CyberData 11095 Manual

Quick Reference 930342E © 2014, CyberData Corporation, ALL RIGHTS RESERVED© 2014, CyberData Corporation, ALL RIGHTS RESERVED 930342E Quick Reference
Connections
Mounting the Enclosure
Contacting CyberData
1-Sense (+)
2-GND
3-Relay COM
4-Relay NO
5-Line-In(+)
6-Line-In(-)
7-Line-Out(+)
8-Line-Out(-)
9-Spkr Out(+)
10-Spkr Out (-)
CLASS II WIRING
Speaker Connection
Line-Out Connection
Relay Connection
Sensor Connection
Line-In Connection
To mount the enclosure:
1. Prepare holes for the screws.
2. Plug in the power adapter and use the
green Power light to verify that the
power is on.
3. Plug the Ethernet cable into the V2
Loudspeaker Amplifier. The yellow Link
light verifies the network connection.
4. For wall mounting, use the three
#6 x 1-1/4-inch Pan Head Phillip screws
to secure the speaker.
071057A
PHILLIP SCREW (3x)
#6x1 1/4" PAN HEAD
#6 PLASTIC ANCHOR (3x)
151014
531032
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Web: http://www.cyberdata.net/support/contactsupportvoip.php
RMA Dept: (831) 373-2601 ext. 136
Email: [email protected]
RMA Status: http://www.cyberdata.net/support/rmastatus.html
Warranty information is available at:
Web: http://www.cyberdata.net/support/warranty/index.html
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
www.CyberData.net
Getting Started
• Download the VoIP V2 Loudspeaker Amplifier Operations Guide PDF file from the Documents page at:
http://www.cyberdata.net/products/voip/digitalanalog/loudspeakerampv2/docs.html
• Create a plan for the locations of your paging amplifiers.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the
installation instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: The V2 Loudspeaker Amplifier enclosure is not rated for any AC voltages!
Wiring the 125V AC Plug
V2 Loudspeaker Amplifier Parts
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa
a. Default if there is not a DHCP server present.
10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
The green wire with the yellow stripe is a ground connection for Electrostatic Discharge (ESD) protection,
and should not be removed.
To wire the 125V AC plug, consult a licensed electrician and the local building codes in your area.
(1) Assembly (1) Wall Mounting Kit
(3) #6 Plastic Anchors (3) #6 x 1-1/4-inch Pan Head Phillip Screws
(1) Enclosure
(1) CAT 5e/CAT6 cable
Additional Parts View Inside of the Enclosure
(1) PoE Power Injector
Installation Quick Reference
VoIP V2 Loudspeaker Amplifier
(AC-Powered)
SIP Compliant
011095
The IP Endpoint Company
© 2014, CyberData Corporation, ALL RIGHTS RESERVED 930342E Quick Reference Quick Reference 930342E © 2014, CyberData Corporation, ALL RIGHTS RESERVED
7.938
[201.63]
6.281 [159.54]
Dimensions are in Inches [Millimeters]
Features
DIP Switch Settings
DIP Switches
Speaker Volume
Network Link LED (GREEN/YELLOW)
Status LED (GREEN)
A steady LED confirms that the V2 Loudspeaker Amplifier is oper-
ational. The LED will blink during a page when it is online.
Network Activity LED (GREEN)
Power LED (GREEN/BLUE)
The power LED is a steady green in low power mode and a steady blue during high power
mode. The power LED will only blink either during a boot up or a phone call.
RTFM Switch
To broadcast a V2 Loudspeaker Amplifier’s current IP address, press and hold the RTFM switch
for a couple of seconds and then release it.
To restore the factory defaults, complete the following steps:
1. Press and hold the RTFM switch until you hear the V2 Loudspeaker Amplifier announce the
words, “restoring defaults” and “rebooting”.
2. Release the RTFM switch. The V2 Loudspeaker Amplifier will be restored to the factory
default settings.
DIP Switch Settings—Low Power—802.3af Compliant
DIP Switch Setting Description
1 OFF Sets PoE for 802.3af class.
2 N/A Not applicable for power setting.
3 ON Switch mode current set to LOW.
4 OFF Low gain amplifier setting.
DIP Switch Settings—High Power—802.3at (Default)a
a. If set to high power, the unit will not power ON with 802.3af compliant switch. You must use a
power injector in this mode (CyberData part number 011124).
DIP Switch Setting Description
1 ON Sets PoE for 802.3at class.
2 N/A Not applicable for power setting.
3 OFF Switch mode current set to HIGH.
4 ON Force high gain amplifier.
DIP Switch 2 Settings
DIP Switch Setting Description
2OFFManual Vol. The speaker volume is set manually by the analog
volume trimmer.
2ONBypass. Bypasses the manual volume control of the analog volume
trimmer and uses the web page volume settings.
Dimensions and Mounting Template
14.500
[368.30]
10.875 [276.23]
4.375
[111.13]
Cable Grommets (3 PLCS)
Dimensions are in Inches [Millimeters]

