Dalsa Touch GEVA Series User manual

GV-312T
Touch Series GEVA Vision System
Installation Manual
405-00046-00
September 9, 2014
Revision 1.1

2
Notice
GV-312T Installation Manual
Document Number 405-00046-00
Revision: 1.1
Copyright 2014 Teledyne DALSAIncorporated.
All rights reserved.
All copyrights in this manual, and the hardware and software described in it, are the
exclusive property of Teledyne DALSAIncorporated and its licensors.
Claim of copyright does not imply waiver of Teledyne DALSAIncorporated or its
licensors other rights in the work. See the following Notice of Proprietary Rights.
NOTICE OF PROPRIETARY RIGHTS
This manual and the related hardware and software are confidential trade secrets
and the property of Teledyne DALSAIncorporated and its licensors. Use,
examination, reproduction, copying, transfer and/or disclosure to others of all or
any part of this manual and the related documentation are prohibited except with
the express written consent of Teledyne DALSA Incorporated.
The information in this document is subject to change without notice. Teledyne
DALSAIncorporated makes no representations or warranties with respect to the
contents of this manual and specifically disclaims any implied warranties of
merchantability or fitness for a particular purpose.Teledyne DALSAIncorporated
assumes no responsibility for errors or omissions in this document.
iNspect Express, Sherlock, and the Teledyne DALSAlogo are trademarks of
TeledyneDALSA Incorporated.All other trademarks are the property of their
respective owners.
Teledyne DALSA Industrial Products
Information: info.ipd@teledynedalsa.com
Support: support.ipd@teledynedalsa.com
Web: http://www.teledynedalsa.com/visionsystems
700 Technology Park Drive
Billerica, MA, USA 01821
Tel 1.978.670.2002 Fax 1.978.670.2010

3
Certifications
Declaration of Conformity
Supplier Teledyne DALSA Industrial Products Inc.
700 Technology Park Drive
Billerica MA 01821
USA
CE This product is in compliance with the directives of the
European Union. It has passed the CE test for environmental
specifications when shielded cables are used for external
wiring. A certificate of compliance is available upon request.
FCC This product has been tested and found to comply with the
limits for a class A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation.
This equipment generates, uses and can radiate radio
frequency energy and may cause harmful interference to radio
communication.

4
Care should always be exercised when handling and operating this product. Even
though the system is encased within a rugged, industrial enclosure, incorrect use or
handling can result in damage to your investment. To prevent this, you should avoid the
following:
Handling Precautions
•Hot-plugging cables and devices. Be sure to shut the system down and remove
power before connecting or disconnecting anything to it.
•Free-standing operation. It is advisable to mount the system properly to prevent it
from falling accidentally. Mounting hardware is provided with the system.
•Do not place hard or sharp objects directly on or against the touch screen.Avoid
exposing the touch screen to direct sunlight for prolonged periods.
•Operating the system in an environment outside of it’s recommended operating
conditions.
•Avoid the damage that ESD can cause. Never expose the internal electronics to a
potentially hazardous environment by opening the enclosure. Doing so may cause
serious damage.
User Service Warning
With the exception of the externally accessible CFAST solid state drive, this product has
no field-replaceable component. Tampering with the unit will void the product warranty.
Warranty
Teledyne DALSA warrants the GV-312T against defects in materials and workmanship
for a period of Twelve (12) months from the date of delivery. Teledyne DALSA and its
representatives expressly disclaim any and all other warranties.
Your sole remedy shall be repair or replacement of this product and associated optional
components, provided that the defective product is returned within the warranty period.
TeledyneDALSA assumes no liability for any damages, lost profits, lost savings or
consequential damage resulting from the use, misuse of, or inability to use this product.
If you need to return the product, you must contact the Teledyne DALSArepresentative
who sold it to you. Do not return your product to Teledyne DALSAwithout prior
authorization.

