manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. CyberPower
  6. •
  7. UPS
  8. •
  9. CyberPower CPS1200EILCD User manual

CyberPower CPS1200EILCD User manual

This manual suits for next models

1

Other CyberPower UPS manuals

CyberPower UR500 User manual

CyberPower

CyberPower UR500 User manual

CyberPower CP900EPFCLCD User manual

CyberPower

CyberPower CP900EPFCLCD User manual

CyberPower SL750U-FC User manual

CyberPower

CyberPower SL750U-FC User manual

CyberPower PowerPanel Business Edition User manual

CyberPower

CyberPower PowerPanel Business Edition User manual

CyberPower OR1500LCDRTXL2U User manual

CyberPower

CyberPower OR1500LCDRTXL2U User manual

CyberPower CP585LCD User manual

CyberPower

CyberPower CP585LCD User manual

CyberPower CP1000AVRL User manual

CyberPower

CyberPower CP1000AVRL User manual

CyberPower Sinewave Series User manual

CyberPower

CyberPower Sinewave Series User manual

CyberPower OP1500AVR-T4 User manual

CyberPower

CyberPower OP1500AVR-T4 User manual

CyberPower UPS BR850ELCD User manual

CyberPower

CyberPower UPS BR850ELCD User manual

CyberPower RMCARD400 User manual

CyberPower

CyberPower RMCARD400 User manual

CyberPower UT850E-FR/UPS User manual

CyberPower

CyberPower UT850E-FR/UPS User manual

CyberPower 649532010004 User manual

CyberPower

CyberPower 649532010004 User manual

CyberPower CPS1200EILCD User manual

CyberPower

CyberPower CPS1200EILCD User manual

CyberPower Value1200ELCD User manual

CyberPower

CyberPower Value1200ELCD User manual

CyberPower BR650ELCD-UK User manual

CyberPower

CyberPower BR650ELCD-UK User manual

CyberPower Value800EI User manual

CyberPower

CyberPower Value800EI User manual

CyberPower UT400EG User manual

CyberPower

CyberPower UT400EG User manual

CyberPower PR1500 User manual

CyberPower

CyberPower PR1500 User manual

CyberPower CPS525SL User manual

CyberPower

CyberPower CPS525SL User manual

CyberPower OLS2000EC/XL User manual

CyberPower

CyberPower OLS2000EC/XL User manual

CyberPower UT1500 User manual

CyberPower

CyberPower UT1500 User manual

CyberPower Office Tower Series UPS 1000 User manual

CyberPower

CyberPower Office Tower Series UPS 1000 User manual

CyberPower PR5000ELCDRTXL5U User manual

CyberPower

CyberPower PR5000ELCDRTXL5U User manual

Popular UPS manuals by other brands

AEG Protect 3.M 2.0 manual

AEG

AEG Protect 3.M 2.0 manual

Alpha Novus FXM 650 Installation and operation manual

Alpha

Alpha Novus FXM 650 Installation and operation manual

Pylontech Victron & Pylontech US5000 manual

Pylontech

Pylontech Victron & Pylontech US5000 manual

BEL LDX-U20 user manual

BEL

BEL LDX-U20 user manual

Mustek PowerMust 530(B) Plus Startup manual

Mustek

Mustek PowerMust 530(B) Plus Startup manual

Emerson Liebert NXL series Operation and maintenance manual

Emerson

Emerson Liebert NXL series Operation and maintenance manual

MAKELSAN BOXER SERIES user manual

MAKELSAN

MAKELSAN BOXER SERIES user manual

Block PC-0524-400-0 manual

Block

Block PC-0524-400-0 manual

Eaton 3S Advanced user's guide

Eaton

Eaton 3S Advanced user's guide

Best Power 610 quick start guide

Best Power

Best Power 610 quick start guide

Best Power Unity/I UT3K user manual

Best Power

Best Power Unity/I UT3K user manual

Mustek PowerMust 400 Offline user manual

Mustek

Mustek PowerMust 400 Offline user manual

Xantrex Trace 512 UR-UPS owner's manual

Xantrex

Xantrex Trace 512 UR-UPS owner's manual

Forza SL-1501UL user manual

Forza

Forza SL-1501UL user manual

LEGRAND keor 310081 quick start guide

LEGRAND

LEGRAND keor 310081 quick start guide

Eaton Powerware 9125 installation guide

Eaton

Eaton Powerware 9125 installation guide

ABB Conceptpower DPA 500 operating manual

ABB

ABB Conceptpower DPA 500 operating manual

ZincFive BC Series installation instructions

ZincFive

ZincFive BC Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CPS1200EILCD/CPS2200EILCD
User’s Manual
IMPORTANT SAFETY INFORMATION
(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack,
install, or operate the inverter.
Insure the wall outlet and inverter are located near the equipment being attached for proper accessibility.
To reduce risk of damage and injury, please use batteries with good quality.
Provide adequate ventilation for the battery compartment. The battery enclosure should be designed to
prevent accumulation and concentration of hydrogen gas at the top of the compartment.
DO NOT expose the inverter to rain, snow or liquids of any type. The inverter is designed for indoor use
only.
DO NOT obstruct the ventilation openings.
DO NOT connect neutral of the power distribution box on the wall to:
(a) The OUTPUT neutral of inverter.
or (b) The INPUT neutral of equipment.
Otherwise the reversed polarity will damage the inverter and the connected equipment.
CAUTION! Risk of electric shock, do not remove cover. No user serviceable parts inside.
