Dacor 65089-D User manual

IMPORTANT
1. Before beginning installation, please thoroughly read and become familiar with these instructions.
2. Installation and service must be completed by a qualified installer or service agency.
3. Installer: Please leave these Installation Instructions with the owner.
4. Owner: Please keep these instructions for local electrical inspectorʼs use and for future reference.
5. Read the accompanying Use & Care Manual prior to operating this appliance.
TABLE OF STEPS
STEP 1 Verifying package contents Page 2
STEP 2 Gas supply requirements Page 2
STEP 3 Electrical power supply requirements Page 2
STEP 4 Gas and electrical rough-in locations Page 2-3
STEP 5 Cabinet and countertop preparation Page 3-4
STEP 6 Overall dimensions Page 5
STEP 7 Installing the anti-tip bracket Page 5
STEP 8 Gas regulator and electrical conduit location Page 6
STEP 9 Removal and installation of backguards Page 6
STEP 10 Removing the oven door Page 7
STEP 11 Electrical connection Page 7-8
STEP 12 Gas connection Page 8
STEP 13 Installing the range Page 8
STEP 14 Installing the burner components Page 9
STEP 15 Re-installing the oven door Page 9
STEP 16 Verifying proper operation Page 9
Part No. 65089-D Rev. 123003
TESTED IN ACCORDANCE WITH THE LATEST EDITION OF ANSI Z21.1 STANDARD FOR
HOUSEHOLD GAS COOKING APPLIANCES.
NOTES:
Contain helpful hints and tips to facilitate the installation.
CONVENTIONS USED IN THESE INSTRUCTIONS
IMPORTANT:
Must be followed carefully to avoid damage.
WARNINGS:
Must be followed carefully to avoid personal injury.
SAVE AND READ THESE INSTRUCTIONS
Installation Instructions
Epicure™ Ranges

INSIDE FRONT COVER
THIS PAGE IS BLANK INTENSIONALLY
Page 1

INSIDE FRONT COVER
THIS PAGE IS BLANK INTENSIONALLY
Page 1
WARNINGS:
1. Read all instructions before using the appliance.
2. If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or death.
3. Improper installation, adjustment, alteration, service, or maintenance can cause personal injury
or property damage. Refer to these instructions and the accompanying Use & Care Manual. For
assistance or additional information, consult a qualified installer, service agency, manufacturer
(dealer), or the gas supplier.
4. What to do if you smell gas:
• Do not try to light any appliance.
• Do not touch any electrical switch, do not use any phone in your building.
• Immediately call the gas supplier from a neighborʼs phone.
• Follow the gas supplierʼs instructions.
• If you cannot reach your gas supplier, call the fire department.
5. For your safety:
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
• Do not obstruct the flow of combustion and ventilation air to the unit.
• Keep appliance area clear and free from combustible material.
• Do not use or attempt to use this appliance in the event of a power failure.
6. This unit is designed as a cooking appliance. Never use it for warming or heating a room.
7. This appliance must not be used in combination with surface (countertop) ventilation systems.
The use of an overhead hood is recommended for ventilation.
8. This appliance must be installed with the gas pressure regulator supplied with it.
9. Disconnect the electrical supply before installing or servicing the appliance.
10. This appliance must be grounded. Connect only to a properly grounded electrical supply. Refer
to “Electrical Requirements”.
11. Install or locate this appliance only in accordance with these installation instructions.
12. Use this appliance only for its intended use as described in this manual. Do not use corrosive
chemicals or vapors in this appliance. This type of appliance is not designed for industrial or
laboratory use.
13. As with any appliance, close supervision is necessary when used by children.
14. Do not operate this appliance if it has a damaged electrical cord, plug, conduit or wires, if it is not
working properly, or if it has been damaged or dropped.
15. Installation of this appliance must be performed by a qualified installer, service agency or the
gas supplier.
16. This appliance should be serviced only by qualified service personnel. Contact the nearest
DACOR Authorized Servicer at (800) 772-7778, or at www.dacor.com for examination, repair or
adjustment.
Some products, such as whole eggs, and sealed containers, such as closed glass jars, may
explode and should not be heated on this cooktop.
Important Safety Instructions

