manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberPower
  6. •
  7. UPS
  8. •
  9. CyberPower 600ELCD User manual

CyberPower 600ELCD User manual

Value 600ELCD/800ELCD/1000ELCD
User’s Manual Rev.A
SAFETY WARNINGS
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack,
install, or operate your UPS.
This equipment can be operated by any individuals with no previous training.
The socket-outlet shall be installed near the equipment and easily accessible.
During the installation of this equipment it should be assured that the sum of the leakage currents of the
UPS and the connected loads does not exceed 3.5mA.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole at the quick connectors of the battery when
maintenance or service work inside the UPS is necessary.
Do not dispose of batteries in a fire, the battery may explode.
Do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes.
INSTALLING YOUR UPS SYSTEM
UNPACKING
Inspect the UPS upon receipt. The box should contain the following:
UPS Unit1; USB Cable1; User Manual1; Management Ssoftware Disk1; Warranty Card x1
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Insure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS
unit’s rated capacity(600VA/360W for Value 600ELCD; 800VA/480W for Value 800ELCD;
1000VA/550W for Value 1000ELCD). If rated unit capacities are exceeded, an overload condition
may occur and cause the UPS unit to shut down or the fuse blow.
2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert
Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only
calculates the maximum amount of VA that the equipment can use, not what is typically used by the
equipment at any one time. Users should expect usage requirements to be approximately 60% of
below value.
TO ESTIMATE POWER REQUIREMENTS
1. Amps (A) x 230 = VA
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual
requirements. There are many factors that can affect the amount of power that your computer system
will require. The total load that you will be placing on the battery-powered outlets should not exceed
80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
Before installation, pleaseread and understand the following instructions:
1. Placement
The UPS must be installed in a protected environment away from heat- emitting appliances such
as a radiator or heat register. Do not install this product where excessive moisture is present.
2. Ventilation
The location should provide adequate air flow around the UPS with one inch minimum clearance
on all sides for proper ventilation.
3. Charge the Battery
Your new UPS may be used immediately upon receipt. However charge loss may occur during
shipping and storage. So charging the battery for at least 8 hours is recommended to insure that
the battery is fully charged. (To recharge the battery, simply leave the unit plugged into an AC
outlet.)
This UPS can be charged even when UPS is not turn on.
4. Connect to AC
Connect the UPS to a wall outlet. Please avoid using extension
cords and adapter plugs. (To maintain optimal battery charge,
leave the UPS plugged in at all times.)
5. Connect the Load
Connect the equipment to your UPS outlets. Items such as copiers, laser printers, vacuums,
space heaters,
or other large electrical devices SHOULD NOT be connected to the UPS. Please make sure
that the total loads of your equipments are less than the maximum total power load of your UPS.
6. Connect to Computer:
Install your software and accessories. To use the software, simply use the enclosed serial interface
or USB cable to connect the UPS unit and your computer.
BASIC OPERATION
FRONT PANEL DESCRIPTION
1. LCD Function Selected Switch
The switch can be used to select the LCD display contents including input/output voltage
and estimated run time, etc.
2. Power Switch
Press the power switch to turn the UPS ON or OFF.
3. LCD Status Monitor
REAR PANEL DESCRIPTION
1. Circuit Breaker
The circuit breaker provides optimal overload protection.
2. AC outlet
The UPS provides 2 outlets for connected equipment to insure temporary uninterrupted operation
during a power failure and against surges and spikes.
3. AC Inlet
Connect to utility power through the input power cord
4. Serial Port to PC
This port allows connection and communicates
from the DB-9 serial on the computer to the
UPS unit. The UPS communicates its status to
the PowerPanel® Personal Edition software.
This interface is also compatible with the UPS
service provided by Windows 98, Windows ME,
Windows NT, Windows 2000, Windows XP,
Windows Server 2003, Windows Vista, Windows 7.
5. USB Port to PC
This port allows connection and communication
from the USB port on the computer to the UPS
unit. The UPS communicates its status to the
PowerPanel™ Personal Edition software. This
interface is also compatible with the UPS service
provided by Windows 98, Windows ME,
Windows NT, Windows 2000, Windows XP,
Windows Server 2003, Windows Vista, Windows 7
NOTE: Only one of these two ports
can be used as communication and
control of the UPS unit at one time.
6. Communication Protection Ports
Communication protection ports will protect any standard modem, fax, telephone line,
FUNCTIONAL TEST
AC Mode
The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also
