manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Daikin
  6. •
  7. Air Conditioner
  8. •
  9. Daikin FXSQ07TAVJU User manual

Daikin FXSQ07TAVJU User manual

SYSTEM Inverter Air Conditioners
OPERATION MANUAL
MODELS
Ceiling-mounted Duct type
FXSQ05TAVJU
FXSQ07TAVJU
FXSQ09TAVJU
FXSQ12TAVJU
FXSQ15TAVJU
FXSQ18TAVJU
FXSQ24TAVJU
FXSQ30TAVJU
FXSQ36TAVJU
FXSQ48TAVJU
FXSQ54TAVJU
English
Français
Español
00_CV_3P184442-12W.indd 1 9/4/2017 13:36:54
VRV-3
Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air
conditioner. It will tell you how to use the unit properly and
help you if any trouble occurs.This manual explains about the
indoor unit only. Use it along with the operation manual for the
outdoor unit. After reading the manual, le it away for future
reference.
Nous vous remercions pour votre acquisition de ce système
de climatisation Daikin.
Lisez attentivement ce manuel avant d’utiliser le climatiseur.
Il vous expliquera comment vous servir correctement de
l’appareil et vous guidera en cas de problème. Ce manuel
ne décrit que l’unité intérieure. Utilisez-le avec le manuel de
l’unité extérieure. Lorspue vous aurez lu le manuel, rangez-le
an de pouvoir vous y référer ultérieurement.
Le agradecemos la compra de este acondicionador de aire
Daikin.
Lea cuidadosamente el manual de funcionamiento antes de
utilizar el acoundicionador de aire. Dicho manual le indicará
cómo utilizar adecudamente la máquina y le ayudará en
caso de avería. Este manual describe sólo la unidad interior.
Utilice conjuntamente con el manual de instrucciones de la
unidad exterior. Después de leer el manual, consérvelo para
consultas futuras.
00_CV_3P184442-12W.indd 2 9/4/2017 13:36:54
i
English
SAFETY CONSIDERATIONS
Read these Safety Considerations for Operations carefully
before installing air conditioning equipment. After completing
the installation, make sure that the unit operates properly
during the startup operation. Instruct the customer on how to
operate and maintain the unit.
Inform customers that they should store this Operation Manual
with the Installation Manual for future reference.
Meanings of DANGER, WARNING, CAUTION, and NOTE
symbols:
DANGER...........Indicates an imminently hazardous
situation which, if not avoided, will result
in death or serious injury.
WARNING.........Indicates a potentially hazardous situa-
tion which, if not avoided, could result in
death or serious injury.
CAUTION..........Indicates a potentially hazardous situa-
tion which, if not avoided, may result in
minor or moderate injury. It may also be
used to alert against unsafe practices.
NOTE ................Indicates situations that may result in
equipment or property-damage acci-
dents only.
DANGER
• Donotinstalltheunitinanareawhereammable
materialsarepresentduetoriskofexplosionresulting
inseriousinjuryordeath.
• Anyabnormalitiesintheoperationoftheaircondition-
erorheatpumpsuchassmokeorrecouldresultin
severeinjuryordeath.Turnoffthepowerandcontact
yourdealerimmediately.
• Refrigerantgasmayproducetoxicgasifitcomesin
contactwithre,suchasfromafan,heater,stove,or
cookingdevice.Exposuretothisgascouldcause
severeinjuryordeath.
• Forrefrigerantleakage,consultyourdealer.
Refrigerantgasisheavierthanairandreplacesoxy-
gen.
Amassiveleakcouldleadtooxygendepletion,espe-
ciallyinbasements,andanasphyxiationhazardcould
occurleadingtoseriousinjuryordeath.
• Ifequipmentutilizingaburnerisusedinthesame
roomastheairconditionerorheatpump,thereisthe
dangerofoxygendeciencywhichcouldleadtoan
asphyxiationhazardresultinginseriousinjuryor
death.Besuretoventilatetheroomsufcientlyto
avoidthishazard.
• Safelydisposeofthepackingmaterials.Packingmate-
rials,suchasnailsandothermetalorwoodenparts,
maycausestabsorotherinjuries.
