Quick Reference 931350C © 2020, CyberData Corporation, ALL RIGHTS RESERVED© 2020, CyberData Corporation, ALL RIGHTS RESERVED 931350C Quick Reference
Getting Started
Take the following into consideration before you install this product:
• When this secure phone case is used, the touch screen capability of the DX phone is disabled.
• Due to the size and mass of this product, it is important that the Backbox is safely installed according to these installation
instructions.
• Make sure that the type of wall is capable of supporting the system and use screws that are suitable for that type of wall.
• The system must be installed by qualified personnel in accordance with state and local building regulations.
• Also see the Install the DX70 Phone to Enclosure (on the other page).
• Locate the provided Security Torx Driver Bit (usually taped right next to the Hookswitch on the Faceplate).
• Tool required to remove Security Torx Screws (an Electric Hand Drill or Powered Screwdriver)
• WARNING: To prevent injury, this apparatus must be securely attached to the floor/wall in accordance with the installation
instructions.
• WARNING: The PoE connector is intended for intra-building connections only and does not route to the outside plant.
• WARNING: This enclosure is not rated for any AC voltages!
Hookswitch Wires to USB to Analog Audio Module Connections
Contacting CyberData
Black Wire
to Terminal
Black Wires
110
USB-B
Black Wire to Terminal
Green Wire to Terminal
Yellow Wire to Terminal
Red Wire to Termianl
Terminal
Audio Module
USB to Analog
Block
Armored Cord
Armored Cord
Handset Retainer
Factory Disconnected
to Terminal 5
Red Wire
Connections
Reconnect Before Fasten Faceplate Assembly to Backbox
Connector
Receptacle
Connector
Plug
Magnetic Hookswitch Backbox
***
***
Connections
Armored Cord Handset
9
4
3
2
1
USB-A
Phone
Cable Connections
USB-B to USB-A
Sales: 831-373-2601 ext. 334
Support: 831-373-2601 ext. 333
Support Website: http://support.cyberdata.net/
RMA Department: 831-373-2601 ext. 136
RMA Email: [email protected]
RMA Status: http://support.cyberdata.net/
Warranty Information: http://support.cyberdata.net/
Corporate Headquarters
CyberData Corporation
3 Justin Court
Monterey, CA 93940, USA
Phone: 831-373-2601
Fax: 831-373-4193
http://www.cyberdata.net/
Backbox Mounting
Install a Shunt on JP2 to Enable Auto Answer Mode
Dimensions are in Inches [Millimeter]
Conduit Hole Ø 1.3 [Ø33] Fits 1" EMT Fittings
Ø1.3 [Ø33]
Conduit Hole
1.969 [50.0]
4.026 [102.3]
6.212 [157.8]
1.969 [50.0]
2.362 [60.0]
14.173 [360.0]
17.717 [450.0]
2.165 [55.0]
19.685 [500.0]
13.386 [340.0]
6.496 [165.0]
Ø0.41 [Ø10.5]
Last Updated 08/06/2020
View Shown with Hole Plug Installed.
Open Faceplate then Remove Nut from the Inside.
11/32" or 9mm Socket & Socket Wrench
Tool Required to Remove Hole Plug:
JP2
Shunt
The IP Endpoint Company
Installation Quick Reference
DX70 Secure Phone
011388
© 2020, CyberData Corporation, ALL RIGHTS RESERVED 931350C Quick Reference Quick Reference 931350C © 2020, CyberData Corporation, ALL RIGHTS RESERVED
Install the DX70 Phone to Enclosure
Use a Paper Clip Through Hole
HOOK
RECEIVER
1) Unsnap to Remove Both Plastic Pieces Above Connector Panel
Mic
Hole
PIN
PIN
2) Place Power Adapter in to Power Adapter Holder
2a) Insert Power & Ethernet Cables Through AnyDesired Conduit
4) Place PINS onto Hook Receiver on Backbox
4a) At the Same Time, Place the Camera onto FoamHolder
2b) Connect Cables (Power, Ethernet, USB, etc.) to Connector Panel
Cover Hole with Provided
Torx Button Socket Cap Screw &
T15 Torx Driver Bit
3) Connect the USB - A to B Cable:
HOOK
RECEIVER
4b) Place Foot Stand onto Power Adapter Holder
USB-B to USB to Analog Audio Module (UAAM), USB-A to Phone
5) Connect Wires fromArmored Cord Handset &
Hookswitch to Terminal Block on UAAM
BACKBOX
6a) Lift Foot Stand Upward with Left Hand,
6b) Grasp the Upper Right Corner of the Phone with Right Hand
Still Connected.
Camera
FoamHolder Hole Plug
Faceplate
Remove Phone fromBackbox SlowlyBecause Cables are
Cutout, Conduit Hole Ø 1.16 [Ø29.5] Fits 1" EMT Fittings
Speaker
Hole Cluster
11/32" or 9mm Socket & Socket Wrench
Tool Required to Remove Hole Plug:
KO
KO
Power Plug
DX70
(Customer Provided)
KO
Open Camera Shutter
1) Use Clean Damp Cloth to Wipe Surface Clean
Screen Cleaning Instruction:
KO
Place
Here
Power Supply
Power Cable
to AC Outlet
Phone Mounting Instruction:
Power Cord
Through Slot
Plexiglass Cleaning Instruction:
Plexiglass Cleaner to Wipe Surface Clean
Use Provided SecurityTorx
Driver Bit to Fasten Screws to Backbox
Tool Required:
Electric Hand Drill or
Powered Screwdriver
2) Screw Driver
1) Hammer
Tool Required to Remove Knock Outs (KO):
3) Plier
Self-Tapping Screw, Stud Anchors or
Fits up to 1/4" [10 mm] Square Neck Carriage Bolt,
Knock Outs (KO) & Keyholes:
Machine Screw
USB-B
Plug
Use Provided SecurityTorx
Driver Bit to Fasten Cover Screw
to Faceplate
Note #1
(See Note #1)
Power Adapter
Holder
USB-A
Plug
Power Adapter
(See Figure #3)
Figure #2 (See Also Figure #5)
Figure #3
(See Figure #4)
Figure #4
(See Figure #2)
Use Provided #00 Screw Driver
to Install Wires to Terminal Block
Turn Clockwise to
Remove Phone fromBackbox:
Ethernet
Foot Stand
1) Use onlylint Free Microber Tower &
Black Wire
to Terminal
Black Wires
110
USB-B
Black Wire to Terminal
Green Wire to Terminal
Yellow Wire to Terminal
Red Wire to Termianl
Terminal
Audio Module
USB to Analog
Block
Armored Cord
Armored Cord
Handset Retainer
FactoryDisconnected
to Terminal 5
Red Wire
Connections
Reconnect Before Fasten Faceplate Assemblyto Backbox
Connector
Receptacle
Connector
Plug
Magnetic Hookswitch Backbox
***
***
Connections
Armored Cord Handset
9
4
3
2
1
USB-A
Phone
Cable Connections
USB-B to USB-A
Audio Module
USB to Analog