Page 2
Page 3
STEP 1
Verifying the Package Contents
Verify that all required components have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not
install a damaged or incomplete appliance.
• Use & Care Manual • Ignitor Cleaning Kit • Broiler Pan/Grill
• Anti-tip Bracket (selected models) • Grate/Burner Cap Packs • Griddle
• Burner Rings • Wok Ring • Simmerplate
• Spatula • Stainless Steel Cleaner • Pry Stick
STEP 2
Gas Supply Requirements
Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in
accordance with the National Fuel Gas Code ANSI Z223.1. Be certain that the appliance being installed is correct for the gas service being
provided. Refer to the data plate located behind the inlet air cooling grill, and/or to Table 1 below, for gas supply requirements. Open the oven
door and remove the inlet air cooling grill for access to the data plate.
Table 1: Gas and Electrical Supply Requirements
STEP 3
Electrical Power Supply Requirements
It is the ownerʼs responsibility to ensure that the electrical connection of this appliance is performed by a qualified electrician. The electrical
installation, including minimum supply wire size and grounding, must be in accordance with the National Electric code ANSI/NFPA 70-1993*
(or latest revision) and local codes and ordinances.
*A copy of this standard may be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency, and amperage must be supplied to the appliance from a separate, grounded, circuit that is protected by a
properly sized circuit breaker or time delay fuse. Refer to the data plate, and/or to Table 1 above, for gas supply requirements.
NOTE:
The shaded areas shown in the illustrations, denote the location of the gas stub and the electrical
junction box/receptacle. These are suggested locations. For replacement purposes, the location
of the existing utilities may be utilized provided that they do not interfere with the sides or rear
of the range. If installing the gas valve behind the range, verify that local building codes will
permit this.
NOTES:
1. The power supply must be properly polarized. Reverse polarity will result in continuous sparking
of the electrodes, even after flame ignition.
2. If there is any doubt as to whether the power supply is properly polarized or grounded, have it
checked by a qualified electrician.
WARNING:
If the gas or electric service provided does not meet the product specifications, do not proceed
with the installation. Call the selling dealer, the gas supplier, or a licensed electrician.
STEP 4
Gas and Electrical Rough-In Locations
WARNING:
This appliance must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts.
DACOR
Model number
EGR30
EGR30LP
ERD30
ERD30LP
ERD36
ERD36LP
ERDE36
ERDE36LP
ERD48
ERD48LP
ERDE48
ERDE48LP
ERD60
ERD60LP
Electrical circuit
required
120VAC, 60Hz, 15A
120/240VAC, 60 HZ, 30A
120/240VAC, 60 HZ, 40A
120/240VAC, 60 HZ, 50A
Total
connected load
0.75kW (6A)
4.2kW (22A)
4.7kW (24A)
7.7kW (34A)
10.0kW (46A)
10.8kW (48A)
8.4kW (43A)
Gas type
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Natural
Liquid Propane
Manifold pressure
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
5 inch water column
10 inch water column
Min. gas supply
pressure
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column
6 inch water column
11 inch water column

Page 2
Page 3
STEP 4 (Continued)
Gas and Electrical Rough-In Locations
A manual shut valve must be installed in the gas piping, external to the appliance, for the purpose of turning on or shutting off gas to the
appliance. Plan the location of the range and the gas supply to allow access to the valve when the unit is installed. Access to the remote circuit
breaker panel/fuse box, with the range in place, must also be allowed for in the installation. Any openings in the wall behind the appliance
and in the floor under the appliance must be sealed.
Both the gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range
when it is installed. In addition, the junction box must be located so the range can be removed for service when the conduit supplied with the
unit is attached to the junction box. Do not lengthen the conduit or wiring provided with the range.
All dimensions shown are based on standard American cabinets 36 inches (914mm) high at the finished countertop by 24 inches (610mm)
deep, with a 25 inch (635mm) overall countertop depth. When installing the range into nonstandard cabinets, minimum clearances shown
in the diagrams must be maintained.
Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may
be caused by doors, windows and HVAC outlets.
STEP 5
Cabinet and Countertop Preparation
NOTE:
1. If cabinet storage space is to be provided directly above the range, the risk of personal injury
may be reduced by installing a ventilating hood that projects horizontally a minimum of 5 inches
beyond the face of the cabinets.
2. The range may be installed flush to the rear wall. We recommend installing a non-combustible
material on the rear wall above the range and up to the vent hood. It is not necessary to install
non-combustible materials behind the range below the countertop height.
3. The minimum distance from the sides of the range above the countertop to combustible side
walls must be at least 10 inches.
A
A
25"
(635mm)
8"
(203mm)
12"
(305mm)
30" (762mm)
Minimum
18" (457mm)
Minumim
10" (254mm) Min.
to combustible side
walls above the range
(both sides)
Top of
finished
counter
Vertical
non-combustible
surface
Hood
13"
(330mm)
Maximum
B
ERD36 & ERD48
NOTE:
Install either the 3”, 9” or 24” Backguard
on the Range prior to installing the Range
into the cabinet cutout.
Utilities may be located:
In the lower left corner of the adjacent right
cabinet. (Recommended)
Contact your local building department to verify
compliance with local code interpretation.
Model number
ERD30/EGR30
ERD36
ERDE36
ERD48
ERDE48
ERD60
“A”
36” (914mm)
Recommended
30” (762mm) Minimum
42” (1067mm)
Recommended
36” (914mm) Minimum
54” (1372mm)
Recommended
48” (1219mm) Minimum
66” (1676mm)
Recommended
60” (1524mm) Minimum
“B”
30 1/16”
(764mm)
36 1/16”
(203mm)
48 1/8”
(1222mm)
60 1/8”
(1527mm)

