications
Operating Voltage Range 12V-48VDC nominal voltage, +/-
25%
Operating Current Range Nominal- 14 mA, maximum 20
mA. Values reflect key switch in "on" position
Display: LCD with 10-segment bar and 5 digit numeric
(5mm high)
Hour Meter Range 9,999.9 Maintenance Hours
& Resolution: 99,999 Total Hours
Hardware: Mounting Bracket
Panel Cutout: 52 mm / 2 1/16" diameter
Shock SAE J 1378 Amplitude
44-55 g, half sine, 9-13 ms duration
Vibration SAE J 1378 Double amplitude of 1.53mm with
frequency sweep for 10-80-10 Hz (20 g max) at 1 minute
intervals
Storage Temperature: -50°C to +90°C
Operating Temperature: -40°C to +85°C
Humidity: 95% RH (non-condensing)
IP Rating: 65 Front & Rear with AMP connector installed
1
2 / 5
2 / 5

Distributor of Curtis Instruments: Excellent Integrated System Limited
Datasheet of 3003R-67X-0001 - VOLTMETER 12-48VDC LCD PANEL MT
2
Configuration Notes
The gauge remains in configuration mode for 30
seconds without input from the user. When configuring
each function (time-of-day, maintenance interval, etc.),
you must enter in all data for that function for it to be
saved. If incomplete data is entered for a function and
the programming mode is timed out (after 30 seconds
of no input received by the gauge), the gauge will
revert back to what was previously stored for that item.
1 0
Exiting Configuration Mode
The configuration mode can be exited in three ways:
1. Press and hold the left button for three seconds.
2. Leave buttons untouched for 30 seconds.
3. Press the left button after selecting the last (right)
digit of the last function available.
Operation
When the main power (9-60 VDC) is applied to V+ and
V-, a power-up sequence is initiated. All display
segments are illuminated for one second. The display
is then turned off until the key switch is activated.
Toggling Display Functions
Press the left button to sequentially toggle between the
two numeric gauge functions (time-of-day clock,
maintenance hours).
Resetting the Maintenance Hour
Meter
This can be done without V+ applied to Setup Enable
pin. Press the left button until the maintenance hour
meter function is displayed (the wrench icon will be
illuminated). Press and hold both the right button and
the left button until the display flashes and the
maintenance hour meter is reset to the preset
maintenance period. Release the right button first. This
reset function can be performed at any time,
independent of the actual maintenance status.
Configuring Your Gauge
Access to these operations is sequential in this order.
Adjustments of the following functions can be
performed in the Configuration Mode:
1. Time-of-Day Clock
2. Maintenance interval
During configuration, the right button is used to
increment. The left button is used to:
1. Enter a selection
2. Advance to the next configurable item
If no change is desired to a specific gauge function,
continue to press the left button until the next desired
function is reached. The time-of-day clock is entered
by setting the hours digits between 01 and 12, then
"minutes" digits between "00" and "59".
The maintenance interval (when the gauge signals that
maintenance is due) is configurable and should be set
after the initial installation. The interval can be set
between 1 and 9,999 hours in 1 hour increments.
Setting the Maintenance Interval
Apply V+ (9 to 60VDC to the set up enable pin (2).
Press and hold the Left button on the front panel until
the display flashes and then release. The display will
flash the two "Hours" digits , Press the left button
once. The display will flash the two "Minutes" digits ,
Press the left button once. The display will flash the
maintenance left digit (thousands of hours). Press the
right button to increment by one or hold the button to
increment continuously. When the desired number is
reached, press the left button once to proceed to the
next digit. Repeat this process for all 4 digits. , Press
the left button once to exit.
Setting the Time-of-Day Clock
This can be done without V+ applied to Setup Enable
pin. Press and hold the left button on the front panel
until the entire display flashes and then release.
The display will flash the two "Hours" digits. Press the
right button to increment by one hour, or hold the
button to increment continuously. When the desired
number of hours is reached, press the left button once.
The display will flash the two "Minutes" digits. Press
the right button to increment by one minute or hold the
button to increment continuously. When the desired
number of minutes is reached, press the left button
once.
3 / 5
3 / 5