Other manuals for 11095

3

Other CyberData Amplifier manuals

CyberData 11114 Manual

CyberData

CyberData 11114 Manual

CyberData 011324 User manual

CyberData

CyberData 011324 User manual

CyberData 11097 User manual

CyberData

CyberData 11097 User manual

CyberData 11095 User manual

CyberData

CyberData 11095 User manual

CyberData VoIP Loudspeaker Amplifier Part #010859 User manual

CyberData

CyberData VoIP Loudspeaker Amplifier Part #010859 User manual

CyberData 930112A User manual

CyberData

CyberData 930112A User manual

CyberData 11085 User manual

CyberData

CyberData 11085 User manual

CyberData 011404 Manual

CyberData

CyberData 011404 Manual

CyberData 11097 Manual

CyberData

CyberData 11097 Manual

CyberData InformaCast Enabled 011406 Manual

CyberData

CyberData InformaCast Enabled 011406 Manual

CyberData 011403 Manual

CyberData

CyberData 011403 Manual

CyberData 10860 User manual

CyberData

CyberData 10860 User manual

CyberData 011579 User manual

CyberData

CyberData 011579 User manual

CyberData 11095 User manual

CyberData

CyberData 11095 User manual

CyberData InformaCast Enabled 011407 User manual

CyberData

CyberData InformaCast Enabled 011407 User manual

CyberData 011403 User manual

CyberData

CyberData 011403 User manual

CyberData 010861 930106A User manual

CyberData

CyberData 010861 930106A User manual

CyberData 11097 User manual

CyberData

CyberData 11097 User manual

CyberData VoIP Paging/Loudspeaker Amplifier User manual

CyberData

CyberData VoIP Paging/Loudspeaker Amplifier User manual

CyberData 011404 User manual

CyberData

CyberData 011404 User manual

CyberData VoIP V2 User manual

CyberData

CyberData VoIP V2 User manual

CyberData 011403 User manual

CyberData

CyberData 011403 User manual

CyberData 11095 User manual

CyberData

CyberData 11095 User manual

CyberData 011405 Manual

CyberData

CyberData 011405 Manual

Popular Amplifier manuals by other brands

Bogen Flex-Pak CHS-35A user manual

Bogen

Bogen Flex-Pak CHS-35A user manual

Shireen 18-850 installation manual

Shireen

Shireen 18-850 installation manual

Rockville RPA-5 owner's manual

Rockville

Rockville RPA-5 owner's manual

YBA DESIGN PH100 owner's manual

YBA DESIGN

YBA DESIGN PH100 owner's manual

Magnatone Twilighter user guide

Magnatone

Magnatone Twilighter user guide

FAST ComTec CSPA10 user manual

FAST ComTec

FAST ComTec CSPA10 user manual

Gefen DVI-248 user manual

Gefen

Gefen DVI-248 user manual

Teledyne SSPA quick start guide

Teledyne

Teledyne SSPA quick start guide

Hughes & Kettner TRIAMP manual 

Hughes & Kettner

Hughes & Kettner TRIAMP manual 

Teledyne SSPA manual

Teledyne

Teledyne SSPA manual

Channel Vision A0240 instructions

Channel Vision

Channel Vision A0240 instructions

THD BiValve-30 user guide

THD

THD BiValve-30 user guide

Kenwood KAC-7251 instruction manual

Kenwood

Kenwood KAC-7251 instruction manual

Mark Levinson 536 manual

Mark Levinson

Mark Levinson 536 manual

Yamaha AX-496 Service manual

Yamaha

Yamaha AX-496 Service manual

Audio Research Reference 5 SE owner's manual

Audio Research

Audio Research Reference 5 SE owner's manual

PCB Piezotronics 426A07 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 426A07 Installation and operating manual

Technalogix TAV-100 manual

Technalogix

Technalogix TAV-100 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.