OF SERIES
INSTRUCTION MANUAL
INSTALLATION
R
≥10
Use the AF5 adapter to connect thin fibre-optics ∅1 mm.
Use the AF11 cutting tool to cut the fibres to the desired
length.
Cutting fibres may reduce the operating range.
Always use cutting tools with the blade in perfect conditions.
Fibres models Efficiency
OF-xx-HT 70%
OF-xx-XF 90%
OF-xx-UF 90%
OF-xx-HP 125%
OF-xx-CL 65%
OF-xx-TN 35%
Normalized operating range relative to
∅
2.2 mm fibres
(OF-xx-ST).
Maximum torque
M3 nut M4 nut M6 nut
0.6 Nm 0.8 Nm 1.0 Nm
Materials
Optical fibres Sheath Tips
PMMA PE Nickel-plated brass
Never apply excessive mechanical stresses to
the fibres.
Never use organic dissolvents.
TECHNICAL DATA
Model Function Length
(m)
∅Sheath
(mm)
∅Fibres
(mm)
Bendable
sleeve
Tips Temp.
(°C)
R (> mm) Accessories
OF-18ST-10 Proximity 1 2.2 1 - M6 x 1 -30 … 60 25 -
OF-19ST-10 E/R 1 2.2 1 - M4 x 0.7 -30 … 60 25 -
OF-20CL-20 Proximity 2 2.2 1 - M6 x 1 -30 ... 60 25 -
OF-21CL-20 E/R 2 2.2 1 - M4 x 0.7 -30 ... 60 25 -
OF-22ST-20 Proximity 2 2.2 1
90 mm ∅2.5 M6 x 1 -30 ... 60 25 -
OF-23ST-20 E/R 2 2.2 1
90 mm ∅1.3 M4 x 0.7 -30 ... 60 25 -
OF-24ST-20 Proximity 2 2.2 1 - M4 x 0.7 -30 ... 60 25 -
OF-25TN-10 E/R 1 1 0.5 - M2 x 0.4 -30 ... 60 10 AF5
OF-26TN-10 Proximity 1 1 0.5 - M3 x 0.5 -30 ... 60 10 AF5
OF-28TN-10 Proximity 1 1 0.5
90 mm ∅1.3 M3 x 0.5 -30 ... 60 10 AF5
OF-36ST-20
OF-36XF-20 Coaxial prox. 2 2.2
1 x ∅1
+
16 x ∅0.25
- M6 x 1 -30 ... 60 25
5 -
OF-38ST-20 Proximity 2 2.2 1 -
15 mm ∅2.5 -30 ... 60 25 -
OF-42ST-20
OF-42HT-20
OF-42UF-20
OF-42HP-20
Proximity 2 2.2
1
1
1
1.5
- M6 x 0.75
-30 ... 60
-30 ... 125
-30 ... 60
-30 ... 60
25
25
2
25
AF7
OF-43ST-20
OF-43HT-20
OF-43UF-20
OF-43HP-20
E/R 2 2.2
1
1
1
1.5
- M4 x 0.7
M2.6 x 0.45
-30 ... 60
-30 ... 125
-30 ... 60
-30 ... 60
25
25
2
25
AF1
AF2
2 x AF9
OF-44ST-20
OF-44XF-20 Coaxial prox. 2 2.2
1 x ∅1
+
16 x ∅0.25
- M4 x 0.7 -30 ... 60 25
5
AF3
AF4
ACCESSORY DIMENSIONS
AF7
M6x0.75
Ø11.5
Ø7
1315
2000
6.5 3.5
16
M3
3
8
12
4.5
2
10
AF9
2
7
15
Ø9
M4x0.70
Ø7
6.5
2000
13
8
3
12
4.5
3.5
16
M3
8
3
Protective metal sheath.
Length: 2m, sheath: steel stainless, tips: alluminium
AF1
6.5
Ø4
M2.6x0.45
9.5
AF2
11.2
Ø4
M2.6x0.45
Radial mirror Long distance lens
AF3
Ø6.5
M4x0.7
12
5.1
AF4
M4x0.7
Ø6.5
5.1
15
High resolution lens
Spot size ∅4 mm to 19 mm
High resolution lens
Spot size ∅4 mm to 7 mm
AF5
Ø2.2
25
10
Ø1
Ø3.5
Thin fibres adapter (from ∅1 mm to ∅2.2 mm)
AF11
25
Ø1.1Ø2.2
46 8
Cutting tool for ∅2.2 mm and ∅1 mm fibres
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product
found to be defective during the warranty period of 36 months from the
manufacturing date.
This warranty does not cover damage or liability deriving from the
improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled
paper.
DATASENSOR S.p.A. reserves the right to make modifications
and improvements without prior notification.
826000582 Rev.C
Don’t bend the fibre-optics below,
the specified minimum bending
radius (R).
Coaxial fibres: insert the central
fibre into the emitter hole and the
peripheral fibres into the receiver
hole.
OF40
INSTRUCTION MANUAL
The fibre-optic OF40 is an accessory for
DATASENSOR LD series U.V. readers.
INSTALLATION
To install the OF40 proceed as follows:
•Disconnect the power supply of the
sensor.
•Replace the sensor lens with the fibre
adapter.
•Insert the fibre-optic into the adapter; the
first insertion resistance is due to the O-
ring seal; please continue to insert the
fibre until it reaches the mechanical
stop.
•Fix the fibre-optic to the adapter using
the setscrew wrench included in the
package.
The fibre is made of a liquid solution
enclosed in a plastic covering; for a correct
functioning of the fibre the bend radius must
be greater than 60mm; don’t twist or stretch
the fibre.
DIMENSIONS
M25x1
Ø34.5
24
44 27
5.3 66 L
44
20
Ø7
Ø10
Setscrew
Bend radius
Abutment
O-ring
Adapter
TECHNICAL DATA READING DIAGRAM
Operating temperature (fibre end fittings): -5 … +60 °C
Operating temperature (fibre body): -5 … +35 °C
Storage temperature: -5 … +60 °C
Covering material: Plastic
End fittings material: Brass Chrome plated
Bend radius: Minimum 60 mm
Protection class: IP64
Weight: 110 g.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826140002 Rev.B
0.5
mm
inch
s
pot distance
TARGET 1
TARGET 2
TARGET 3
7.5
7.5
mm inch
LD SERIES WITH OPTIC FIBRE OF-40 LENGTH = 0.5 m
15
0
15
10 20 30
10.5
0.5
OF50
INSTRUCTION MANUAL
The OF50 fibre-optic is an accessory for the
LDµluminescence detector series.
INSTALLATION
To install the OF50 proceed as follows:
•Disconnect the power supply of the
sensor.
•Replace the sensor lens with the fibre
adapter.
•Insert the fibre-optic into the adapter; the
first insertion resistance is due to the O-
ring seal; please continue to insert the
fibre until it reaches the mechanical
stop.
•Fix the fibre-optic to the adapter using
the setscrew wrench included in the
package.
The fibre is made of a liquid solution
enclosed in a plastic covering; for a correct
functioning of the fibre the bend radius must
be greater than 60mm; don’t twist or stretch
the fibre.
DIMENSIONS
1234Bend radius
5
1Lens
2Adapter
Setscrew
3
O-ring
4
Fibre-optic
5
mm
M20x0.75
63
4
520
Ø7
20
44
TECHNICAL DATA READING DIAGRAM
Operating and storage temperature: -5 … +60°C
Covering material: Plastic
Tip material: Brass Chrome plated
Adapter material: Aluminium anodized
Bend radius: Minimum 60mm
Protection class: IP64
Weight: 100 g.
WARRANTY
DATASENSOR S.p.A. warrants its products to be free from defects.
DATASENSOR S.p.A. will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date.
This warranty does not cover damage or liability deriving from the improper application of DATASENSOR products.
DATASENSOR S.p.A. Via Lavino 265
40050 Monte S. Pietro - Bologna - Italy
Tel: +39 051 6765611 Fax: +39 051 6759324
http://www.datasensor.com e-mail: info@datasensor.com
DATASENSOR S.p.A. cares for the environment: 100% recycled paper.
DATASENSOR S.p.A. reserves the right to make modifications and improvements without prior notification.
826000502 Rev.B
0.5
mm
inch
sp
ot distance
TARGET 1
TARGET 2
TARGET 3
7.5
7.5
mm inch
15
0
15
10 20 30
10.5
0.5
40
LDµSERIES WITH OPTIC FIBRE OF50 LENGTH = 0.5 m