• Tearapartandthrowawayplasticpackagingbagsso
thatchildrencannotplaywiththem.
Childrenplayingwithplasticbagsfacethedangerof
deathbysuffocation.
WARNING
• Contactyourdealerforrepairandmaintenance.Im-
properrepairandmaintenancemayresultinwater
leakage,electricshock,andre.Onlyuseaccessories
madebyDaikinthatarespecicallydesignedforuse
withtheequipmentandhavetheminstalledbyapro-
fessional.
• Contactyourdealertomoveandreinstalltheaircondi-
tionerorheatpump.Incompleteinstallationmayresult
inwaterleakage,electricshock,andre.
• Neverlettheindoorunitortheremotecontrollerget
wet.Watercancauseanelectricshockorare.
• Neveruseammablespraysuchashairspray,lacquer,
orpaintneartheunit.Flammablespraymaycausea
re.
• Whenafuseblowsout,neverreplaceitwithoneof
incorrectampereratingsordifferentwires.
• Neverinspectorservicetheunitbyyourself.Contacta
qualiedservicepersontoperformthiswork.
• Turnoffallelectricalpowerbeforedoinganymainte-
nancetoavoidtheriskofseriouselectricshock;never
sprinkleorspillwaterorliquidsontheunit.Donot
touchtheswitchwithwetngers.
Touchingaswitchwithwetngerscancauseelectric
shock.
• Donotallowchildrentoplayonoraroundtheunitto
preventinjury.
• Theheatexchangernsaresharpenoughtocut.To
avoidinjurywearglovesorcoverthenswhilework-
ingaroundthem.
• Donotputangerorotherobjectsintotheairinletor
airoutlet.Thefanisrotatingathighspeedandmay
causeinjury.
• Checktheunitfoundationfordamageonacontinuous
basis,especiallyifithasbeeninuseforalongtime.If
leftinadamagedconditiontheunitmayfallandcause
injury.
• Placingaowervaseorothercontainerswithwateror
otherliquidsontheunitcouldcauseashockorreifa
spilloccurs.
• Nevertouchtheinternalpartsofthecontroller.Donot
removethecontrolboxlidbecausesomepartsinside
aredangeroustotouch.Tocheckandadjustinternal
parts,contactyourdealer.
• Besuretogroundtheunit.
Donotgroundtheunittoanutilitypipe,arrester,or
telephoneground.Incompletegroundingmaycause
electricshock,orre.Ahighsurgecurrentfromlight-
ningorothersourcesmaycausedamagetotheair
conditionerorheatpump.
• ThisequipmentcanbeinstalledwithaGround-Fault
CircuitBreaker(GFCI).Althoughthisisarecognized
measureforadditionalprotection,withtheearthing
systeminNorthAmerica,adedicatedGFCIisnot
necessary.
01_EN_3P184442-12W.indd 1 10/25/2017 15:57:37
ii English
CAUTION
• Donotusetheairconditionerorheatpumpforany
otherpurposesotherthancomfortcoolingorheating.
Donotusetheunitforcoolingprecisioninstruments,
food,plants,animalsorworksofart.
• Donotplaceitemsundertheindoorunitastheymay
bedamagedbycondensatesthatmayformifthehu-
midityisabove80%orifthedrainoutletgetsblocked.
• Beforecleaning,stoptheoperationoftheunitby
turningthepowerofforbypullingthesupplycordout
fromitsreceptacle.Otherwise,anelectricshockand
injurymayresult.
• Donotwashtheairconditionerorheatpumpwith
excessivewater.Anelectricshockorremayresult.
• Avoidplacingthecontrollerinaspotsplashedwith
water.Waterenteringthecontrollermaycausean
electricshockordamagetheinternalelectronicparts.
• Donotoperatetheairconditionerorheatpumpwhen
usingaroomfumigationtypeofinsecticide.Failureto
observethiscouldcausethechemicalstobedepos-
itedintheunitandcanendangerthehealthofthose
whoarehypersensitivetochemicals.
• Donotturnoffthepowerimmediatelyafterstopping
operation.Alwayswaitforatleastveminutesbefore
turningoffthepower.Otherwise,waterleakagemay
occur.
• Theapplianceisnotintendedforusebyyoungchil-
drenorinrmpersonswithoutsupervision.
• Theremotecontrollershouldbekeptawayfromchil-
drensotheycannotplaywithit.
• Consultwiththeinstallationcontractorforcleaning.
• Incorrectcleaningoftheinsideoftheairconditioneror
heatpumpcouldmaketheplasticspartsbreakand
causewaterleakageorelectricshock.
• Donottouchtheairinletoraluminumnoftheair
conditionerorheatpumpastheycancutandcause
injury.