This manual suits for next models

1

Other CyberData Telephone manuals

CyberData 011460 User manual

CyberData

CyberData 011460 User manual

CyberData RAL 9002 User manual

CyberData

CyberData RAL 9002 User manual

CyberData 011460 Manual

CyberData

CyberData 011460 Manual

CyberData 011049 User manual

CyberData

CyberData 011049 User manual

CyberData DX80 Manual

CyberData

CyberData DX80 Manual

CyberData DX80 Manual

CyberData

CyberData DX80 Manual

Popular Telephone manuals by other brands

THOMSON SPEEDTOUCH D51 user guide

THOMSON

THOMSON SPEEDTOUCH D51 user guide

Mitel MiVOICE 6930 user guide

Mitel

Mitel MiVOICE 6930 user guide

Avonic CM-MIC100 user manual

Avonic

Avonic CM-MIC100 user manual

Siemens Gigaset 3035 operating instructions

Siemens

Siemens Gigaset 3035 operating instructions

Grandstream Networks GXP2100 Quick reference guide

Grandstream Networks

Grandstream Networks GXP2100 Quick reference guide

Uniden DXI5586-3 Series owner's manual

Uniden

Uniden DXI5586-3 Series owner's manual

NEC Univerge SV8100 Quick reference guide

NEC

NEC Univerge SV8100 Quick reference guide

Yealink T42S-Skype for Business quick start guide

Yealink

Yealink T42S-Skype for Business quick start guide

Philips CD5301S/73 quick start guide

Philips

Philips CD5301S/73 quick start guide

GPO Carrington user guide

GPO

GPO Carrington user guide

Broadview OfficeSuite Administrator user guide

Broadview

Broadview OfficeSuite Administrator user guide

Topcom MAGIO 105 user guide

Topcom

Topcom MAGIO 105 user guide

GE TELSTRASATURN NZ 29393 user guide

GE

GE TELSTRASATURN NZ 29393 user guide

Yeastar Technology 3CX How to connect

Yeastar Technology

Yeastar Technology 3CX How to connect

Nytechco NP-500 manual

Nytechco

Nytechco NP-500 manual

ABRIVO AB-66218 user guide

ABRIVO

ABRIVO AB-66218 user guide

Profoon PDX-2808 user manual

Profoon

Profoon PDX-2808 user manual

Avaya 1400 Series Installation and maintenance guide

Avaya

Avaya 1400 Series Installation and maintenance guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.