manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. DALCNET
  6. •
  7. Controllers
  8. •
  9. DALCNET DMX-T4-ZONE User manual

DALCNET DMX-T4-ZONE User manual

DMX-T4-ZONE
Controller Touch
Manuale Dispositivo
Made in Italy
Rev. 2020-12-15
Pag.1/ 4
DALCNET S.r.l, Registered office: Via dei Laghi, 31 –36077 Altavilla Vicentina (VI) –Italy
Headquarters: Via Lago di Garda, 22 –36077 Altavilla Vicentina (VI) –Italy
VAT: IT0423100235 –Tel. +39 0444 1836680 - www.dalcnet.com –info@dalcnet.com
➢Product Description
▪1 to 5 color 4 zone universal DMX512 touch master panel, can also be
used as 1 to 5 color 4 zone universal RF remote control.
▪Each zone can be set as single color, dual color (WW / CW), RGB, RGBW or
RGB + CCT light type.
▪DMX signal output, compliant with standard DMX512 protocol,
compatible with any supplier's DMX decoder.
▪When used as an RF remote control, it is compatible with the DRC1224-
5CV (Remote Control and Receiver)
▪Ultra-sensitive high-strength glass touch panel with center touch color
wheel and backlight
▪Smooth and accurate colour adjustment by tapping the colour wheel.
▪Touch keys with LED indicator and sounds.
▪Black and white glass panel available.
➔For the complete and updated Device Manual, please consult the manufacturer's website http://www.dalcnet.com
➢Technical Specifications
Input and Output
Voltage in Input
85-265VAC
Current Input
Max 0.1 A
Output signal
DMX512, RF 2.4GHz
Warranty
Warranty
5years
About Dimming
Input signal
RF 2.4GHz + panel touch
RF Remote control
30m
Dimming level
256 levels
Dimming range
0-100%
Environment
Operation Temperature
Ta: -30°C ~ +55°C
Maximum temperature at tc
Tc: +85°C
IP rating
IP20
DMX-T4-ZONE
Controller Touch
Manuale Dispositivo
Made in Italy
Rev. 2020-12-15
Pag.2/ 4
DALCNET S.r.l, Registered office: Via dei Laghi, 31 –36077 Altavilla Vicentina (VI) –Italy
Headquarters: Via Lago di Garda, 22 –36077 Altavilla Vicentina (VI) –Italy
VAT: IT0423100235 –Tel. +39 0444 1836680 - www.dalcnet.com –info@dalcnet.com
➢Mechanical structure and installation
➢Wiring diagram
DMX-T4-ZONE
Controller Touch
Manuale Dispositivo
Made in Italy
Rev. 2020-12-15
Pag.3/ 4
DALCNET S.r.l, Registered office: Via dei Laghi, 31 –36077 Altavilla Vicentina (VI) –Italy
Headquarters: Via Lago di Garda, 22 –36077 Altavilla Vicentina (VI) –Italy
VAT: IT0423100235 –Tel. +39 0444 1836680 - www.dalcnet.com –info@dalcnet.com
➢Key functions
Each zone can correspond to a single-color, dual-color (WW/CW), RGB, RGBW, or RGB+CCT(WW/CW) controller or lamp.
To enter the zone light setting:
1. Tap the power button to turn on the light,
2. Press the power button again to turn off the light.
3. Hold down the power button immediately for 5 seconds,
4. As soon as I enter the setting, press 1/2/3/4 Zone to set them.
For example, if you want to change the light type of zone 1 as an RGB type, press the Zone 1 button for 2 seconds for a long time, and then press indicator
for 2 seconds, doing so sets Zone 1 as RGB type.
If zone 1 indicator is set like this: we'll only have one color to set
If zone 1 indicator is set like this: Double color to set
If zone 1 indicator is set like this: RGB to set
If zone 1 indicator is set like this: RBGW to set
If zone 1 indicator is set like this: RGB+CCT to set
If you want to change zone 2/3/4, press the Desired Zone button for 2 seconds, then repeat the steps described above.
Short press on the ON/OFF button or on the color wheel or waiting for time-out 10 seconds, you will exit the area light type setting.
The short pressure turns on the zone light and selects the zone at the same time. Press 2s for a long time to turn off the zone light.
There are 4 separate or synchronous zone controls, each zone could control multiple receivers.
Only multiple zones with the same light type can be selected synchronously.
Turn the light on or off
One touch starts 10 dynamic models, a touch of 2 sec. starts a mode-
cycle
RGB/Color Temperature
Press RGB or CCT to change from RGB to CCT
One tap to repeat scenes. Long press for 2 sec. saves the color in the
scene. Recall the 4 scenes or save them in sync.
24-level RGB
Adjust the brightness, one touch set 10 levels of brightness, pressing for
1-6 sec adjust the brightness up to 256 levels continuously.
For double colors or RGB+CCT(WW/CW), adjust temperature with
WW/CW channels. A short press set 11 levels of tunable white, if
pressed for 2 seconds sets the maximum or minimum color temperature
available in the channel.
For RGB adjust the temperature color doing a mix on R G B channels;
can set 11 tunable white levels.
For RGBW adjusts the brightness of the W channel, until 11 levels. A
longer tap of 2 seconds brings the brightness of the White channel to
100% or 0%.
RGB mode: with a short touch it sets up to 10 levels of colour rotation
speed, keeping the button pressed for 2s goes to the default speed.
For static RGB colour, adjust the saturation, i.e., short pressing the
button slowly changes the current static RGB colour to white up to 11
levels, instead long pressing for 1-6s adjusts continuously the colours up
to 256 levels.
DMX-T4-ZONE
Controller Touch
Manuale Dispositivo
Made in Italy
Rev. 2020-12-15
Pag.4/ 4
DALCNET S.r.l, Registered office: Via dei Laghi, 31 –36077 Altavilla Vicentina (VI) –Italy
Headquarters: Via Lago di Garda, 22 –36077 Altavilla Vicentina (VI) –Italy
VAT: IT0423100235 –Tel. +39 0444 1836680 - www.dalcnet.com –info@dalcnet.com
Note:
1. For the single color, the RGB/CCT touch wheel changes only brightness. RGB, MODE, SPEED buttons are invalid.
2. For dual color, tapping the RGB/CCT wheel will only change the color temperature. RGB, MODE, SPEED buttons are invalid.
3. For RGB, when you tap the CCT wheel, adjust the color temperature based on the R/G/B mix channel.
4. For RGBW, when you tap the CCT wheel, adjust the brightness of the W channel.
5. Turn on/off the tone of the button: Press the power button to turn off all lights and wait 5 seconds after closing. Press for 10s power button when all the
lights in the area are turned off, the tone turns on or off.
➢Dmx512 master
Light type
Light channel
Zona1 DMX
address
Zona2 DMX
address
Zona3 DMX
address
Zona4 DMX
address
Single color
W W W W W
1-5
6-10
11-15
16-20
Double color
WW CW WW CW 0
1-5
6-10
11-15
16-20
RGB
R G B 0 0
1-5
6-10
11-15
16-20
RGBW
R G B W W
1-5
6-10
11-15
16-20
RGB+CCT
R G B WW CW
1-5
6-10
11-15
16-20
➢Dynamic Mode List
No.
Name
No.
Name
1
RGB jumps
6
RGB fade in and out
2
RGB smooth
7
Red fade in and out
3
6 color jumps
8
Blue fade in and out
4
6 color smooth
9
Green fade in and out
5
Smooth color temperatures
10
White fade in and out
➢Manage the panel as a remote RF
USE THE CONTROLLER MATCH KEY
USE POWER RESTART
Match:
Press the match button, immediately press the zone button of the
touch panel.
Delete:
Hold down the match button for 5s to eliminate all matches, lighting
lights 5 times means that all paired remote controls have been
deleted and is ready to use.
Match:
Turn off the receiver power supply, then turn on the power again,
immediately press the Zone button 3 times on the touch panel. If
the light flashes 3 times means that the match is successful.
Delete:
Turn off the receiver power supply, then turn on the power again,
immediately press the Zone button 5 times on the touch panel. If
the light flashes 5 times means that all paired remote controls have
been eliminated.

