Service Manual PVG 32 ProportionalValve Group
System Troubleshooti n g
Cylinder/motor responds in one direction only
Main valve spool moveswithout oil passing to cylinder/motor
Cause Check Corrective action
Veriff if fault is mechanical, electrical
or hydraulic Operate manuallever in both directions to confirm if
mechanical or electrical or hydraulic lf moving the manual lever operates the cylinder/motor
in both directions check electrical or hydraulic
lf operating the manual lever strokes the cylinder/
motor in one direction only, check manual stop screw
adjustment
Back out manual stop on manual controller and torque
the jam not to 8 Nm [70 lbf.in] Do not exceed maximum
torque
Check movement of manual lever when electrical
controller is operated lf manual lever does not move in one direction check
electricalsignalfrom controller and wiring at the pVE
module
Check movement of manual lever when hvdraulic
controller is operated lf manual lever does not move in both directions check
hydraulic pressure at the PVG module
Air in system Entrained air generates heat under pressure Lookforfoam or bubbles in reservoir. Checkfor leak on
inlet side of charge pump.
Internalleakage Excessive internal leakage may overheat the system. Install loop flushing defeat option and monitor case flow.
lf case flow is excessive, motor may require major repair.
Contact Danfoss Service.
Shock valves Swap and see if problem follows Replace valves
Solenoid actuation lf power is OK from controller Repairwiring to PVE module
Main spool travel restricted Stop on manual controller turned in too far Back out manual stop on manual controller
Remote electrical controller Insufficient signal from electrical controller Repair or replace electrical controller
PVEO connections Incorrect PVE/PVEO con nections Connect correct way
Remote hydraulic controller PVRH Insufficient pilot oil pressure from remote hydraulic
controller Pressure needs to be 25 Bar [360 psi] Repair or replace remote hydraulic controller
Cause Check Corrective action
Insufficient oil supplyto valve Checkthe pump per manufacturers procedure Repair or replace pump per manufacturers procedure
Optional pressure compensator in
valve section not functioning Check compensator spool Replace spool
Insufficient load pressure at
compensator spring chamber LS drilling holes plugged Clean or replace
Cylinder/motor load too high for
pressure setting of the system Check pressure at the valve lf pressure is set to spec. per valve lower load on cylinder/
motor
Blocked LS galleries Inspect for blockage in LS galleries Remove blockage in LS galleries
Shuttle valve faulty lnspect shuttle valve Repair or replace
Blocked LS lines to pump controller Inspect LS lines from PCG to pump controller Remove blockage in LS lines from the PVG valve to pump
controller
Oil bypassing at shock valve/antF
cavitation check valve Check if stuck open or damaged Replace valve
Internal leakage in cylinder/motor Inspect for by-passing of oil per cylinder/motor
manufacture per manufactures proced u re Repair or replace cylinder/motor per manufactures
procedure
Too much leakage in LS spool in pump
control Check bleed orifice in LS control Use a LS pump controlwith no bleed orifice
Blocked thermal orifice check thermal orifice (blocked) Replace thermal orifice
Load too high for system check for proper system pressure Adjust pressure to valve specification
lnternal leakage in cylinder/motor Inspect for bypassing of oil per rylinder/motor
manufacturer specification Repair or replace cylinder/motor
Shock valve or anti-cavitation check
valve faulty lnspect for damage and contamination Repalr or replace cylinder/motor
System relief valve pressure set too low
for load Install pressure gauge and check pressure Adjust pressure to system specification
Lower load