The battery can energize hazardous live parts inside even when the AC input power is disconnected.
To avoid electrical shock, turn off the inverter and unplug it from theAC power source before servicing
the battery. Servicing the battery can only be performed by trained personnel.
INSTALLING YOUR HOME UPS SYSTEM
UNPACKING
Inspect the unit upon receipt. The box should contain the following:
Unit1; Power Cord1; User Manual1
HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT
1. Insure that the equipment plugged into the AC outlet does not exceed the inverter unit’s rated
capacity (1200VA/720W for CPS1200EILCD; 2200VA/1320W for CPS2200EILCD). If rated unit
capacities are exceeded, an overload condition may occur and cause the HOME UPS unit to shut
down or the circuit breaker trip.
2. If the power requirements of your equipment are listed in units other than Volt-Amps (VA), convert
Watts (W) or Amps (A) into VA by doing the calculations below. Note: The below equation only
calculates the maximum amount of VA that the equipment can use, not what is typically used by the
equipment at any one time. Users should expect usage requirements to be approximately 60% of
below value.
TO ESTIMATE POWER REQUIREMENTS
1. 220 V x Amps (A) = VA
2. Add the totals up for all pieces of equipment and multiply this total by 0.6 to calculate actual
requirements. There are many factors that can affect the amount of power that your computer system
will require. The total load that you will be placing on the battery-powered outlets should not exceed
80% of the unit’s capacity.
HARDWARE INSTALLATION GUIDE
Before installation, pleaseread and understand the following instructions:
1. Placement
The inverter must be installed in a protected environment away from heat- emitting appliances such
as a radiator or heat register. Do not install this product where excessive moisture is present.
2. Ventilation
The location should provide adequate air flow around the inverter with 10 CM minimum clearance
on all sides for proper ventilation.
3. Connect the Battery
Connect the external battery with the DC cables
from the back of the inverter. Follow battery
polarity guide located near battery cables as
below.
“+”Red cable for battery positive polarity;
“-”Black cable for battery negative polarity.
4. Connect to AC and Charge the Battery
Connect the inverter to a wall outlet. Avoid using extension cords and adapter plugs. Charging the
battery for at least 8 hours is recommended to insure that the battery is fully charged. To recharge
the battery, simply leave the unit plugged into a wall outlet. To maintain optimal battery charge,
leave the inverter plugged into anAC outlet at all times.
This unit can be charged even when it is not turned on.
5. Connect the Load
Connect the equipment to the inverter outlet. Please make sure that the total loads of your
equipments are less than the maximum total power load of the inverter.
BASIC OPERATION
FRONT PANEL DESCRIPTION
1. LCD Module Display.
High resolution and intelligent LCD display shows all the inverter information with icons and
messages. For more information please check the “Definitions for Illuminated LCD Indicators”
section.
2. Power Switch
Press the power switch to turn the inverter ON or OFF.
3. LCD Function Selected Switch
The switch can be used to select the LCD display contents including input/output voltage and load
percentage, etc.
REAR PANEL DESCRIPTION
1. DC Input Cable (Black)
Connect to battery negative polarity.
2. DC Input Cable (Red)
Connect to battery positive polarity.
3. Input Circuit Breaker
The circuit breaker provides optimal overload protection.
All manuals and user guides at all-guides.com
4. Charger Current Control*
A. Select “20A,10A” setting for default battery application. The charge current is 20A default,
10A respectively for CPS1200EILCD.
B. Select “Default” setting for general application. The charge voltage is 27.4V respectively
for CPS2200EILCD.
C. Select “Customized” setting for special battery condition. The charge voltage is 26.6V,
respectively for CPS2200EILCD.
*Note: Operated by trained professionals ONLY. Incorrect operation will damage the battery.
5. Input Voltage Range Selector
Input voltage range is defined in specification section. Output voltage is the same as input voltage
in AC mode.
A. Select “Narrow”setting for general electrical appliance such as TUBE LIGHT, ENERGY
SAVING LAMP, TV, JUICER & MIXER etc. It is not suitable for high-power motor or inductive
load, such as the fridge of 1KW, the motor of 800W, AIR COOLER(having risk of rebooting)
and so on. In this mode, the HOME UPS operating voltage in AC mode is within 190~ 260Vac
with the same output voltage. The line sensitivity is higher.
B. Select “Wide”setting to save energy. In this mode the operating range of voltage for the
inverter is 100-280Vac. Therefore the output voltage will be the same as the MAINS input
