manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Delta
  6. •
  7. Fan
  8. •
  9. Delta breez Slim SLM80-110-C User manual

Delta breez Slim SLM80-110-C User manual

INSTALLATION AND OPERATING INSTRUCTIONS
CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is
AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the National Electrical Code (NEC) and the
Occupational Safety and Health Act (OSH Act).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are congured as
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL Listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
1. For General Ventilating Use Only. Do Not Use To
Exhaust Hazardous Or Explosive Materials And
Vapors.
2. Not for use in cooking area. (Fig. B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan
at least 8.2 feet (2.5m) above the oor.
WARNING
CAUTION
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
2. Before servicing or cleaning unit, switch power o at
the service panel and lock the service disconnecting
means to prevent the power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done
by a qualied person(s) in accordance with all
applicable codes and standards, including re-rated
construction.
4. Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow
the heating equipment manufacturer’s guideline and
safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society of Heating, Refrigerating and
Air-Conditioning Engineers (ASHRAE) and local code
authorities.
5. When cutting or drilling into the wall or ceiling, do not
damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application
and be connected to a GFCI (Ground Fault Circuit
Interrupter) –protected branch circuit.
8. Do not use this unit with any other solid-state control
device. Solid-state control device may cause
harmonic distortion, which can cause a motor
humming noise. (Avertissement: ne convient pas à
des régulateurs de vitesse à semi-conducteurs).
9. NEVER place a switch where it can be reached from a
tub or shower.
10. Not to be installed in a ceiling thermally insulated to a
value greater than R50. (This is required for
installation in Canada only).
11. Do not open/disassemble LED light engine.
WARNING: Turn off electricity at breaker box before
beginning installation.
1. Carefully remove unit from carton.
2. Check area above installation location to be sure that
wiring can run to the planned location and that duct
work can be run. Make sure the area is sucient for
proper ventilation.
3. Inspect duct work and wiring before proceeding with
installation.
4. Before installation, provide inspection and future
maintenance access at a location that will not
interfere with installation work.
5. You may need the help of a second person to install
this fan: one person on the attic side and one on the
room side.
Note: Installations may vary depending on how the
previous bath fan was installed. Supplies necessary for the
installation of your bath fan are not all included. However,
most are available at your local home improvement or
hardware store.
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
Fig. A
45°
45°
floor
Fig. B
Cooking
Equipment
Cooking area
Do not install above or
inside this area
PACKAGE CONTENTS
For Models:
Part name Appearance Quantity
Fan Body
Machine Screw
(M4x6 mm)
Tapping Screw
(Ø4×25mm)
1
6
1
Machine Screw
(#8-32x5/16”) 1
Wiring Cover 1
Hanger Bar 1
For the Model of SLM80-110-C, SLM80-110D-C
Part name Appearance Quantity
Grille 1
For the Model of SLM80-110LED-C, SLM80-110DLED-C
Part name Appearance Quantity
Grille 1
Roof cap
(with built-in
damper)
Seal gap
around
housing Caulk termination
to duct
Fan housing
Short piece of flexible
duct helps alignment
and absorbs sound
or
2~3 ft
straight run
before elbow
Wall cap
(with built-in
damper)
Wall cap
(with built-in
damper)
MODELS: SLM80-110-C, SLM80-110D-C, SLM80-110LED-C, SLM80-110DLED-C
Proper insulation around the fan to minimize building heat
loss and gain. The ducting from this fan to the outside of
the building has a strong eect on the air ow, noise and
energy use of the fan. Use the shortest, straightest duct
routing possible for best performance, and avoid installing
the fan with smaller ducts than recommended. Insulation
around the ducts can reduce energy loss and inhibit mold
growth. Fans installed with existing ducts may not achieve
their rated air ow.
1. The fan will operate most eciently when located
where the shortest possible duct run and minimum
number of elbows will be needed.
2. Use a roof cap or wall cap that has a built-in damper
to reduce backdrafts.
3. External timer can be used in conjunction with
single-speed mode only, please contact Delta Breez
customer service and consult with a licensed
electrician for compatibility.
4. External dimmer can be used in conjunction with LED
light model, please contact Delta Breez customer service
and consult with a licensed electrician for compatibility.
ASSEMBLY INSTRUCTION
Page 1.
ASSEMBLY INSTRUCTION
Installation I
(Ceiling/Wall mount housing with flange)
Installation II
(Using suspension bracket):
1.
To bend the housing tabs out to 90 degree and make
housing tabs contact the bottom or front of the joist.
1. The housing mounts with 4 screws (Ø4×25 mm).
Screw housing to joist through the round holes in
each mounting ange, then through the other holes.
2. Insert suspension bracket into the channel on
housing.
2. The housing mounts with 4 screws (Ø4×25 mm).
Screw housing to joist through the round holes in
each mounting ange, then through the other holes.
Joist
Tabs
Joist
Tabs
Joist
Screw Ø4x25 mm
Joist
Screws Ø4x25 mm
WIRING DIAGRAM
1. SLM80-110-C
CONNECT WIRING
Page 2.
POWER SWITCH
JUNCTION BOX SWITCH BOX
WHITE
BLACK OFF
ON
GREEN GRD
L
N
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WIRING
PLATE
BLACK
WHITE
GROUND
(bare)
POWER
SWITCH
Installation III (Retrofit installation):
1. Removing existing fan.
2. Measure the ceiling or wall opening and cut a new
opening to ensure it is large enough to accommodate
the new fan (10 3/4 in. x 11 1/2 in. suggested).