regulates the output voltage to within a narrow range.
On-Battery Mode
The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local
users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to
the load from the battery and through its inverter and the output voltage and frequency of the UPS are
regulated within a narrow range
1. Switch On
Press the power switch on the front panel then the status LCD will light up.
2. Switch Off
Press again the power switch, the status LCD on the front panel will go off.
3. Cold Start / Start on Battery:
This UPS can be turned on even whenAC is not present.
Press the power switch on the front panel then the status LCD will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1. Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that
contains alcoholic ingredient.
2. The expected lifetime of the battery is around 3 years. Improper operation and harsh environment
will reduce the actual lifetime.
3. Unplug the UPS from power inlet if the UPS will not operate for long period of time.
STORAGE
1. First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables
connected the UPS to avoid battery drain.
2. The UPS should be stored in a cool dry location.
3. Make sure the battery is fully charged before the UPS is stored.
4. For extended storage in moderate climates, the battery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat
it every 2 months in high temperature locations.
TROUBLE SHOOTING
Problem
Possible Cause
Solution
The UPS does
not perform
expected
runtime.
Batteries are not fully
charged.
Recharge the battery by leaving the UPS
plugged in.
Battery is slightly worn out.
Contact CyberPower Systems at
service@cyberpower-eu.com
The UPS will not
turn on.
The unit is not connected to
an AC outlet.
The unit must be connected to a
220-240V 50/60Hz outlet.
The battery is worn out.
Contact CyberPower Systems at
service@cyberpower-eu.com
Mechanical problem.
Contact CyberPower Systems at
service@cyberpower-eu.com
Outlets do not
provide power to
equipment
Circuit breaker is tripped
due to overload
Turn the UPS off and unplug at least one
piece connected equipment. Unplug the
power cord of the UPS then press the
circuit breaker knob.
Batteries are discharged
Allow the unit to recharge for at least 4
hours.
Unit has been damaged by
a surge or spike.
Contact CyberPower Systems at
service@cyberpower-eu.com
PowerPanel®
Personal Edition
is inactive (all
icons are gray).
The serial/USB cable is not
connected.
Connect the serial/USB cable to the UPS
unit and an open serial port on the back
of the computer. You must use the cable
that came with the unit.
The serial/USB cable is
connected to the wrong
port.
Try another serial/USB port of your
computer.
The unit is not providing
battery power.
Shutdown your computer and turn the
UPS off. Wait 10 seconds and turn the
UPS back on. This should reset the unit.
The serial cable is not the
cable that was provided with
the unit.
You must use the cable included with the
unit for the software.
TECHNICAL SPECIFICATIONS
Model
Value 600ELCD
Value 800ELCD
Value 1000ELCD
Capacity (VA)
600VA
800VA
1000VA
Capacity (Watts)
360W
480W
550W
Input
Frequency Range
47~63Hz(Auto Sensing)
Output
On Battery Output
Voltage
Simulated Sine Wave at 230Vac +/-10%
On Battery Output
Frequency
50/60 Hz
Overload Protection
On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Total # of UPS
Receptacles
(2) Shuko
Maximum Dimensions
32cm(L)*10cm(W)*14cm(H)
Weight
5.2 kg
5.8 kg
6.1 kg
Battery
Sealed Maintenance
Free Lead Acid Battery
12V/7AH
12V / 9AH
12V / 9AH
Typical Recharge Time
8 Hours
Warning Diagnostics
Indicators
Power On, UPS Status Display, Capacity Display, Digital Value
Display
Audible Alarms
On Battery, Low Battery, Overload, Fault
Environmental
Operating Temperature
+32F to 104F ( 0C to 40C )
Operating Relative
Humidity
0 to 95% NON-CONDENSING
Communication
PowerPanel®
Personal Edition
Software
Windows 98/ME/2000/NT/XP/Vista/7
Management
Auto-Charger
Yes
Auto-Restart
Yes
USB
Yes
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
Select SW
Press
UPS Status Display
Capacity Display
Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Time
%
of Load
%
of Batt.
Initial
V
X
--
X
V
X
V
1st
V
X
--
X
V
X
V
2nd
V
X
--
X
V
X
V
3rd
V
X
--
X
X
V
V
4th
V
X
--
X
V
X
V
5th(Return)
V
X
--
X
V
X
V
Press >3sec
(Sound Disable)
V
X
V
X
--
--
--
--
--
--
--
Press >3sec
again
(Sound Enable)
V
X
X
X
--
--
--
--
--
--
--
(Overload)
V
X
--
V
--
--
--
--
--
--
--
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Battery mode
Select SW
Press
UPS Status Display
Capacity Display
Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Time
%
of Load
%
of Batt.
Initial
X
V
--
X
X
V
V
1st
X
V
--
X
X
V
V
2nd
X
V
--
X
V
X
V
3rd
X
V
--
X
X
V
V
4th
X
V
--
X
X
V
V
5th(Return)
X
V
--
X
X
V
V
Press >3sec
(Sound Disable)
X
V
V
X
--
--
--
--
--
--
--
Press >3sec
again
(Sound Enable)
X
V
X
X
--
--
--
--
--
--
--
(Overload)
X
V
--
V
--
--
--
--
--
--
--
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Visit www.cpsww.com for more product information and the nearest CyberPower local contact for your
region.
Entire contents copyright © 2011 CyberPower Systems, Inc All rights reserved. Reproduction
in whole or in part without permission is prohibited.

