Defender DIAMOND User manual

MANUAL
DIAMOND
Read the instructions carefully before
using the machine.
Congratulations
on purchasing
a rotary machine
DIAMOND!

Specifications
Lengt
Weight
Connector
Motor
power
Voltage
Rotational
speed
Motor
Designed
Warranty and
maintenance
service
115 mm
92 g
RCA
6 V
3-10 V
10,000 rpm
Faulhaber,
Germany
in the USA
1 year

Purpose
Versatile short stroke machine
for a permanent make-up.
Compatibility
Compatible with all standard modular
cartridges.
Highly recommended using cartridges
with a membrane protecting device
from pigment leakage.
The device is compatible with standard
power equipment with an RCA cable
connection.
Working voltage: 3.5-10 V
The device not designed to operate
at higher voltages.
Short stroke: 2.5 mm
DIAMOND device is a short stroke device,
therefore, in order to avoid pigment
leakage, it is highly recommended
to adjust the needle stickout to 1-2 mm.

Complement
Device, RCA clipcord,
Friction Stabilizing O-Ring

4
3
7
1
2
5
6
1Motor Faulhaber
2Swivel holder
3Cartridge slot
4RCA slot
5RCA clip cord
6Friction Stabilizing O-Ring
7Warranty card

Maintenance instruction
1. Aach special barrier protection film
to the clipper and RCA cable (5)
2. Insert the modular needle (cartridge)
into the slot (3). To secure, turn
the cartridge clockwise until the module
snaps into place. Dierent manufacturers
of modules have various fiing dimensions,
which makes them less likely to fit
into the holder.
12
3

3. Adjust the needle stickout. It can be
adjusted by rotating the rotary holder (2).
The DIAMOND device is a short stroke
device, therefore, in order to avoid pigment
leakage, it is highly recommended to adjust
the stroke to 1-2 mm.

5. Turn on the power supply. Set the voltage
on the power supply to 3-7 V, depending
on the needle configuration and working
technique. Do not exceed the maximum
voltage of 10 V.
6. Set up device for smooth, quiet operation
by adjusting the needle stickout (2)
and voltage. All seings are individual
and depend on the power unit, application
area and work technique.
4. Connect device to the power source
using the RCA cable (4).

Do not turn the device over in the process
of work. The device is not designed for this
and will emit crackling and atypical sounds.
!
Service
Keep the device clean.
Before and after each use, remove all
possible dirt by wiping the machine
with a special disinfectant.
Remove Friction Stabilizing O-Ring every
4-6 months and apply some amount of oil
on the thread on the device. Use a special oil
for rotary or sewing machines is.
If necessary, replace the O-ring with
a new one (2 spare O-rings are supplied
with the device).
Safety
Use cartridges with a membrane protecting
device from pigment leakage. Always use
disposable sterile needles and rubber
gloves. Always use wraps or any kind
of protector on your device and RCA cable.
The manufacturer does not have
responsibility for contamination, infection
and any kind of material damage
of the customer caused by negligence
or misuse of the machine or its components.

Sterilization
In order to sterilize the device, unscrew
the holder and place it inside of an
autoclave with an ultrasonic bath or oven.
Do not store the holder in a dry oven
at temperatures higher than 100 ° Celsius
(73.15 ° Kelvin, 212 ° Fahrenheit): this will
lead to the change of colour.
Use coon pads or disposable paper towels
for this. Submerging the entire device in alcohol
or any other liquid will damage the unit and its
motor. Only the twist-o holder can be sterilized.
Do not spray or pour disinfectants
onto the device, to avoid leakage
on the motor of the device.
!
Sterilizing the entire apparatus
in an autoclave, ultrasonic bath or dry oven
will damage and malfunction its motor.
!
Holder

Warranty
Device will be covered by a 1-year warranty
from the date of purchase.
The warranty covers factory faults
and does not apply in the following cases:
The input voltage exceeded 11 V
(the maximum allowable voltage is 10 V).
The device was damaged due
to aggressive non-alcoholic antiseptics.
The device was damaged due to mechanical
damage, falling and hiing a hard surface.
The device has signs of corrosion.
The device was used for improper purposes
(i.e. not for permanent make-up
and taooing).
The device was completely immersed
in alcohol or any other liquid (except
for the twist-o holder).
The device was completely immersed
in an autoclave, oven or ultrasonic bath
(except for the twist-o holder).
The device was disassembled or underwent
self-repair (without the manufacturer's
permission).
The device or its components have been
changed.

What should I do if the machine
makes strange noises when it’s
turned over (cartridge side up)?
As with any other technology, each motor
has its functional purpose and was
designed for this purpose only. As none
of the methods of permanent make-up
involves working from the boom up,
DIAMOND device is not adapted
for such manipulations.
Please do not turn the device over
in the process of work.
!

What can I do in case
of malfunction of the device?
Send an email to service@defenderrsupply.com
with a description of the problem. Please, aach
a video to the leer in order for us to make
primary diagnostics and find a solution.
Estimated response time is 3 business days.
Keep your receipt and warranty card
for one year after purchase.
Can I get my machine repaired
after the end of the warranty
period?
You can send the device for diagnostics
and repair at your own expense. Send an email
to service@defenderrsupply.com with
a description of the problem to find out the exact
cost of the repair. For a more eicient solution
to the problem, aach a video to the leer
so we can make a primary diagnostic.
© Defenderr Co.
www.defenderrsupply.com