5
Table Of Contents
Introduction GV 312T Introduction ……………………............................... 6
System Components ……………………............................... 6
Product Support ……………………............................... 7
Installation Installation ……………………............................... 8
Panel Mount ……………………............................... 10
VESA Mount ……………………............................... 12
GigE Cameras ……………………............................... 13
Typical Configuration
using the PL-USB ……………………............................... 14
Typical Configuration
not using the PL-USB ……………………............................... 15
Software Getting Started ……………………............................... 16
Directory Structure ……………………............................... 16
The License Manager ……………………............................... 17
iNspect Express Setup ……………………............................... 18
Camera Selector ……………………............................... 19
iDiscover ………………………………………….. 20
Sherlock Setup ……………………............................... 21
Sapera CamExpert ……………………............................... 22
Sapera Acquisition
Wizard ……………………............................... 23
Changing Camera
Order ……………………............................... 24
Enhanced Write Filter ……………………............................... 25
Specifications GV-312T Specifications ……………………............................... 26
Mechanical Drawings ………………………………………….. 27
Appendix A Touch Screen
Calibration ………………………………………….. 28

6
Introduction
GV 312T is a low cost vision system with an integrated touch panel interface for
configuring and monitoring automated camera inspections on the factory floor. The
product is equipped with hardware interfaces and application software to support the
following:
•Detection and maintenance of GigE cameras on the local network
•Setup and modification of inspection solutions without requiring an external PC
•Runtime monitoring of inspections (operator interface)
•Runtime tool parameter editing
•Offline solution debugging using built-in emulation
The GV 312T system utilizes a dual-core processor running the Windows 7 Embedded
operating system. As such, users have the option of developing their own custom
operator interface instead of using the pre-installed interfaces supplied with the product.
Camera Network
PLC (if required)
Typical GV 312T System Setup
I/O Connections
USB LAN1LAN2
PL-USB
GV 312T
Switch

7
GV 312 Vision Systems are shipped with the components listed below. Take a few
moments to verify that everything has arrived in good condition. If your product has
been visibly damaged during shipment or is missing parts, please contact your Teledyne
DALSArepresentative immediately.
GV 312T System Components
Component Description
GV312T-XX GV 312T. 12” touch panel vision system. Includes Win7-
32bit Embedded O/S, 32 GB CFAST SSD, front panel mount
hardware clips, iNspect Express software (-03), Sherlock
software (-04).
Standard components (ship with every GV 312T):
Component Description
A-VESA-T VESA mounting hardware
A-PWR-24 DIN mountable 24VDC power supply
A-CAM-XXXXXX-XX Genie GigE cameras
A-CAB-GE-X Ethernet cables
A-CAB-GEVA-FX GEVA I/O cables
A-PL-USB USB I/O breakout module
Optional components (Partial listing shown):
Product Support
This manual will assist you with the installation and setup of your GV 312Tproduct and
the embedded software. It describes what the product supports and how to connect the
external interfaces. If your questions are not answered in this reference, please contact
your local Teledyne DALSArepresentative.

8
Installation
Review user interface controls, connections and mounting holes
1 2
3
Front View
1. Reset button – front accessible USB port
2. 12” Touch LCD display (refer to appendix A for touch screen calibration)
3. Press control function keys as follows:
2

9
Installation
1 2
Bottom View
1. Power Input – 24 VDC.
2. Four RS-232 ports
3. DVI port for optional 2nd display
4. Two Gigabit Ethernet ports. Default IP settings are as follows (these can optionally
be changed through the Windows network “adapter change settings” interface):
Marking Default IP Connection
LAN1 Dynamic IPAddress DHCP enabled LAN network
LAN2 Static IPAddress 192.168.11.1 Camera Port 1
LAN left LED: Off = 10 Mbits/s; GREEN = 100 Mbits/s; ORANGE = 1000 Mbits/s
LAN right LED: ON = port active; BLINK = port traffic
Jumbo frames enabled on Camera Port, not enabled on LAN1 port.
NOTE: Genie Ethernet cables must be type Cat5 or Cat5e.
5. Four USB 2.0 ports
4 53

10
Installation
Mount the Unit (Panel Mount)
Locate the panel mounting clips included with the product. Put the clamps
into the holes located on the sides of the product as shown:

11
Installation
Attach the rubber gasket included in the mounting kit around the inside
back lip of the panel.
Place the GV 312T into the correct-sized cutout on a control panel or frame
and tightly screw the panel-mounting clamps around the edges to secure
the product.

