Quick Reference 930520G © 2015, CyberData Corporation, ALL RIGHTS RESERVED© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930520G Quick Reference
Connecting the Keypad Intercom (Service Loop Routing)
Securing the Intercom
Contacting CyberData
Ground Cable Installation Network Cable Installation
Ground Cable
(not provided)
Ground Lug
Nut (to Ground Lug
inside of the Gang Box
Route cable(s) inside of the
Gang Box to create the service loop. Route cable(s) inside of the
Gang Box to create the service loop.
Network Cable
(not provided)
Torx Key
Torx Screws
3-Gang Box
Faceplate &
PCB Assembly
GENERAL ALERT
Note: To mount the intercom, use methods
compliant with local electrical codes.
Caution
Equipment Hazard: Do not use an electric or power
screwdriver to fasten the face plate and PCB assembly to the
gang box. To prevent over-torque damage to the gasket, do
not apply more than 10 inch-pounds force. Over-torquing
will cause the gasket to tear, risk moisture intrusion, and
effectively void the manufacturer's warranty.
Note: More installation and mounting
information is illustrated in the Keypad
Intercom Operations Guide.
Sales: (831) 373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: (831) 373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Typical System Installation
Getting Started
• Download the Operations Guide PDF file from the Documents page at:
http://www.cyberdata.net/products/voip/digitalanalog/intercomkeypadv3/index.html
• Create a plan for the locations of your Keypad Intercoms.
• WARNING: This product should be installed by a licensed electrician according to all local electrical and building codes.
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
•WARNING: This enclosure is not rated for any AC voltages!
Keypad Intercom Parts
Parameter Factory Default Setting
IP Addressing DHCP
IP Addressa10.10.10.10
Web Access Username admin
Web Access Password admin
Subnet Maska255.0.0.0
Default Gatewaya10.0.0.1
a. Default if there is not a DHCP server present.
Door Strike VoIP Intercoms with Keypad IP Phone IP PBX Server
Generic PoE Switch
12 34 56
*More installation and mounting
information is illustrated in the
Operations Guide.
Accessories
Spacer for Half-inch Set Screw Connector
531085B Hole Plug Assembly
Accessory Kit Security Torx MS
Accessory Kit
Carriage Bolt Bolts
Carriage Bolt Nuts
Carriage Bolt Washers
Mounting Component Security Torx Key
(1) Intercom Assembly
Installation Quick Reference
VoIP Outdoor Keypad Intercom
SIP Compliant
011214
The IP Endpoint Company
© 2015, CyberData Corporation, ALL RIGHTS RESERVED 930520G Quick Reference Quick Reference 930520G © 2015, CyberData Corporation, ALL RIGHTS RESERVED
Terminal Block Connections
RTFM Button
7.480 [190.00]
DIMENSIONS ARE IN INCHES [MILLIMETER]
2.284 [58.01]
5.118 [130.00]
5.198 [132.03]
Call Button
Microphone
Hole
Speaker
Drain Hole
Features Dimensions (Front and Side View)
J3 Terminal Block
Wire (IN)
Terminal Block
can accept
16 AWG wire
Alternate Power Input:
1 = +12 to +24 VDC at 1000 mA
2 = Power Ground
Relay Contact:
(1A at 30 VDC for Continuous L
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Refere
34
(500 mA Minimum)
Alternate Power Input:
1 = +8 to +12VDC @ 1000mA Regulated Power Supply*
2 = Power Ground*
Relay Contact:
(1 A at 30 VDC for continuous loads)
3 = Normally Open Common
4 = Normally Open Contact
5 = Door Sense Input
6 = Door Sense Ground Reference
*Contacts 1 and 2 on the J3 terminal block are only
for powering the device from a non-PoE 12VDC power
source as an alternative to Network PoE power. Use of
these contacts for any other purpose will damage the
device and void the product warranty.
34
When the device is operational and linked to a network,
you can use the Reset Test Function Management
(RTFM) button (SW1 [see picture]) to announce the
device’s IP address or restore the device to the factory
default settings.
To announce the device’s current IP address:
• Press and release the RTFM button within a five
second window.
Note The device will use DHCP to obtain the new IP
address (DHCP-assigned address or default to
10.10.10.10 if a DHCP server is not present).
To restore the device to factory default settings:
• Press and hold the RTFM button for longer than five
seconds until you hear the device announce that it is
restoring the factory default settings.
SW1
Dimensions (Rear View and Mounting Holes)
Conduit Mounting Restrictions (Rear Entry)
ø0.280 [ø7.11]
3.740 [95.00]
1.690 [42.93]
0.869 [22.07]
3.380 [85.85]
1.690
(3 Places)
[42.93]
ø0.854 [ø21.69]
Dimensions are in Inches [Millimeter]
1/2" Conduit
(Not Provided)
Here Connector
1/2" Conduit
(Not Provided)
Cable
Network
Spacer
Add
(Not Provided)
Cable
Network
(Not Provided)
1/2" Conduit
1/2" Conduit
Spacer Connector
(Not Provided)
(Not Provided)
Here
Add
With Shroud Without Shroud

