• Indoor Unit • FCAG-A
7
• Split - Sky Air • FCAG-A
12
7 Wiring diagrams
7 - 1 Wiring Diagrams - Single Phase
H05VV-U4G2.5
1
2
3
X2M
BLK
WH
T
RED
1
2
3
TC RC
X35A X20A X70A
X27A K2R
F1U
Z1F
V1R
C105
PS H1P
X36A
A4P A3P
X30A
X81A
X83A
X17A
X33A
X2A
X1
X2
X3
X4
KC
R
KFR
F1U
F2U
KHuR
Y
C
Y2
S1L
R2T R1T
GR
N
Z2C
N=1
R3T
A2P
DS1
EMG.
STB.
X39A
X24A
X2A
OFF ON
OFF ON
DS1
DS2
X1A X1A BS1
H1P
H2P
H3P
H4P
H5P
H6P
P
N
R1T
A5P A6P
A1P
PE
A7P
X1A
X15A X18A X16A NE
Z1C
N=1
BL
K
BLK
GRY
GRY
M1F
M4S M3S M2S M1S
M1P
PNK
WH
T
YLW
ORG
BLU
BL
K
X1M
WHT
BLK
RED
BLU
GRY
PNK
PPL
YLW
GRN
ORG
X25A
MS
MSW
MS
WHT
ORG
BRN
BLU
RED
RED
BLU
WHT
RED
BLK
BLU
YLW
BRN
RED
BLK
BLU
YLW
BRN
RED
BLK
BLU
YLW
BRN
RED
BLK
BLU
YLW
BRN
T2
T1
F2
F1
P2
P1
X2M
3
2
1
X2M
3
2
1
X2M
3
2
1
BLK
BLK
BLK
BLK
BLK
BLK
BLK
X35A
X24A
X23A
X33A X70A
X50A
X39A
A1
P
X2M
X1M
X6A
t°
t°
t°t°
MSW MSW MSW
3'109572
FCAG-A
Outdoor
(note 3)
Indoor
Norm.
OFF ON
Input from outside
Wired remote
control
(note 6)
Sensor kit (optional)
In case of simultaneous
operation system (note 5)
Position of connectors in control box
Remote control
(Note 7)
Adapter for wiring (optional) (note 9)
Terminal for
operation display
Fan operation
Compressor
operation Receiver/display unit (optional)
Central remote
control (note 4)
Indoor unit
A1P Main PCB
C105 Capacitor
F1U Fuse (T, 3.15A, 250V)
DS1 Dip switch on PCB
H1P Flashing lamp (service monitor green)
K2R Magnetic relay (drain pump)
M1P Motor (drain pump)
M1F Motor (indoor fan)
M1S-M4S Motor (swing blade)
R1T Thermistor (air)
R2T, R3T Thermistor (coil)
V1R Diode bridge
X1M Terminal block (remote control)
X2M Terminal block (power supply)
Z1C, Z2C Ferrite core
Z1F 1RLVH¿OWHU
PS Power supply circuit
RC Signal receiver circuit
TC Signal transmission circuit
NE Noiseless earth
Sensor kit
A3P, A4P Sensor kit PCB
Infrared remote control (receiver/display unit)
A5P Receiver PCB
A6P Display PCB
BS1 Push button (on/off)
H1P Pilot lamp (on: red)
H2P Pilot lamp (timer: green)
H3P 3LORWODPS¿OWHUVLJQUHG
H4P Pilot lamp (defrost: orange)
H5P Pilot lamp (element cleaning: red)
H6P Pilot lamp (timer: green)
DS1 Dip switch (main/sub)
DS2 Dip switch (wireless address set)
Adapter for wiring
A7P Adapter PCB
F1U Fuse (5A, 250V)
F2U Fuse (5A, 250V)
KHuR Magnetic relay
KCR Magnetic relay
KFR Magnetic relay
Connectors for optional parts
X1A Connector (power supply for option PCB)
X2A Connector (sensor kit)
X24A Connector (infrared remote control)
X33A Connector (adapter for wiring)
X35A Connector (auto clean panel)
X39A Connector (auto clean panel)
X70A Connector (auto clean panel)
X81A Sensor kit
Wired remote control
R1T Thermistor (air)
Humidity sensor
A2P Sensor PCB
NOTES
1. : terminal block, : connector, ¿HOGZLULQJ
2. In case of simultaneous operation indoor unit system, see the indoor unit wiring only.
3. For details, see wiring diagram attached to the outdoor unit.
4. In case of using central remote control, connect it to the unit in accordance with the attached installation manual.
5. In case of simultaneous operation system, connected quantity of the indoor units varies according to the connected outdoor unit.
6. In case of main/sub changeover, see installation manual attached to the remote control.
7. Shown only in case of protection piping, use H07RN-F in case of no protection.
8. X35A, X39A, X70A are connected when optional accessories are being used (auto clean panel), see wiring diagram of this accessory.
9. Connect power of adapter for wiring to terminal block (X2M) of indoor unit directly.
10.Colors: BLK: Black, RED: Red, BLU: Blue, WHT: White, YLW: Yellow, GRN: Green, BRN: Brown, PPL: Purple, PNK: Pink, ORG: Orange.