NOTE
• Neverpressthebuttonoftheremotecontrollerwitha
hard,pointedobject.Theremotecontrollermaybe
damaged.
• Neverpullortwisttheelectricwireoftheremotecon-
troller.Itmaycausetheunittomalfunction.
• Donotplaceappliancesthatproduceopenamesin
placesthatareexposedtotheairowoftheunitor
undertheindoorunit.Itmaycauseincompletecom-
bustionordeformationoftheunitduetotheheat.
• Donotexposethecontrollertodirectsunlight.The
LCDdisplaycanbecomediscoloredandmayfailto
displaythedata.
• Donotwipethecontrolleroperationpanelwithben-
zene,thinner,chemicaldustcloth,etc.Thepanelmay
getdiscoloredorthecoatingcanpeeloff.Ifitisheavily
dirty,soakaclothinwater-dilutedneutraldetergent,
squeezeitwellandwipethepanelclean.Thenwipeit
withanotherdrycloth.
• Dismantlingoftheunit,disposaloftherefrigerant,oil,
andadditionalparts,shouldbedoneinaccordance
withtherelevantlocal,state,andnationalregulations.
• Operatetheairconditionerorheatpumpinasuf-
cientlyventilatedareaandnotsurroundedbyobsta-
cles.Donotusetheairconditionerorheatpumpinthe
followingplaces.
a. Placeswithamistofmineraloil,suchascuttingoil.
b. Locationssuchascoastalareaswherethereisa
lotofsaltintheair.
c. Locationssuchashotspringswherethereisalot
ofsulfurintheair.
d. Locationssuchasfactorieswherethepower
voltagevariesalot.
e. Incars,boats,andothervehicles.
f. Locationssuchaskitchenswhereoilmaysplatter
orwherethereissteamintheair.
g. Locationswhereequipmentproduceselectromag-
neticwaves.
h. Placeswithanacidoralkalinemist.
i. Placeswherefallenleavescanaccumulateor
whereweedscangrow.
• Donotattempttodoelectricalworkorgroundingwork
unlessyouarelicensedtodoso.Consultwithyour
dealerforelectricalworkandgroundingwork.
• Consultyourdealeriftheairconditionerorheatpump
inoperationgeneratesunusualnoise.
• Makesurethatthedrainpipeisinstalledproperlyto
drainwater.Ifnowaterisdischargedfromthedrain-
pipewhiletheairconditionerorheatpumpisinthe
coolingmode,thedrainpipemaybecloggedwithdust
ordirtandwaterleakagefromtheindoorunitmay
occur.Stopoperatingtheairconditionerorheatpump
andcontactyourdealer.
01_EN_3P184442-12W.indd 2 10/25/2017 15:57:37
1
English
CONTENTS
SAFETY CONSIDERATIONS.....................................[i] [ii]
1. NAMES AND FUNCTIONS OF PARTS............................ 1
2. MAINTENANCE
(FOR SERVICE PERSONNEL) ....................................... 1
1. NAMESANDFUNCTIONSOFPARTS
a
b
c
d
e
f
g
h
i
j
k
l
m
n
o
p
aDrain pump (Built-in)
bDrain pan inspection window
c
Remote controller (Optional accessory)
Depending on the system conguration, the remote
controller is not provided.
dPower supply wiring
eAir outlet grille (Field supply)
fExhaust duct (Field supply)
gRefrigerant piping
hDrain piping
iName plate
jAir lter (Optional accessory)
kSuction lter chamber (Optional accessory)
lSuction duct (Field supply)
mSuction grille (Field supply)
n
Ground wiring
The wiring passes electricity from the inside unit to
the earth to prevent accidental electrical shock.
oTransmission wiring
pRemote controller wiring
2. MAINTENANCE
(FORSERVICEPERSONNEL)
ONLYAQUALIFIEDSERVICEPERSONIS
ALLOWEDTOPERFORMMAINTENANCE
WARNING
• Donotuseammablegas(suchashairspraysand
insecticides)neartheairconditioner.
• Donotwipetheairconditionerwithbenzineorthinner.
Itmaycausecracks,electricshocksorare.
CAUTION
• Donotwashtheairconditionerwithwater.
Itmaycauseelectricshocksorareduetoleakage.
• Makesuretoturnofftheairconditionerwhentaking
careoftheairconditioneranddisconnectthepower
supplybreaker.
Unlessthepowersupplyisdisconnected,itmaycause
electricshocksandinjuries.
• Whenworkingatahighplace,givecautiontoyour
footing.
Ifthescaffoldisunstable,itmaycauseinjuriesdueto
fallandstumbling.
HOW TO CLEAN THE AIR FILTER
When the remote controller indicates “Time to clean lter”,
clean the air lter.
