Malfunction Probable cause Troubleshooting method
7
When connected to the mains, the
fan does not rotate, it does not
respond to controls.
Low air consumption.
Increased noise or vibration.
Burning odor.
Power supply is not connected.
Malfunction in the internal connection
Clogged ventilation system.
Impeller is clogged.
Fan is not secured or it is incorrectly
mounted.
Clogged ventilation system.
The mains wire is connected to L1 and L2.
It was necessary to address a specialist.
Clean the ventilation system.
Clean the impeller.
Eliminate the installation error.
Clean the ventilation system.
Connect the wires correctly
ATTENTION! The fan and auxiliary control equipment should be isolated from the power supply during
installation and/or maintenance. The equipment should be grounded (for 250, 315 models).
Storage and transportation rules
It is necessary to store the fan only in the manufacturer’s packaging in a ventilated room at a
temperature from +5°C to +40°C and a relative humidity of no more than 70% (at T = 25°C). Shelf life is 2
years from the date of manufacture. Products shall be transported by any type of transport, provided
that consumer or shipping containers are protected from the direct impact of atmospheric precipitation,
from the absence of displacement of transport places during transportation, from the absence of mutual
shocks during transportation and while ensuring the safety of the fans. Transportation shall be carried
out, in accordance with the rules in force for this mode of transport.
Disposal
This appliance is marked, in accordance with European Directive 2012/19/EU on the disposal of
old electrical and electronic equipment (waste electrical and electronic equipment – WEEE). This
Directive defines the EU-wide rules for the collection and disposal of old appliances.
At the end of their service life or failure of the fan or its components, they should be disposed of.
Disposal shall be carried out separately, according to material groups: plastic elements, metal
fasteners.
ATTENTION!
Dismantling and disassembly of the fan should be carried out by qualified specialists with a
complete disconnection from the power supply
Maintenance
• Disconnect the fan from the mains;
• Dismantle the fan by disconnecting the middle unit and removing it from the installation site;
• Remove dust from impeller blades using a soft dry brush or cloth;
• Clean the fan impeller blades using a detergent solution;
• Wipe all plastic parts with a soft cloth dampened with soapy water;
• Wipe all surfaces dry;
• Assemble the fan and reinstall;
• Cleaning is recommended every 6 months.
ATTENTION!
Do not get the cleaning solution on the electric motor!
Water entering the fan is not allowed!