voltage. The unit in this mode has a lower sensitivity with a longer transfer time for switching
from AC mode to battery mode in the event of power failure. You can safely connect and use
home appliances which are not sensitive to transfer time limitations such as florescent tubes,
bulbs, TV etc.
6. AC outlet**
The HOME UPS provides one outlet for connected equipment to insure temporary uninterrupted
operation during a power failure and against surges and spikes.
7. AC Inlet
Connect to utility power through the input power cord.
Functional Test
AC Mode
The HOME UPS delivers power to the load derived from the utility and maintains proper battery charge.
On-Battery Mode
The inverter operates on battery when the utility voltage has fallen outside the limits. Local users are
alerted to this mode of operation by visual and audible indicators. The HOME UPS provides power to
the load from the battery and the output voltage of the inverter are regulated within a narrow range
1. Switch On
Press the power switch then the status LCD will light up.
2. Switch Off
Press again the power switch, the status LCD will go off.
3. Cold Start / Start on Battery:
This HOME UPS can be turned on even when AC is not present.
Press the power switch then the status LCD will light up.
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1. Use dry soft clothes to clean the panel and plastic parts. Do not use any detergent that contains
alcoholic ingredient.
2. Unplug the HOME UPS from power inlet if the inverter will not operate for long period of time.
STORAGE
1. First turn off your inverter and disconnect its power cord from the wall outlet. Disconnect all cables
connected the HOME UPS to avoid battery drain.
2. The HOME UPS should be stored in a cool dry location.
3. Make sure the battery is fully charged before the inverter is stored.
4. For extended storage in moderate climates, the battery should be charged for 12 hours every 3
months by plugging the power cord into the wall receptacle and turning on the main switch. Repeat
it every 2 months in high temperature locations.
TROUBLE SHOOTING
Problem
Possible Causes
Remedy
No LCD display
1. Battery Weak
1. Re-charge battery
2. Battery defective
2. Battery replacement.
3. Power switch is not
pressed
3. Press and hold power
switch.
Mains normal but not
works in AC mode
1. AC Input missing
1. Check AC input
connection.
2. Input protector is effective
2. Reset the input protector.
Alarm buzzer beeps
continuously
Overload
Verify that the load
matches the capability
specified in the specs.
Backup time is shortened
Overload
Remove some non-critical
load.
Battery voltage is too
low.
Charge battery for 8 hours
or more.
If any abnormal situations occur that are not listed above, please contact service personnel.
TECHNICAL SPECIFICATIONS
Model
CPS1200EILCD
CPS2200EILCD
Capacity (VA)
1200VA
2200VA
Capacity (Watts)
720W
1320W
Input
Input Voltage Range
Wide mode: 100VAC-280VAC
Narrow mode: 190VAC-260VAC
Frequency Range
50/60Hz
Output
On Battery Output
Voltage
Simulated Sine Wave at 220Vac +/-10%
On Battery Output
Frequency
50/60Hz
Overload Protection
On Utility: Circuit Breaker, On Battery: Internal Current Limiting
Physical
Total # of HOME UPS
Receptacles
(1) UN
Maximum Dimensions
265mm(L)* 250mm(W)* 90mm(H)
Weight
2.05kg / 4.5Lbs
2.2kg / 4.9Lbs
Battery
Lead Acid Battery
12V
24V
Warning Diagnostics
Indicators
HOME UPS Status Display,
Audible Alarms
Low Battery, Overload, Fault
Environmental
Operating Temperature
+32F to 104F ( 0C to 40C )
Operating Relative
Humidity
0 to 90% NON-CONDENSING
Management
Auto-Charger
Yes
Auto-Restart
Yes
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
Select SW
Press
HOME UPS Status
Display
Capacity Display
Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
%
of Load
Initial
V
X
X
--
X
V
V
1st
V
X
X
--
V
X
V
2nd
V
X
X
--
X
V
V
(Overload)
V
X
X
V
--
--
--
--
--
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Battery mode
Select SW
Press
HOME UPS Status
Display
Capacity Display
Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
%
of Load
Initial
X
V
--
--
X
V
V
1st
X
V
--
--
V
X
V
2nd
X
V
--
--
X
V
V
Press >3sec
(Sound Disable)
X
V
V
--
--
--
--
--
--
Press >3sec
again
(Sound Enable)
X
V
X
--
--
--
--
--
--
(Overload)
X
V
--
V
--
--
--
--
--
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Off charging mode (Auto bypass)
Select SW
Press
HOME UPS Status
Display
Capacity Display
Digital Value Display
Load
Cap.
Battery
Cap.
Input
Voltage
Output
Voltage
%
of Load
Initial
V
X
X
X
X
X
X
X
X
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Visit www.cyberpower.com for more product information and the nearest CyberPower local contact for
your region.
Entire contents copyright © 2017 CyberPower Systems, Inc All rights reserved. Reproduction
in whole or in part without permission is prohibited.
All manuals and user guides at all-guides.com