Page 4
Page 5
STEP 5 (Continued)
Cabinet and Countertop Preparation
27 13/16"
(706mm)
29 1/4" (743mm)13/32" (10mm)
30 1/16" (764mm)
Countertop overhangs cabinet 6" (152mm) Min.
to combustible side
walls above the range
(both sides)
27 7/8" (708mm)
Adjust for backsplash
over 3/4" thick
from 13/16" to 3 13/16"
(21 - 97mm)
Backsplash
thicker than
3/4" (19mm)
1/4" (6mm)
Min. flat ledge
Vertical
non-combustible
surface rear wall
2 13/16"
(71mm)
27 13/16"
(706mm)
29 1/4" (743mm)13/32" (10mm)
30 1/16" (764mm)
Countertop overhangs cabinet 6" (152mm) Min.
to combustible side
walls above the range
(both sides)
Vertical
non-combustible
surface rear wall
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
27 7/8" (708mm)
2 13/16"
(71mm)
ERV30 with ERD30 Slide-In,
Self-Rimming Installation using 3” Side Panels
(Model No. AESP03), Backguard Removed.
Top View
29 1/4" (743mm)13/32"
(10mm)
30 1/16" (764mm)
3/4" (19mm)
Max. backsplash
1/4" (6mm)
Min. flat ledge
13/16" (21mm)
23 3/16"
(589mm)
20 3/16"
(513mm)
29 1/4" (743mm) 13/32"
(10mm)
30 1/16" (764mm)
Vertical
non-combustible
surface
Vertical
non-combustible
surface
Rear wall Rear wall
Variable
13/16" - 3 13/16"
(21 - 97mm)
ERD/EGR30 Slide-In, Self-Rimming Installation with
Side Panels and Backguard Removed
Top View
ERD/EGR30 Slide-In, Self-Rimming Installation
using 3” Side Panels (Model No. AESP03),
Backguard Removed.
Top View
ERV30 with ERD30 Slide-In,
Self-Rimming Installation with Side Panels and Backguard Removed
Top View

