Si37-701
Table of Contents iii
Part 6 Troubleshooting ............................................................. 209
1. Symptom-based Troubleshooting .......................................................212
2. Troubleshooting by Remote Controller ...............................................215
2.1 The INSPECTION / TEST Button.........................................................215
2.2 Self-diagnosis by Wired Remote Controller .........................................216
2.3 Self-diagnosis by Wireless Remote Controller .....................................217
2.4 Inspection Mode ...................................................................................220
2.5 Remote Controller Service Mode .........................................................221
2.6 Test Run Mode.....................................................................................223
2.7 Remote Controller Self-Diagnosis Function .........................................223
3. Troubleshooting by Indication on the Remote Controller ....................230
3.1 “A0” Indoor Unit: Error of External Protection Device............................230
3.2 “A1” Indoor Unit: PC Board Defect ........................................................231
3.3 “A3” Indoor Unit: Malfunction of Drain Level Control System (S1L) ......232
3.4 “A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................234
“A6” Indoor Unit: Malfunction of Indoor Unit Fan Motor.........................236
“A6” Indoor Unit: Overload / Overcurrent /
Lock of Indoor Unit Fan Motor..............................................................237
3.5 “A7” Indoor Unit: Malfunction of Swing Flap Motor (M1S).....................238
3.6 “A9” Indoor Unit: Electronic Expansion Valve Malfunction /
Dust Clogging.......................................................................................240
“A9” Indoor Unit: Malfunction of Electronic Expansion Valve Coil.........242
3.7 “AF” Indoor Unit: Drain Level above Limit .............................................244
3.8 “AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........245
3.9 “C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................246
3.10 “C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes .........247
3.11 “C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........248
3.12 “CJ” Indoor Unit: Malfunction of Thermostat Sensor in
Remote Controller ................................................................................249
3.13 “E1” Outdoor Unit: PC Board Defect .....................................................250
3.14 “E3” Outdoor Unit: Actuation of High Pressure Switch..........................251
3.15 “E4” Outdoor Unit: Actuation of Low Pressure Sensor..........................253
3.16 “E5”Outdoor Unit: Inverter Compressor Motor Lock.............................255
3.17 “E6”Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............257
3.18 “E7”Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................258
3.19 “E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E~Y5E)...............................................261
3.20 “F3” Outdoor Unit: Abnormal Discharge Pipe Temperature..................263
3.21 “F6”Outdoor Unit: Refrigerant Overcharged.........................................265
3.22 “F9” Outdoor Unit: Malfunction of BS Unit Electronic
Expansion Valve...................................................................................266
3.23 “H7”Outdoor Unit: Abnormal Outdoor Fan Motor Signal ......................268
3.24 “H9” Outdoor Unit: Malfunction of Thermistor (R1T) for
Outdoor Air ...........................................................................................270
3.25 “J2”Outdoor Unit: Current Sensor Malfunction ....................................271
3.26 “J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R31, 32T, 33T) ....................................................................................272
3.27 “J4” Outdoor Unit: Malfunction of Temperature Sensor for
Heat Exchanger Gas (R2T or R11T)....................................................273