This manual suits for next models

2

Other CyberPower UPS manuals

CyberPower OR1000LCDRM1U User manual

CyberPower

CyberPower OR1000LCDRM1U User manual

CyberPower Sinewave Series User manual

CyberPower

CyberPower Sinewave Series User manual

CyberPower PFC SINEWAVE UPS Series User manual

CyberPower

CyberPower PFC SINEWAVE UPS Series User manual

CyberPower UT650EG User manual

CyberPower

CyberPower UT650EG User manual

CyberPower OL6KRTMB User manual

CyberPower

CyberPower OL6KRTMB User manual

CyberPower UT400EG User manual

CyberPower

CyberPower UT400EG User manual

CyberPower M550L User manual

CyberPower

CyberPower M550L User manual

CyberPower CP825AVRLCD-G Series User manual

CyberPower

CyberPower CP825AVRLCD-G Series User manual

CyberPower CPS320SL User manual

CyberPower

CyberPower CPS320SL User manual

CyberPower Value1200ELCD User manual

CyberPower

CyberPower Value1200ELCD User manual

CyberPower PR3000LCDRT2U User manual

CyberPower

CyberPower PR3000LCDRT2U User manual

CyberPower UT1500EG User manual

CyberPower

CyberPower UT1500EG User manual

CyberPower PR5000ELCDRTXL5U User manual

CyberPower

CyberPower PR5000ELCDRTXL5U User manual

CyberPower CyberShield K01-DC48V2A User manual

CyberPower

CyberPower CyberShield K01-DC48V2A User manual

CyberPower UT650EG User manual

CyberPower

CyberPower UT650EG User manual

CyberPower PR1000LCDRT2U User manual

CyberPower

CyberPower PR1000LCDRT2U User manual

CyberPower OfficePower 1500AVR-H0 User manual

CyberPower

CyberPower OfficePower 1500AVR-H0 User manual

CyberPower CSN75A12V3-G User manual

CyberPower

CyberPower CSN75A12V3-G User manual

CyberPower SE450G1 User manual

CyberPower

CyberPower SE450G1 User manual

CyberPower PR750LCDRTXL2U User manual

CyberPower

CyberPower PR750LCDRTXL2U User manual

CyberPower BU600E Manual

CyberPower

CyberPower BU600E Manual

CyberPower Professional Rack Mount UPS 2200VA User manual

CyberPower

CyberPower Professional Rack Mount UPS 2200VA User manual

CyberPower DL450ELCD User manual

CyberPower

CyberPower DL450ELCD User manual

CyberPower BU600E-AS User manual

CyberPower

CyberPower BU600E-AS User manual

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

LEGRAND keor 310081 quick start guide

LEGRAND

LEGRAND keor 310081 quick start guide

Eaton Powerware 9125 installation guide

Eaton

Eaton Powerware 9125 installation guide

ABB Conceptpower DPA 500 operating manual

ABB

ABB Conceptpower DPA 500 operating manual

ZincFive BC Series installation instructions

ZincFive

ZincFive BC Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.