12
Installation
Mount the Unit (VESA mount)
Some applications may require mounting the GV 312T to a VESA
compatibleARM. This requires an optional mounting bracket (A-VESA-T)
that should be purchased with the unit. Take the bracket assembly and
attach it to the back and sides of the product as shown below. Make sure
not to cover the door of the CFAST flash drive.
A-VESA-T
CFAST Door
Left side assembly Right side assembly

13
The GV 312T supports Teledyne DALSA Genie cameras for image acquisition. These
include the Genie series and the Genie TS series. The Spyder GigE line scan series is
not recommended for this product.
The Genie family, including the TS series, offers a range of sensor resolution from
640x480 up to 4096x3072 pixels. Resolutions up to 1600x1200 are available in both
mono and color formats. The following should be noted when matching your application
camera needs to the GV 312T:
1.Sherlock has no limit on the number of cameras supported.
2.iNspect Express “Standard” license supports up to 4 cameras.
3.iNspect Express “Extended” license supports up to 8 cameras.
4.The GV 312T hardware design does not limit how multiple cameras are connected. In
theory, multiple cameras could be connected through Ethernet switches to the GV 312T
camera port. However, in practice, the effective throughput of the system will decrease
as you add more cameras, higher resolution or color formatting. Consult with your
TeledyneDALSA representative on applications requiring more than 4 cameras or high
inspection speeds.
iNspect Express and Sherlock use different software drivers to interface GigE cameras.
iNspect Express uses a driver called IFC, whereas Sherlock uses one called Sapera LT.
The setups associated with each will be described later in the manual. Generally,
Sapera offers additional flexibility over IFC, but requires additional steps to setup.
Two cables are needed in the setup of each Genie camera. The data cable (A-CAB-GE-
X) connects the camera’s Ethernet port to one of the GV 312T camera ports. The I/O
cable provides power to the camera and access to the camera’s I/O, including trigger.
When using the PL-USB module (Genie camera breakout module), the standard GEVA
cable should be used (A-CAB-GEVA-FX). This method offers more flexibility and
greater I/O control. If you are not using the PL-USB breakout module, the standard
Genie trigger cable can be used (A-CAB-GTP-X). Choice of one over the other is
application dependent.
Note: By default, iNspect Express and Sherlock assume Genie camera Input2 is the
trigger input and Genie camera Output2 is the strobe output.
GigE Cameras

14
Typical Configuration using the PL-USB module
NOTES:
1. Power connections not shown
2. Use A-CAB-GE-X for camera Ethernet connections
3. Use A-CAB-GEVA-FX for I/O connections between
camera and PL-USB
Setup/Operator HMI
(iNspect Express shown)
Camera Network
I/O Connections
USB LAN2
PL-USB
GV 312T
Switch

15
Typical Configuration without the PL-USB module
NOTES:
1. Power connections not shown
2. Use A-CAB-GE-X for camera Ethernet connections
3. Use A-CAB-GTP-FX cables for camera power
Setup/Operator HMI
(Sherlock shown)
Camera Network
I/O Connections
LAN2
GV 312T
Switch

16
Software Interface
The GV 312T vision system is supplied with either iNspect Express or Sherlock vision
software installed. These applications offers a suite of vision capabilities that satisfy a
diverse range of automated inspection needs. The following shows how to configure the
GV 312T to work with either interface. Refer to the respective software user manual for
more information.
Getting Started
Software Directory Structure
iNspect Express, Sherlock and associated software applications are installed in various
directories on the GV 312T. For reference, the following table lists the location and
association of core programs and data directories that are referenced in this manual:
NOTE: Both iNspect Express and Sherlock have a Start Menu shortcut to the User
Files directory. The C:\Users\Teledyne\AppData directory (and everything below it) is
normally hidden per Windows rules.
iNspect Express Program Files and Directories
CameraSelector C:\ProgramFiles\TeledyneDalsa\iNspectExpressfor VA\CameraSelector.exe
iNspectExpress C:\ProgramFiles\TeledyneDalsa\iNspectExpress for VA\Express.bat
iNspectExpress SolutionFiles C:\Users\Teledyne\AppData\Local\TeledyneDalsa\iNspectExpressVA\Solutions
iNspectExpress EmulatorImages C:\Users\Teledyne\AppData\Local\TeledyneDalsa\iNspectExpressVA\Images
iDiscover C:\ProgramFiles\TeledyneDalsa\iNspectExpress for VA\iDiscoverGenie.exe
LicenseManager C:\ProgramFiles\TeledyneDalsa\iNspectExpress for VA\IpdLicMgr.exe
Sherlock Program Files and Directories
Sherlock C:\ProgramFiles\TeledyneDalsa\Sherlock\bin\IpeStudio.exe
SherlockDrivers* C:\ProgramData\TeledyneDalsa\Sherlock\Drivers
SherlockPrograms* C:\ProgramData\TeledyneDalsa\Sherlock\Programs
SherlockEmulator Images* C:\ProgramData\TeledyneDalsa\Sherlock\Images
SaperaAcquisitionWizard C:\ProgramFiles\TeledyneDalsa\Sherlock\bin\IpeSaqAcqWiz.exe
SaperaCamExpert C:\ProgramFiles\TeledyneDalsa\SaperaLT\CamExpert\CamExpert.exe
iDiscover C:\IPDInstall Files\Utilites\iDiscoverGenie.exe
LicenseManager C:\ProgramFiles\TeledyneDalsa\Sherlock\bin\IpdLicMgr.exe
* The “ProgramData” paths apply when Sherlock is installed with the option “for all users”. The
path becomes “Users\Teledyne\AppData\Local” when installed for the “current user only”.

