manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberData
  6. •
  7. Intercom System
  8. •
  9. CyberData 011211 series Manual

CyberData 011211 series Manual

Quick Reference 930814K © 2017, CyberData Corporation, ALL RIGHTS RESERVED© 2017, CyberData Corporation, ALL RIGHTS RESERVED 930814K Quick Reference
Wall Mounting Options
Gang Box Mounting Options
Mounting Screw &
Wall Cutout
on Wall
Pre Drill Holes
to J1
Cable
Network
Backplate
Plastic Ribbed Anchor
Remove Screw & Nut
Before Install to Wall
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Wire
Ground
Closed
Slots
Slots
Opening
Slot
Entry
Cable
Wall Cutout
or Two Gang Box
Backplate accept
Single Gang Box
Backplate
Wall Cutout
Wire
Ground
Two Gang Box use four
Single Gang Box use two
Screw Accessory Kit
In Two Gang Box Mounting
Move Ground Cable to Center Hole
Remove Screw & Nut
Before Install to Gang Box
Mounting
Screw (3x)
Loop Wire
Clockwise
Wire
Ground
Cable
Network
Closed
Slots
Cable
Slot
Entry
Cable
Getting Started
• Download the Operations Guide PDF file, from the Downloads tab at the following webpage:
http://www.cyberdata.net/voip/011211/
• Create a plan for the locations of your Intercoms.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Parts
Contacting CyberData
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
(4) Plastic Ribbed Anchor (4) #6-32 FlatHead Countersunk
Machine Screw
(1) Wall Mounting Kit(1) Intercom Assembly (1) Gang Box Mounting Kit
(4) Sheet Metal Screw
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
The IP Endpoint Company
Installation Quick Reference
SIP Indoor Intercom
SIP Compliant
011211*, RAL 9003, Signal White
*Replaces the 011111 number.
© 2017, CyberData Corporation, ALL RIGHTS RESERVED 930814K Quick Reference Quick Reference 930814K © 2017, CyberData Corporation, ALL RIGHTS RESERVED
RTFM Button
Maximum Recommended Wall Cutout Dimensions
RTFM button (SW1)
When the device is operational and linked to a net-
work, you can use the Reset Test Function Man-
agement (RTFM) button (SW1 [see picture]) to
announce the device’s IP address or restore the
device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a
five second window.
Note The device will use DHCP to obtain the
new IP address (DHCP-assigned address
or default to 10.10.10.10 if a DHCP server
is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer
than five seconds until you hear the device
announce that it is restoring the factory default
settings.
DIMENSIONS ARE IN INCHES [MILLIMETER]
3.40 [86.4]
ø0.19 [ø4.8]
2.39 [60.8]
3.40 [86.4]
2.65 [67.3]
0.50 [12.8]
0.38 [9.5]
(4 Places)
Dimensions
Terminal Block Connections
4.53 [115.0]
4.53 [115.0]
DIMENSIONS ARE IN INCHES [MILLIMETER]
2.14 [54.3]
0.25"
Terminal Block
Wire (IN)
can accept 16 AWG wire
1
8
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Relay Common
4 = Relay Normally Open Contact
5 = Sense Input
6 = Sense Ground
7 = Remote Switch "A"
8 = Remote Switch "B"
*Contacts 1 and 2 on the terminal block are only for
powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
Use a 3.17 mm (1/8-inch) flat blade
screwdriver for the terminal block screws

Other manuals for 011211 series

3

Other CyberData Intercom System manuals

CyberData 11209 Manual

CyberData

CyberData 11209 Manual

CyberData 11310 User manual

CyberData

CyberData 11310 User manual

CyberData 3COM VCX PBX Server User manual

CyberData

CyberData 3COM VCX PBX Server User manual

CyberData 11272 Manual

CyberData

CyberData 11272 Manual

CyberData 11113 User manual

CyberData

CyberData 11113 User manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData 011414 Manual

CyberData

CyberData 011414 Manual

CyberData 11310 Manual

CyberData

CyberData 11310 Manual

CyberData 011307 Manual

CyberData

CyberData 011307 Manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11305 Manual

CyberData

CyberData 11305 Manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 011311 Manual

CyberData

CyberData 011311 Manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData V3 Keypad User manual

CyberData

CyberData V3 Keypad User manual

CyberData 011035 Manual

CyberData

CyberData 011035 Manual

CyberData #011123 Manual

CyberData

CyberData #011123 Manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData 11305 User manual

CyberData

CyberData 11305 User manual

Popular Intercom System manuals by other brands

Zennio GetFace IP ZVP-FFRA2 Assembly instructions

Zennio

Zennio GetFace IP ZVP-FFRA2 Assembly instructions

Aiphone GH-1KD specification

Aiphone

Aiphone GH-1KD specification

Commax DRC-8TML/RF1 user manual

Commax

Commax DRC-8TML/RF1 user manual

ABB 83210-AP 500 Series manual

ABB

ABB 83210-AP 500 Series manual

TIS TIP-DPH-INT7 user manual

TIS

TIS TIP-DPH-INT7 user manual

Bell System bellview Installation & operation manual

Bell System

Bell System bellview Installation & operation manual

SynerTech 1 family Installation and operation manual

SynerTech

SynerTech 1 family Installation and operation manual

KOCOM KDP-602G user manual

KOCOM

KOCOM KDP-602G user manual

Fermax LOFT Extra DUOX quick start guide

Fermax

Fermax LOFT Extra DUOX quick start guide

X-Vision XAM300H instruction manual

X-Vision

X-Vision XAM300H instruction manual

TCS Carus Adapto instruction manual

TCS

TCS Carus Adapto instruction manual

Telecom Behnke myintercom instructions

Telecom Behnke

Telecom Behnke myintercom instructions

LEGRAND Easy Kit Connected installation manual

LEGRAND

LEGRAND Easy Kit Connected installation manual

Videx CVR4KV owner's manual

Videx

Videx CVR4KV owner's manual

Commax DRC-4BA user manual

Commax

Commax DRC-4BA user manual

Hubbell GAI-TRONICS SP2 Quick installation guide

Hubbell

Hubbell GAI-TRONICS SP2 Quick installation guide

urmet domus 1148 Series Installation, programming and functions manual

urmet domus

urmet domus 1148 Series Installation, programming and functions manual

Honeywell ETCS operation instruction

Honeywell

Honeywell ETCS operation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.