Page 4
Page 5
STEP 6
Overall Dimensions
27" (686mm)
26" (660mm)
28 1/2" (724mm)
37”
(940mm)
to
35 3/4"
(908mm)
Finished Side Panel
24 3/8" (619mm) Rear of Control Panel/Oven Door
Face of Control Panel/Oven Door
Front Edge of Bullnose
Handle
6” (152mm) Backguard
When Backguard and
Side Panels are removed,
the overall depth decreases
by 1" (25mm)
Accessory 3” (76mm) Side Panels
(Dacor Model No. AESP03)
1 9/16"
(40mm)
29 1/8" (740mm)
28 1/8" (714mm)
30 3/8" (772mm)
1 9/16"
(40mm)
37”
(940mm)
to
35 3/4"
(908mm)
Finished Side
Panel
26 1/2" (673mm) Rear of Control Panel/Oven Door
Face of Control Panel/Oven Door
Front Edge of Bullnose
Handle
9"
(229mm)
3"
(79mm)
15 1/4"
(387mm)
24"(610mm)
Backguard
9" (229mm)
Backguard
3" (76mm)
Backguard
19"
(483mm)
ERD/EGR30, ERD60 Overall Dimensions
Side View
(ERD30 shown)
ERD36, ERDE36, ERD48 & ERDE48 Overall Dimensions
Side View
NOTE:
For ERD all front-to-back depth
dimensions are reduced by 1”
(25mm) when Backguard and full
side panels are removed.
NOTE:
For Backguard Installation (36” and 48” models)
see page 6. Always install backguard before
installation of the range.
STEP 7
Installing the Anti-Tip Bracket (30” & 36” Models Only)
Back wall
7 1/2"
(191mm)
4 13/16" (122mm)
24" (610mm)
36 1/16" (916mm)
18 1/32"
(458mm)
All dimensions are from
cabinet only
(not countertop)
WARNING:
The 30” and 36” ranges require an anti-tip device. Before installing the range, you must locate and
secure the anti-tip bracket to the floor.
Installation of ERD30 Anti-Tip Bracket
Top View
Rear Wall
8 3/8”
(213mm)
24"
(610mm)
30 1/16" (764mm)
All Dimensions are from
Cabinet Only
(Not Countertop)
Floor
2 3/16”
(56mm)
3 7/8" (98mm)
1 1/2" (38mm)
Left
Rear
Leg
Leveler
5/16 - 18 x 2
or Equivalent
Rear
Location of ERD30 Anti-Tip Leveler
Installation of ERD36 Anti-Tip Bracket
Top View
Right
Rear
Leg Leveler
5/16 - 18 X 2
or Equiv.
Rear
Location of ERD36 Anti-Tip Leveler

Page 6
Page 7
STEP 8
Gas Regulator and Electrical Conduit Location
Factory installed
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
3/4" regulator
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Factory installed
3/4" regulator
(1/2" supply ok)
Power cord
Gas Regulator and Electrical Conduit Location
Rear View
STEP 9
Installing the 36” and 48” Range Backguards
4. Locate and install the flue exhaust extensions at the rear of the range (9" and 24" backguards only). Use the provided hex screws and
tighten securely into the pre-drilled holes.
Remove Screw
Shipping Cover
WARNING:
Be sure that the unit is not connected to gas or power before proceeding.
Your DACOR range was equipped with a shipping cover to protect the internal components prior to installation.
This cover must be removed and replaced by a DACOR backguard for your range to function properly.
1. Unpack the contents of the box and verify parts with the Packing List.
2. Remove the single screw on the top of the shipping cover.
3. Slide the shipping cover off the unit.
5. Remove the backguard from its box.
6. To avoid scratches, place small scraps of thin cardboard on the rear of the side panels where the backguard will make contact. With the
assistance of at least one other person, carefully lift the backguard over the exhaust flues and place down on to the range top. Special
attention should be given to the lower flange in front of the backguard, which must fit between the stainless steel side panels.
7. Fasten the provided screws through the rear flange.
Backguard
Flue with Extension
(9" and 24" only)
Backguard
Flue with Extension
(9" and 24" only)
Shipping Cover Shipping Cover Removal
(36” range shown)
ERD with 9” Flue Extension
(9" flue extension shown)
ERD48 with 9” Flue Extension
(9" flue extension shown)
ERD Backguard Installation ERD48 Backguard Installation
8. Connect the gas line to the regulator. Reposition and attach the access panel or the back cover if the entire back cover was removed.
9. You are now ready to continue with the range installation.
NOTE:
For 24” Backguards, fasten the provided screws through the holes in the back panel of the
Backguard.