17
Software Interface
The License Manager
The software installed on the GV 312T is license protected. The license is applied to the
unit system number before it ships from the factory. Make sure that the product license
matches what you ordered before going any further. Open the license manager from the
“start menu” as follows:
Start->All Programs->Teledyne DALSA->iNspect Express for VA->License Manager OR
Start->All Programs->Teledyne DALSA->Sherlock->License Manager
If the license does not reflect what you purchased, consult your Teledyne DALSAsales
representative. The license is field upgradable by entering a new string in the box
above.

18
Follow these steps to configure the system to run iNspect Express:
1. Connect cameras as shown in the hardware installation
2. Verify a valid license is installed (run License Manager)
3. Open the Camera and Language Selector Program (from shortcut) and configure
preferences; Select “GigE” in the camera menu.
4. Click on the iDiscover button to detect and configure cameras connected to the
system
5. Save Camera set (select which connected cameras you want to use)
6. Close iDiscover and launch iNspect Express (run panel shown below)
iNspect Express Setup

19
This program is a front-end configuration tool for iNspect Express. Launch from the icon
on the GV 312T desktop. Select the language, camera type (always GigE for GV 312T)
and custom features for your application.These features are peculiar to the iNspect
Express software and are detailed in the software users manual.
From the camera selector tool you can launch both iDiscover and iNspect Express as
shown below. To launch the emulator simply select the “Virtual (DEMO) Camera”.
The Camera and Language Selector
Click to
launch
iDiscover
Click to
launch
iNspect
Express

20
The iDiscover utility is provided for discovering Genie cameras connected to the GV
312T camera port. Use the iDiscover interface to change the camera IP settings to
match the IP setting of the camera port. A shortcut to the iDiscover program is available
on the GV 312T desktop.
Click on one of the detected cameras to populate the associated network configuration
on the right. You can then modify the camera IP address to match the camera port IP
segment at the top. Click the “Apply” button to save changes. Note: Conflicting IP
addresses will be designated by a red camera icon in the detected camera menu.
Select cameras to use in your iNspect Express configuration by clicking and moving
them to the left panel using the arrow buttons. You can change the camera order by
using the up/down arrow buttons on the left control bar. Save the corrected camera list.
Note: For Sherlock applications, iDiscover is only used to detect and correct IP
conflicts. Clicking the “Save Camera Set” has no effect in Sherlock.
The iDiscover Utility
Click to save
configuration Click to return to
camera selector
This manual suits for next models
1
Table of contents
Other Dalsa Machine Vision System manuals
Popular Machine Vision System manuals by other brands

NI
NI CVS-1459 Getting started guide

Panasonic
Panasonic Micro-Imagechecker AX40 user manual

NET
NET Corsight CO1041C2 Operational manual

National Instruments
National Instruments NI myRIO ESSENTIALS GUIDE

National Instruments
National Instruments CVS-1459RT Getting started guide

SVS-Vistek
SVS-Vistek GIGA VISION ECO 4I/O manual

Sylvac
Sylvac VISIO 200 GL Instruction Manual Quick Start Version

AXIOMTEK
AXIOMTEK AIE100-903-FL-NX user manual

PhaseOne
PhaseOne iXM-MV150F installation guide

Welch Allyn
Welch Allyn Spot quick reference

Hyndsight Vision Systems
Hyndsight Vision Systems CRUZ Instructions for use

JAI
JAI SW-4010Q-MCL-M52 user manual