Distributor of Curtis Instruments: Excellent Integrated System Limited
Datasheet of 3003R-67X-0001 - VOLTMETER 12-48VDC LCD PANEL MT
Maintenance
The enGage™II 3000 Series is not serviceable.
Safety Instructions
This instrument was manufactured and tested
according to the applicable technical standards. It
complies with all the safety regulations as shipped
from the factory.
Installation and startup must be performed by skilled
personnel.
Failure to install and operate the unit in accordance
with these instructions may result in damage or injury.
If safe operation of the instrument can no longer be
ensured, stop and secure it against accidental
operation.
If instrument failure or malfunction may cause
personal injury or material damage, use additional
safety measures such as limit switches, guards, etc.
Read the Operating Instructions carefully before
startup.
Note the safety instructions marked with this
warning symbol in this manual.
Guarantee
Curtis Instruments’ products and/or components are
guaranteed against defects in workmanship and
material for a period of two years, or as defined in the
individual product literature, from date of shipment
from our factory, when applied in a proper application
within specified ratings. This guarantee is limited to
repair or replacement F.O.B. our factory. There is no
further warranty or implied representation, guarantee,
promise or agreement as to any Curtis Instruments
product and/or component. Curtis Instruments, Inc.,
cannot assume responsibility or accept invoices for
unauthorized repairs to its products and/or
components, even though defective. In no case will
Curtis Instruments’ responsibility extend to products,
components or equipment not of its manufacture.
Under no circumstances shall Curtis Instruments, Inc.
be liable for any special or consequential damages or
loss of profits or other damages. Returned goods will
not be accepted unless identified by a Curtis Return
Material Authorization (RMA). All specifications are
subject to change without notice.
LCD Icons
1. Hourglass Icon - Turned on (not blinking) to
indicate that an hour meter is displayed in the numeric
display. Flashes to indicate hour meter accumulation.
2. Wrench Icon - Turned on (not blinking) to
indicate that the maintenance hour meter is displayed
in the numeric display. Flashes when the maintenance
interval is reached.
3. Colon - Flashes to indicate that the time-of-
day clock is being displayed in the numeric display and
that time is counting-up.
4. Decimal Point - To indicate 1/10 of an hour on
the maintenance hour meter
5. Percent - Indicates remaining percentage of
interval or level.
Troubleshooting
Maintenance Monitor Function
Problem
Possible Cause
Will not reset
Resetting
procedure not being
followed
Will not/can not configure
maintenance interval No Power to set up
enable pin
Notes
1. Mating connector; 8-pin AMP, P/N 794821-1
with UL rating 94V-0. Interface seal, P/N
794772-0. Wire seal 794758-1, Pins
P/N770904-X for #18-24 AWG.
2. Material: Case-polycarbonate, lens-clear
polymethylmethacrylat (PMMA) cover,
overlay and mounting bracket-polycarbonate.
3. This unit is designed for a mounting panel
thickness of 0.8mm-6.4mm.
4. Panel cutout: 52mm diameter dash panel
hole.
3
4 / 5
4 / 5

Distributor of Curtis Instruments: Excellent Integrated System Limited
Datasheet of 3003R-67X-0001 - VOLTMETER 12-48VDC LCD PANEL MT
Installation
Caution!
Bracket has been designed to remain secured to the
gauge upon proper installation. Once installed
correctly, attempts to remove bracket from gauge
may result in damage to the bracket.
Curtis enGage™ II instruments are mounted in a
52mm round cutout. Serrations on the barrel of the
gauge, combined with the mounting bracket
provided, insure fast and trouble free installation. To
insure proper installation, the 2 locking tabs on
either side of the inner diameter of the bracket
should aligned with the serrations on the barrel of
the gauge (see drawing above). Next, slide the
bracket over the barrel of the gauge and press it
firmly against back of panel. You should hear the tab
sliding over the serrations.
Curtis enGage™ II mates with an 8-pin AMP
connector (AMP pins P/N 770904-X FOR #18-24
AWG P/N 794821-1).
A preassembled mating connector kit (Curtis P/N
17631800-01) with crimp-connect terminated wires
(approx. 5 inches in length) is also available.
Output and Warning LED
Function
LED
Activated
FET
Shut off
Maintenance
Due
LMB
LMB
KEY
1. RMB = Right Most LCD Bar
2. LMB = Left Most LCD Bar.
Installation Procedure
1. Mount unit in standard SAE round cutout.
2. Connect supply voltage to pins indicated: (V+) pin
4, (V-) pin 8.
3. Connect pin 6, as appropriate for key switch, to
enable gauge display.
4. Connect pin 3 as appropriate to activate the hour
meter.
5. Connect pin 2 to a hidden enable switch.
6. Connect pin 7 to an audio, visual, horn, or other
warning device (load). Caution:Max current draw on
warning device is 0.5 Amps.
4
Powered by TCPDF (www.tcpdf.org)
Powered by TCPDF (www.tcpdf.org) 5 / 5
5 / 5
This manual suits for next models
1
Table of contents
Other Curtis Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Sensitech
Sensitech TempTale RF Instructions for use

Agilent Technologies
Agilent Technologies G7035A Operation manual

Rae
Rae MiniRAE 2000 PGM-7600 Operation and maintenance manual

Eurochron
Eurochron WS4003 operating instructions

ILX Lightwave
ILX Lightwave FPM-8200 user guide

Pitney Bowes
Pitney Bowes DM400c series Return Instructions