Other DALCNET Controllers manuals

DALCNET DTDMXRGBW Release Note

DALCNET

DALCNET DTDMXRGBW Release Note

DALCNET DTDMX16C Release Note

DALCNET

DALCNET DTDMX16C Release Note

DALCNET DRC1224-5CV User manual

DALCNET

DALCNET DRC1224-5CV User manual

DALCNET DSL-5A-SPI-KIT Application guide

DALCNET

DALCNET DSL-5A-SPI-KIT Application guide

Popular Controllers manuals by other brands

Mitsubishi FX-32E-TB/UL Hardware manual

Mitsubishi

Mitsubishi FX-32E-TB/UL Hardware manual

JUMO DICON touch operating manual

JUMO

JUMO DICON touch operating manual

Future light CP16 user manual

Future light

Future light CP16 user manual

Emerson Alco Controls EC3 Series operating instructions

Emerson

Emerson Alco Controls EC3 Series operating instructions

omal automation AE 10 instruction manual

omal automation

omal automation AE 10 instruction manual

RTI T4 Installation & operation guide

RTI

RTI T4 Installation & operation guide

TeeJet 855 Installation and operating manual

TeeJet

TeeJet 855 Installation and operating manual

Texas Instruments TMS320x281 series reference guide

Texas Instruments

Texas Instruments TMS320x281 series reference guide

Omron SYSMAC C200H CPU01-E installation guide

Omron

Omron SYSMAC C200H CPU01-E installation guide

Omron E5 R brochure

Omron

Omron E5 R brochure

LiteOn EVO600021S0D2E20F user manual

LiteOn

LiteOn EVO600021S0D2E20F user manual

Savant SmartLighting SSL-P018 Quick reference guide

Savant

Savant SmartLighting SSL-P018 Quick reference guide

BN Thermic OUH3-WiFi instructions

BN Thermic

BN Thermic OUH3-WiFi instructions

Cisco WS-C5008B - Power Supply - 1100 Watt installation guide

Cisco

Cisco WS-C5008B - Power Supply - 1100 Watt installation guide

SOMFY animeo IB 9011809 installation guide

SOMFY

SOMFY animeo IB 9011809 installation guide

Danfoss EKC 316A instructions

Danfoss

Danfoss EKC 316A instructions

Samson 3372 Mounting and operating instructions

Samson

Samson 3372 Mounting and operating instructions

SpectraPure UltraPrecise ATO installation manual

SpectraPure

SpectraPure UltraPrecise ATO installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.