This manual suits for next models

31

Popular Cables And Connectors manuals by other brands

Lapp Group ÖLFLEX SOLAR AL FLEX installation guide

Lapp Group

Lapp Group ÖLFLEX SOLAR AL FLEX installation guide

Festo FEC-KBG7 Assembly instructions

Festo

Festo FEC-KBG7 Assembly instructions

3M Cold Shrink QS-III Splicing Kit instructions

3M

3M Cold Shrink QS-III Splicing Kit instructions

IDEAL APP SBE 80 Series Assembly instruction

IDEAL

IDEAL APP SBE 80 Series Assembly instruction

Andor Technology ACC-ASE-06969 Technical note

Andor Technology

Andor Technology ACC-ASE-06969 Technical note

Siemens 4000A operating instructions

Siemens

Siemens 4000A operating instructions

ARX MSX48 owner's manual

ARX

ARX MSX48 owner's manual

Altinex RT300-126 user guide

Altinex

Altinex RT300-126 user guide

DEFA MiniPlug User's installation guide

DEFA

DEFA MiniPlug User's installation guide

Sanus ELM806 manual

Sanus

Sanus ELM806 manual

Cypress CLUX-16E Operation manual

Cypress

Cypress CLUX-16E Operation manual

Omron F3SN-A - instruction manual

Omron

Omron F3SN-A - instruction manual

Renesas 2368 Series user manual

Renesas

Renesas 2368 Series user manual

nvent RAYCHEM BTV Installation and maintenance manual

nvent

nvent RAYCHEM BTV Installation and maintenance manual

ULTIMATE SPEED USLK 22 B2 user manual

ULTIMATE SPEED

ULTIMATE SPEED USLK 22 B2 user manual

nVent RAYCHEM PMKG-J2LP installation instructions

nVent RAYCHEM

nVent RAYCHEM PMKG-J2LP installation instructions

Tripp Lite N352-03M Specification sheet

Tripp Lite

Tripp Lite N352-03M Specification sheet

Techno TH384 quick start guide

Techno

Techno TH384 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.