• The indication is made after the system runs for a dened
period of time.
NOTE
• You may change the time of indication “Time to clean lter”.
Iftheindoorunitisusedinaspacewheretheairis
morecontaminated,askyourlocaldealerforsolution.
Dust level Time until indication is displayed
Normal
2500 hours (equivalent to one year)
More contaminated
1250 hours (equivalent to a half year)
• If it becomes difcult to remove dust from the air lter,
replace the air lter.
(The replacement air lter is an optional accessory.)
Increase the frequency of cleaning if the unit is installed in a
room where the air is extremely contaminated.
01_EN_3P184442-12W.indd 1 10/25/2017 15:57:38
2English
NOTE
• Do not remove the air lter except when cleaning. Unneces-
sary handling may damage the lter.
(This product is not provided with an air lter as a standard
accessory.)
• Do not attach objects other than the genuine air lter (e.g.,
kitchen paper) to the air inlet.
Otherwise, the performance of the air conditioner will be
degraded, and icing or water leakage may result.
• This product is a ceiling mounted duct type air conditioner.
Installingunderroof
If the air lter (eld supply) is used, request a special con-
tractor for the cleaning of the air lter.
Notinstallingunderroof
Always use the long-life lter chamber (eld supply). Be
sure to request your dealer for the installation of the long-
life chamber. For the methods of mounting, dismounting,
and cleaning the air lter, refer to the manual provided with
the air lter.
• Besuretousetheoptionallterchamber.
Request your dealer for the installation of the lter chamber.
• Be sure to clean the air lter at the beginning of the cooling
or heating season.
(A decrease in the airow volume of the air conditioner will
result and the performance of the air conditioner will be
degraded if the air lter is clogged with dust or dirt.)
Aftercompletingcleaningandinstallingtheairlter,turn
offtheindication“Timetocleanlter”ontheremote
controller.
• The indication can be turned off whether in operation or at
stop.
• For details, refer to the operation manual attached to the
remote controller.
HOWTOCLEANAIROUTLET,OUTSIDEPANELS
AND REMOTE CONTROLLER
1. Clean with soft cloth.
2. When it is difcult to remove stains, use water or neutral
detergent.
NOTE
• Donotwashthesuctiongrillewithwaterof122°F
(50°C)orhigher.
Itmaycausediscolorationanddeformation.
• Whendryingthesuctiongrille,donotheatitwithre.It
maycauseburning.
• Donotusesubstancessuchasgasoline,benzine,
thinner,polishingpowderandliquidinsecticidesoldin
themarket.
Itmaycausediscolorationanddeformation.
WHATTODOWHENSTARTUPAFTERALONG
PERIODOFNOUSE
Conrmthefollowing
• Check that the air inlet and outlet of indoor and outdoor
units are not blocked.
Remove any obstacle.
Obstacles decrease the fan speed, and cause performance
decrease and may damage the unit.
Cleantheairlter
• After cleaning the air lter, make sure to reinstall it.
(Refer to “2.MAINTENANCE” on page 1.)
• For information on how to install, remove, or clean the
optional air lter, refer to the user’s manual attached to the
air lter.
• Turn off the indication “Time to clean lter” displayed on the
remote controller after turning on the power.
The indication can be turned off whether in operation or at
stop.
• For details, refer to the operation manual attached to the
remote controller.
Turnonthepowercircuitbreakeratleast6hoursbefore
operation.
• This is required in order to activate the air conditioner
smoothly, and to protect air conditioner.
• The display on the remote controller will be shown when
the power circuit breaker is turned on.
01_EN_3P184442-12W.indd 2 10/25/2017 15:57:38
[1711] HT
3P184442-12W EM17A014
00_CV_3P184442-12W.indd 3 9/4/2017 13:36:54

