Grounding the Switch
This section describes how to connect the switch
to the ground. You must complete this procedure
before powering on the switch.
Required Tools and Equipment:
• One M4 x 6 mm (metric) pan-head screw
(included in the accessory kit).
• Grounding cable (not included in the accessory
kit): The grounding cable should be sized
according to local and national installation
requirements. Depending on the power supply
and system, a 12 to 6 AWG copper conductor is
required for installation. Commercially available
6 AWG wire is recommended. The length of the
cable depends on the proximity of the switch to
proper grounding facilities.
• A screwdriver (not included in the accessory kit).
You can connect the switch to a protective ground
by following the steps below:
1. Verify if the system power is o.
2. Use the grounding cable to place the #8 terminal
lug ring (not included in the accessory kit) on top
of the ground-screw opening.
3. Insert the grounding screw into the ground
screw opening.
4. Using a screwdriver, tighten the grounding screw
to secure the grounding cable to the switch.
5. Attach the terminal lug ring at the other end
of the grounding cable to an appropriate
grounding stud or bolt on the rack where the
switch is installed.
6. Verify that the ground connections on the switch
and the rack are securely attached.
DIP Switches
The DIP switches on the front panel allow easy
conguration of the advanced features of the
DSS-100E-18P
DIP
Switch Function Controlled Default
Standard
Switch all ports can communicate with each
other port and work as a common Unmanaged
Switch. *1 to 16 port supports Power over Ethernet
and transmit data at 10/100 Mbps.** 1 to 8 port
supports port priority to optimize port cache.
On
Isolate
1 to 16 port can’t communicate with
each other, but each of them can
communicate with port 17 and 18.
O
Extend
The data rate of 9 to 16 port is limited to 10Mbps,
whereas the maximum transmission distance
of the port is increased to 250 meters.
O
Table 4
Hardware Installation
Before You Begin
Observe the following precautions to help prevent
shutdowns, equipment failures, and personal injury:
• Install the DSS-100E-18P in a cool and dry
place. Refer to the technical specications in
the user manual for the acceptable operating
temperature and humidity ranges.
• Install the switch in a site free from strong
electromagnetic sources, vibration, dust, and
direct sunlight.
• Leave at least 10 cm of space to the left and right-
hand side of the switch for ventilation.
• Visually inspect the power connector and make
sure that it is fully secured to the power cord.
• Do not stack any devices on top of the switch.