Other manuals for 11214

6

Other CyberData Intercom System manuals

CyberData VoIP Indoor Intercom 011030 Manual

CyberData

CyberData VoIP Indoor Intercom 011030 Manual

CyberData 11186 User manual

CyberData

CyberData 11186 User manual

CyberData 11304 User manual

CyberData

CyberData 11304 User manual

CyberData 011410 Manual

CyberData

CyberData 011410 Manual

CyberData 11307 User manual

CyberData

CyberData 11307 User manual

CyberData 011309 User manual

CyberData

CyberData 011309 User manual

CyberData 11304 User manual

CyberData

CyberData 11304 User manual

CyberData 11186 Manual

CyberData

CyberData 11186 Manual

CyberData 3CX User manual

CyberData

CyberData 3CX User manual

CyberData 11186 Manual

CyberData

CyberData 11186 Manual

CyberData 011307 Manual

CyberData

CyberData 011307 Manual

CyberData 011478 Manual

CyberData

CyberData 011478 Manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData 11214 User manual

CyberData

CyberData 11214 User manual

CyberData VoIP Desktop Intercom Manual

CyberData

CyberData VoIP Desktop Intercom Manual

CyberData #011123 Manual

CyberData

CyberData #011123 Manual

CyberData 11113 Manual

CyberData

CyberData 11113 Manual

CyberData 11272 Manual

CyberData

CyberData 11272 Manual

CyberData 11035 User manual

CyberData

CyberData 11035 User manual

CyberData 011211 series Manual

CyberData

CyberData 011211 series Manual

CyberData V3 Keypad User manual

CyberData

CyberData V3 Keypad User manual

CyberData 11111 User manual

CyberData

CyberData 11111 User manual

CyberData VoIP Indoor Intercom 011030 User manual

CyberData

CyberData VoIP Indoor Intercom 011030 User manual

CyberData 011530 Manual

CyberData

CyberData 011530 Manual

Popular Intercom System manuals by other brands

Algo 3006 installation guide

Algo

Algo 3006 installation guide

Auta 760595 manual

Auta

Auta 760595 manual

KOCOM KC-MC35 user manual

KOCOM

KOCOM KC-MC35 user manual

Aiphone JP Series installation guide

Aiphone

Aiphone JP Series installation guide

SSS Siedle Siedle Steel STLM 645-02 Product information

SSS Siedle

SSS Siedle Siedle Steel STLM 645-02 Product information

Bticino 364235 installation manual

Bticino

Bticino 364235 installation manual

Eyevision EV-IP-KP22 user manual

Eyevision

Eyevision EV-IP-KP22 user manual

3M HEADSET C1060 Replacement parts list

3M

3M HEADSET C1060 Replacement parts list

Aiphone TA-12H instructions

Aiphone

Aiphone TA-12H instructions

Vimar ELVOX 6570 Installer's guide

Vimar

Vimar ELVOX 6570 Installer's guide

Commax CDV-50P manual

Commax

Commax CDV-50P manual

Aiphone GT-1M3 Operation guide

Aiphone

Aiphone GT-1M3 Operation guide

Fermax iLOFT VDS Extra manual

Fermax

Fermax iLOFT VDS Extra manual

Sigtronics US-12S Installation and operating instructions

Sigtronics

Sigtronics US-12S Installation and operating instructions

KOCOM KC-MB20 user manual

KOCOM

KOCOM KC-MB20 user manual

Aiphone GT-1M-L Service manual

Aiphone

Aiphone GT-1M-L Service manual

PS Engineering PMA7000B Series Pilot's guide and operation manual

PS Engineering

PS Engineering PMA7000B Series Pilot's guide and operation manual

Genway 2018D user manual

Genway

Genway 2018D user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.