Page 6
Page 7
STEP 10
Removing the Oven Door
To remove door,
rotate catch up.
Lift door up to 30˚ angle,
then pull door away
from the range oven section.
30˚
Hinge Catch
Removing the Oven Door
Open the door to its fully opened position. Rotate the catch over the retaining arm on each hinge. Lift the oven door to about a 30 degree angle
from the horizontal position. Pull the door away from the oven while continuing to lift.
WARNINGS:
1. Do not attempt to disengage the hinge catches with the door removed from the oven. The hinge
springs could release causing personal injury.
2. Do not lift or carry the oven door by the door handle.
Grounding Instructions (ERD Models Only)
This appliance must be electrically grounded.
With the range positioned directly in front of the cabinet cutout, feed the appliance conduit to the electrical
junction box. Then, depending upon local codes, utilize one of the following techniques to connect the appliance to the electrical power
supply:
WARNINGS:
1. ERD models must be connected to a grounded, metallic, permanent wiring system. Alternatively,
a grounding conductor should be connected to the grounding terminal or lead on the appliance.
2. ERG models must be connected to a grounded receptacle. Failure to do so may result in an
electrical shock hazard.
3. Do not use an extension cord with this appliance. Such use may result in fire, electrical shock,
or other personal injury.
4. Do not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may
result in an electrical shock hazard.
STEP 11
Electrical Connection
A. Connecting to a Four-Wire Electrical System (Refer to Figure 21 below)
1. Separate the green and white appliance wires.
2. Connect the white appliance wire to the neutral (white) supply wire in the junction box.
3. Connect the black appliance wire to the black (L1) power supply wire in the junction box.
4. Connect the red appliance wire to the red (L2) power supply wire in the junction box.
5. Connect the green appliance wire to the green house grounding wire in the junction box.
WARNING:
**Do not connect the green appliance wire to the neutral (white) supply wire unless local building
codes permit.
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Conduit from
appliance
Cable from
power supply
Wire nut
(3 places)
Junction
box
RED
RED
GREEN
WHITE
WHITE
BLACK
BLACK
Connecting the appliance to a
four-wire power supply
**Connecting the appliance to a
three-wire power supply

Page 8
Page 9
STEP 12
Gas Connection
STEP 11 (Continued)
Electrical Connection - ERD Model Ranges Only
B. Connecting the Green Appliance Wire to the Neutral (White) Supply Wire – Where Local Codes Permit
1. Connect the green and white appliance wires to the neutral (white) supply wire in the junction box.
2. Connect the black appliance wire to the black (L1) power supply wire in the junction box.
3. Connect the red appliance wire to the red (L2) power supply wire in the junction box.
C. Connecting the Green Appliance Wire to a Grounded Supply Wire or a Grounded Cold Water Pipe – Where Local Codes Permit.
1. Separate the green and white appliance wires.
2. Connect the white appliance wire to the neutral (white) supply wire in the junction box.
3. Connect the black appliance wire to the black (L1) power supply wire in the junction box.
4. Connect the red appliance wire to the red (L2) power supply wire in the junction box.
5. Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water pipe.
6. If connecting to a grounded cold water pipe, a separate copper grounding wire (No. 10 minimum) must be connected to a grounded cold
water pipe by means of a clamp and then to an external grounding connector screw.
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
Separate No. 10 (minimum)
copper grounding wire
Clamp must be
tight on pipe
No. 4
copper wire
Metal
water pipe
Clamps
Bare metal
Meter
Connecting the appliance ground to a grounded
junction box wire or grounded cold water pipe
WARNINGS:
1. Do not ground the appliance to a gas supply pipe or hot water pipe.
2. Do not turn on power to the appliance until the range is permanently grounded.
3. A grounded cold water pipe must have metal continuity to electrical ground and must not be
interrupted by insulating materials. Any insulating materials must be jumped (as shown in Figure
23 below) with a length of No. 4 copper wire securely clamped to bare metal at both ends.
Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off valve previously installed on the stub out. The gas
valve must be turned off during installation. Connect the flex connector to the pipe fitting at the right rear of the range.
WARNINGS:
1. Do not apply excessive pressure when tightening gas connections and fittings.
2. Do not use teflon tape or plumberʼs putty on gas flex line connections.
3. Turn all cooktop control valves to the “OFF” position. Turn on gas supply and check all lines and
connections for leaks using a soap and water solution. Do not use a flame to check for leaks.
After verifying that there are no gas leaks, turn off the gas supply to the range by turning the
gas shut-off valve to the “OFF” position.
4. For LP installations, the LP gas tank must have its own high pressure regulator. This is in
addition to the pressure regulator provided with the range.
5. The maximum gas supply pressure to the regulator must never exceed 1/2 pound per square
inch.
NOTE:
The gas pressure regulator is pre-set at the factory for the type of gas intended for use with
the appliance. Verify that the appliance is compatible with the type of gas available by checking
the data plate located behind the inlet air cooling grill. Open the oven door and remove the inlet
air cooling grill for access to the data plate. Ranges intended for use with LP gases will have
“LP” as a part of the model number. Consult your dealer if the range is not compatible with
your gas supply.
STEP 13
Installing the Range
Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height, based on
the cabinet and countertop installation. Carefully slide the range into position in the cutout. The rear anti-tip leg should engage the anti-tip
bracket.(30 and 36 inch models only)
When the range is to be installed as a “slide-in, self rimming” (with the range top overhanging the countertop cutout - ERD/ERG30 models
only), measure from the floor to the countertop. Adjust the leveling legs to position the bottom edge of the range top frame approximately 1/8”
above the level of the countertop. This will allow the range to slide over the countertop. Carefully slide the range into position in the cutout. The
rear anti-tip leg should engage the anti-tip bracket. To lower the range onto the countertop, turn the leveling legs counterclockwise. Lower the
range until the bottom of the range top just contacts the countertop. Do not allow the full weight of the range to hang on the counter.