This manual suits for next models

10

Other Daikin Air Conditioner manuals

Daikin ATKM50QRV16 User manual

Daikin

Daikin ATKM50QRV16 User manual

Daikin VRV-W IV User manual

Daikin

Daikin VRV-W IV User manual

Daikin RXS30LVJU User manual

Daikin

Daikin RXS30LVJU User manual

Daikin RTSYQ10PY1 User manual

Daikin

Daikin RTSYQ10PY1 User manual

Daikin FWZ Quick start guide

Daikin

Daikin FWZ Quick start guide

Daikin Altherma 3 R F User manual

Daikin

Daikin Altherma 3 R F User manual

Daikin CONVENI-PACK User manual

Daikin

Daikin CONVENI-PACK User manual

Daikin FFQ09Q2VJUFFQ12Q2VJUFFQ15Q2VJUFFQ18Q2VJURX09QMVJURX12QMVJURX15QMVJURX18QMVJU User manual

Daikin

Daikin FFQ09Q2VJUFFQ12Q2VJUFFQ15Q2VJUFFQ18Q2VJURX09QMVJURX12QMVJURX15QMVJURX18QMVJU User manual

Daikin FTXA25A2V1BW User manual

Daikin

Daikin FTXA25A2V1BW User manual

Daikin CTXM15R2V1B How to use

Daikin

Daikin CTXM15R2V1B How to use

Daikin RX-JV Instruction manual

Daikin

Daikin RX-JV Instruction manual

Daikin McQuay IM 934-5 Instruction Manual

Daikin

Daikin McQuay IM 934-5 Instruction Manual

Daikin FXTQ12PAVJU User manual

Daikin

Daikin FXTQ12PAVJU User manual

Daikin RXF50D5V1B How to use

Daikin

Daikin RXF50D5V1B How to use

Daikin ATKC09RV2S User manual

Daikin

Daikin ATKC09RV2S User manual

Daikin FTXP50N2V1B User manual

Daikin

Daikin FTXP50N2V1B User manual

Daikin BRC7E63W User manual

Daikin

Daikin BRC7E63W User manual

Daikin FTKS20CVMB User manual

Daikin

Daikin FTKS20CVMB User manual

Daikin FXAQ07MVJU User manual

Daikin

Daikin FXAQ07MVJU User manual

Daikin RZQ18PVJU8 User manual

Daikin

Daikin RZQ18PVJU8 User manual

Daikin EWAQ004BAVP User manual

Daikin

Daikin EWAQ004BAVP User manual

Daikin FDA125A5VEB User guide

Daikin

Daikin FDA125A5VEB User guide

Daikin FXFQ20P9VEB Instruction manual

Daikin

Daikin FXFQ20P9VEB Instruction manual

Daikin ATXD50CV4 User manual

Daikin

Daikin ATXD50CV4 User manual

Popular Air Conditioner manuals by other brands

Gree GWH18TC-K3DNA1B/I Service manual

Gree

Gree GWH18TC-K3DNA1B/I Service manual

Be Cool BCP5AC2101F manual

Be Cool

Be Cool BCP5AC2101F manual

Sealey sac9000.V3 instruction manual

Sealey

Sealey sac9000.V3 instruction manual

McQuay MCK020A Technical manual

McQuay

McQuay MCK020A Technical manual

Haier HDU-42HT03/H Operating & installation manual

Haier

Haier HDU-42HT03/H Operating & installation manual

Fujitsu AOU48RLXFZ1 installation manual

Fujitsu

Fujitsu AOU48RLXFZ1 installation manual

Mitsubishi Electric MSC-GE20VB operating instructions

Mitsubishi Electric

Mitsubishi Electric MSC-GE20VB operating instructions

PR KLIMA GPC10AL operating instructions

PR KLIMA

PR KLIMA GPC10AL operating instructions

Arcoaire R4A3 installation instructions

Arcoaire

Arcoaire R4A3 installation instructions

LG LMU180CE owner's manual

LG

LG LMU180CE owner's manual

Panasonic CS-MKE7NKU Technical & service manual

Panasonic

Panasonic CS-MKE7NKU Technical & service manual

DEVOLA DVCO60P user manual

DEVOLA

DEVOLA DVCO60P user manual

Nortek AB 225 Installation and operating manual

Nortek

Nortek AB 225 Installation and operating manual

Hitachi RAS-70YHA1 instruction manual

Hitachi

Hitachi RAS-70YHA1 instruction manual

Frigidaire FFMS121CQ10 installation manual

Frigidaire

Frigidaire FFMS121CQ10 installation manual

Carrier CRTWOPOS007A00 installation instructions

Carrier

Carrier CRTWOPOS007A00 installation instructions

Allied Air 4SCU14LE SERIES Installation and maintenance instructions

Allied Air

Allied Air 4SCU14LE SERIES Installation and maintenance instructions

Bosch Climate 5000 MS 42 OU installation instructions

Bosch

Bosch Climate 5000 MS 42 OU installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.