Daintree WWD2-2IW User manual

LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
Page 1 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
WWD2-2IW
Installation Guide
Product Overview
RISK OF ELECTRIC SHOCK
Disconnect power before servicing or installing product .
WARNING
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Save these instructions for future use.
IMPORTANT
To ensure the product warranty is valid, please ensure
all installation instructions and environmental conditions
for storage and operation are complied with.
Installation to be performed by factory trained or qualified
personnel.
Save These Instructions
Use only in the manner intneded by the manufacturer.
If you have any questions, contact the manufacturer.
Prepare Electrical Wiring
¥W hen replacing a line voltage switch, the
power must be off at the branch circuit
breaker. Bypass the line voltage switch to
provide uninterrupted power to the fixtures
and make sure the connection is properly
insulated before installing the wireless switch.
intended
The WWD2-2IW wireless dimmer is a batery powered
in-wall mount switch for use in zonal room control
or as par of a large wireless networked system. The
WWD2-2IW device installs into an existing junction
box to replace an existing switch providing a wire-
less solution that enables dimming and ON/OFF
commands to be delivered to luminaires in its com-
missioned space. The communication with the lumi-
naires or wireless controllers utilizes a secure a reliable
wireless connection which helps minimize installation
cost and complexity.
Electrical Requirements

Page 2 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide

Page 3 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
�
Installation of Device into Back Housing
Insert the back housing piece into
the junction box and secure with
two screws. Reference Installation
of Back Housing onto Junction Box
instructions Steps 5 and 6 on Page
2 for more details.
To reset the network of the device,
remove the faceplate from the
device. Then press and hold the
reset button for 5 seconds. Install
the faceplate back onto the device.
Press either dimming up or down
button to enter the pairing mode
to join the device to a network.
Separate the battery cover
from the device. Pull the two
plastic insulation strips out
of the battery compartment.
Put the battery cover back
on the device.
Network Reset
123
Install the main body of the
device into the back housing.
Install the faceplate onto the
device. Note: Device supports
the use of other standard
faceplates on the market.
45
Use two standard screwdriver
to remove the devices from
the back housing
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide

Page 4 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Installation Guide
�
Product Dimensions
123
45
The deviceÕs LED flashing
on for 2 seconds every 30
seconds indicates that the
batteries need to be
replaced.
Remove the device from
the back housing.
Install the main body of
the device into the back
housing.
Install the faceplate onto
the device. The device
will rejoin its network
automatically.
Separate the battery cover
from the device. Replace
the batteries with AAA
batteries. All batteries need
to be replaced at the same
time.
‘s
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide

Page 5 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
�
Button Functionality
LED Indicator
Up Button
Short press
Double short press
Hold
Down Button
Short press
Double short press
Hold
Lights ON at previous level
Lights ON at 100% output
Turn ON and dim up
Lights OFF
Lights ON at minimum dimming level
Turn ON and dim down or dim down if lights are already ON
Rapid flash (12 times per second)
for up to 30 seconds
Solid ON for 10 seconds
Flashes once (100ms duration)
Flashes ON 2 seconds every
30 seconds
Device is trying to join a network
Device successfully joined a network
Device has been activated while in the network
Batteries need to be replaced
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide

Page 6 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Technical Data
DESCRIPTION ARTICLE NO
Wireless Controls Wall Dimmer, In Wall, 2 Button, Battery WWD2-2IW
Product Specifications
Product Availablity
Dimensions
Weight
Power Supply
Battery Life
Operating Environment
Status Indicator
Mounting
Warranty
Purpose of Control
Construction of Control
Type 1 Action
Pollution Degree 2
114mm H x 70mm W x 36mm D
130g
(4) AAA 1.5V battery
5 years (normal operation)
-10¡C to 40¡C (Indoor Use Only)
Network join status, button triggered
Mounts into junction box
5 years
Operating Control
Independently Mounted
Product Certifications and Regulatory Marks
2405-2480 MHz
8 dBm
Frequency band of radio operation:
Maximum radio transmit power:
FCC ID: 2AS3F-WWD2IW
IC : 25008-WWD2IW
Operating Control
E486320
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide

Page 7 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
SupplierÕs Address (USA): 25825 Science Park, STE 400, Beachwood, OH 44122
SupplierÕs Phone: 1-866-855-8629
SupplierÕs Name: Current Lighting Solutions, LLC
Product Name: Wireless Wall Dimmer
Model No: WWD2-2IW
SupplierÕs Website: www.gecurrent.com
Supplier's Declaration of Conformity
47 CFR ¤ 2.1077 Compliance Information
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development CanadaÕs license-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference including interference that may cause undesired operation of the device.
FCC RF Exposure Statement: Specific Absorption Rate (SAR) is a measure of the rate of RF (radiofrequency) energy
absorption by the body from the source being measured. This equipment has been found to be exempt from the RF
Exposure SAR Evaluation when the device is installed such that a person's head will, in normal conditions, be 10mm
away from the transmitter and antenna of the device.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
ÑReorient or relocate the receiving antenna.
ÑIncrease the separation between the equipment and receiver.
ÑConnect the equipment into an outlet on a circuit different from that to which the receiver is connected.
ÑConsult the dealer or an experienced radio/ TV technician for help
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
WWD2-2IW
htp://.currentlighting.com
Supplier’s
Supplier’s
Supplier’s
Supplier’s
Canada’s
-
-
-
-
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage;
(2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le
fonctionnement.

Page 8 of 8
Rev 04/11/23
WWD2-2_InstallSheet_R01
currentlighting.com
© 2022 HLI Solutions, Inc. All rights reserved. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
e
.
SIMPLIFIED EU DECLARATION OF CONFORMITY:
Hereby, Current Lighting Solutions, LLC declares that the radio equipment type WWD2-2IW is in compliance with Directive
2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.gecurrent.com
WWD2-2IW is in compliance with Directive
LightOWL®Dual Technology Passive Infrared
and Acoustic Sensors (LODIA)
INSTALLATION INSTRUCTIONS
WWD2-2IW
Installation Guide
Table of contents
Other Daintree Dimmer manuals