Page 8
Page 9
STEP 14
Installing the Burner Components
Remove the brass burner rings, porcelain burner caps, and porcelain gates from their shipping packages. Place each burner ring onto its
corresponding burner base, being certain that the five alignment tabs slide into the matching notches in the base. Set each porcelain burner
cap on top of its corresponding burner ring. Place oven exhaust cover over the opening in the top frame. Place each grate onto the top frame,
being certain that the rubber feet are positioned in the locating dimples.
NOTE:
Prior to operating the cooktop or oven sections of the range, please read the accompanying Use
and Care Manual carefully. Important safety, service and warranty information is contained within
this manual.
WARNING:
Never attempt to operate the cooktop section of the range with any of the burner rings, burner
caps or grates removed.
STEP 15
Re-installing the Oven Door(s)
Grasp the oven door on opposite sides and lift it until the door hinges are aligned with the openings in the oven frame. Holding the door at
about a 30˚ angle from the horizontal, slide the hinges into the openings until the bottom hinge arms drop fully into the hinge receptacles.
Lower the door to the fully opened position, and then rotate the two hinge catches toward the oven. Open and close the door completely
to ensure that it is properly installed.
Peel off the protective layer of plastic that covers the door panel.
STEP 16
Verifying Proper Operation
Before beginning the test procedure, ensure that all cooktop control valves are in the “OFF” position, and all burner rings, burner caps, and
grates are properly positioned on the top frame. Turn on the gas supply at the shut-off valve.
Turn on the power supply to the range. Set the time of day by pressing the “CLOCK” key and then pressing either of the “TIME•TEMP”
keys to advance or reduce the time in the display in the desired setting. Press the “BAKE” key. Select a temperature of 350˚F by pressing
the “TIME•TEMP” “+” key. The display should show “BAKE ON”. Press the “CANCEL•SECURE” key to stop the oven heating process. Test
each top burner separately by pressing and turning one control knob at a time counterclockwise to the “HIGH” position. All ignitors will spark
continuously, but only the burner with gas flowing to it will ignite. (It will take approximately 4 seconds for ignition to occur, at which time
the ignitors will stop sparking. If ignition does not occur within 4 seconds, turn off the knob, wait for at least 2 minutes to allow any gas to
dissipate, then repeat this ignition test.) The control knob can then be rotated counterclockwise from “HIGH” to “LOW” to adjust the flame height
progressively. Repeat the ignition test for all burners. When installed properly, the flame will be steady and quiet. It will also have a sharp, blue
inner cone that will vary in length proportional to the burner size.
NOTES:
If either the oven or cooktop does not operate properly, follow these troubleshooting steps:
1. Verify that power and gas are supplied to the range.
2. Check the electrical connections and gas supply to ensure that the installation has been
completed correctly.
3. Repeat the above bake test or burner ignition test.
4. If the appliance still does not work, contact an authorized DACOR service company at
(800) 772-7778. Do not attempt to repair the appliance yourself. DACOR is not responsible for
service required to correct a faulty installation.
WARNINGS:
1. The range and shut-off valve must be disconnected from the gas supply piping during any
pressure testing exceeding 1/2 psi (3.5kPa).
2. The range must be isolated from the gas supply piping by closing the shut-off valve during any
pressure testing at or below 1/2 psi (3.5 kPa).

Page 10
Page 11
NOTES

Page 10
Page 11
NOTES

Page 12
INSIDE BACK COVER
THIS PAGE IS BLANK INTENSIONALLY
NOTES

Page 12
INSIDE BACK COVER