ironed and wait for the “iron at temperature”
light to go off.
MAINTENANCE
Limescale filter maintenance
WhentheFILTERlightcomeson,theltermust
beregeneratedorreplaced.
Toregeneratethelter,proceedasfollows:
• Turntheapplianceoffbypressing the
and buttonsorthe button(depen-
ding on the model), then unplug from the
mains.
• Removethewatertank.
• Removethelimescalelter.
• PlacetheresinlterinthelterholderJ(g.
11).(Youarerecommendedtodothisover
the kitchen sink).
• Attachthetanktotheresinlter.
• Dissolvethecontentsofthesachetofcitric
acid supplied (K)ina1litrejugoftapwa-
ter.
• Pour the resulting solution into the tank
and allow all the contents to pass through
thelter (about 20 minutes),then wait for
a minimum of 40 minutes to regenerate the
limescalelter.
• Torinsethelimescalelter,llthewatertank
with tap water and allow all the contents to
passthroughthelter.
• When the operation is completed, put the
lterandtankbackinplace.
• Plugtheapplianceintothemainsandturn
on.
• PresstheRESETbuttonto conrm the ef-
ciencyofthe lter. The FILTER light goes
off.
• Theapplianceisreadyforuse.
Please note:
Regeneratingtheresinlterguaranteesitslong-
termefciency.However,after10regenerations
(max.5yearsofuse),itshouldbereplaced.
Sachetsofcitricacidandthelimescalelterare
availablefromauthorisedcustomerservices.
Rinsing the steam generator
To optimise operation, maintain constant ste-
am production over time and save energy,
rinsethesteamgeneratorwithwateraftereve-
ry 10 ironing sessions. Proceed as follows:
• Make sure the appliance is turned off, un-
plugged from the mains and completely
cold.
• TurntheprotectivecapFon the side of the
applianceclockwiseandremoveit(g.12).
• Use a coin or screwdriver to unscrew the
steamgeneratorcap(g.12).
• Resttheapplianceonitsside(g.13)andll
withamaximumof0.7litresofwaterusing
afunneltoavoidthewaterspillingoutside
the steam generator.
• Shaketheappliancetorinsetheentiresteam
generator,thenthrowthewateraway.
• Repeattherinseprocedure.
• Screwthecapbackon,makingsureitclo-
sesthesteamgeneratorefciently.
• ReplacetheprotectivecapF.
Before resuming ironing, discharge steam
into the air for a few seconds to completely
eliminate any residues from the internal cir-
cuits.
Important!
Iftheltercannotberegeneratedorreplaced,to
continueusingtheappliancewiththeexhausted
lter,proceedasfollows:
• Useacointoturnthewaterhardnessregu-
latorLtothepositioncorrespondingtovery
hardwater(irrespectiveoftheresultsobtai-
ned using the indicator paper).
• WhentheFILTERlightcomeson,rinsethe
steamgeneratorasdescribedabove.
• Afterrinsing,presstheRESETbutton.
Thefrequentrinsingwillavoidlimescalebuilding
up in the steam generator.
CLEANING
• Thesurfaceoftheplatemustbekeptclean.
To clean, just wipe the cold surface with a
damp cloth.
• Theironmustneverbetreatedwithdesca-
ling products.
AFTER IRONING
Afternishing ironing, you shouldput the iro-
ning system away with the door tightly closed
toavoiddustandforeignbodiesfallingintothe
tankandpossiblyjeopardisingoperationofthe
pump.