A piece of wood (not provided) may be necessary that
is screwed in from indoor through the ceiling board
or wall. Suggested size is H 4 in. x L 17 in. Position the
screws far enough from the edge of the ceiling board
or wall that it does not crumble and give way.
4. Using wire nuts (not provided) connect house wires
to fan wires as shown in “CONNECT WIRING” diagram
A. Insert housing into ceiling or wall opening and
secure housing by using tapping screws (ø 4x25 mm).
3. Remove the fan body by release four machine screws
(M4 x 45 mm), unplug all connectors from wiring
panel and then remove duct connector by release
machine screw (M4 x 6 mm).
Wood
4“
17“
11 1/2“
10 3/4“
Screw M4 x 45mm
Screw M4 x 6mm
CEILING MOUNTING
Screw Ø4×25mm
MODELS: SLM80-110-C, SLM80-110D-C, SLM80-110LED-C, SLM80-110DLED-C
Open Hole
DUCT CONNECTION
Connection method for 4” oval duct connector
1. Insert the duct into the duct connector and tape all
ductworks connection to make them secure and air
tight.
2. Install the duct with a gradient 1°~2° to the outside.
WALL MOUNTING
Screw Ø4×25mm
5. Do the duct work as below picture and follow “DUCT
CONNECTION” and then x the duct connector to the
housing inside by using machine screw (M4 x 6 mm).
Pull existing duct into housing
Screw M4 x 6mm
Insert tab into hole in housing
Screw M4 x 45mm
6. Insert fan body into housing by using four machine
screws (M4 x 45 mm) originally on the fan body and
plug in all connectors.
Connection method for 3” round duct connector
3. 4” Oval to 3” round duct adapter, VFRU-29-10DA
(sold separately).
4. Please follow step “1” and “2” to install.
Tape
VFRU-29-10DA
(sold separately)
Duct Connector
Grille
Body
Outside
Inside
Gradient
1°~2°
Tape
Duct
Ceiling
2. SLM80-110D-C
JUNCTION BOX SWITCH BOX
HI
POWER SWITCH
MODE SWITCH
WHITE
BLACK OFF
ON
BLUE
GRD
L
N
L
N
GREEN
WHITE
BLACK
ON/OFF SWITCH
(purchase separately) SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
MODE
SWITCH
BLUE
Screws Ø4x25 mm
Suspension Bracket
Channel
Screw Ø4×25mm
Joist
Joist
Bottom Of Joist
Screw #8-32x5/16”
3.
Extend suspension bracket to the width of the joists.
Make sure the fan body is level and perpendicular
with the joist, and ush with ceiling surface.
4. Fasten suspension bracket to joist with tapping
screws (ø 4×25 mm).
5. Secure suspension bracket to housing with screw
(#8-32x5/16”). TURN OFF POWER SOURCE.
REVIEW ALL SAFETY PRECAUTION.
1. Follow all local electrical and safety codes,
ANSI/NFPA70.
2. NEVER place a switch where it can be reached
from a tub or shower.
3. Use wire nuts (not provided) and connect house
power cable to ventilating fan as below diagram.
4. 14 AWG (2.1 mm) is the smallest conductor that
shall be used for branch-circuit wiring.
5. Use slotted screwdriver to remove a hole on
wiring cover (from parts bag).
6. Push all wires into wiring compartment of units,
use screw(from parts bag) to secure wiring cover to
housing.
OPERATION
Single Speed Models:
SLM80-110-C, SLM80-110LED-C
Dual Speed Models:
SLM80-110D-C, SLM80-110DLED-C
1.
Turn the POWER switch on to operate at user
adjustable full speed airow - the LED indicator will
be green.
JUNCTION BOX SWITCH BOX
SWITCH
WHITE
BLACK
RED
GRD
N
L
N
GREEN
WHITE
OFF
ON
BLACK
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
RED
ON/OFF SWITCH
(purchase separately)
6. SLM80-110LED-C
Combine power & light to one switch.
•Switch ON : Fan runs at user adjustable full speed
airow and the light on at the same time.
ON
WHITE
BLACK
BLUE
GREEN GRD
N
N
RED
N
WHITE
WHITE
L
OFF
SWITCH
JUNCTION BOX SWITCH BOX
BLACK
GROUND
(bare)
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
WIRING
PLATE
RED
BLUE
7. SLM80-110DLED-C
Hardwire power and combine mode & light to one switch.
•Switch OFF: Fan runs 24 hours at “Low speed control
mode”.
•Switch ON: Fan runs “Full speed control mode” and
light on at the same time.
OTHER WIRING OPTION
See OPERATION section for detail description of “mode”.
5. SLM80-110D-C
Hardwire power.
•Switch OFF: Fan runs 24 hours at “Low speed control
mode”.
•Switch ON : Fan runs at user adjustable full speed
airow.
ON
SWITCH
WHITE
BLACK
BLUE
GRD
N
L
N
GREEN
WHITE
OFF
JUNCTION BOX SWITCH BOX
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
WIRING
PLATE
BLUE
3. SLM80-110LED-C
4. SLM80-110DLED-C
HI
POWER SWITCH
MODE SWITCH
WHITE
BLACK OFF
OFF
ON
BLUE
GREEN GRD
L
N
L
N
ON
LIGHT SWITCH
RED L
N
WHITE
WHITE
JUNCTION BOX SWITCH BOX
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
MODE
SWITCH
LIGHT
SWITCH
RED
BLUE
MODELS: SLM80-110-C, SLM80-110D-C, SLM80-110LED-C, SLM80-110DLED-C
Page 3.
Lighting Connector
Slots
LED indicator
Full speed air volume
preset control, 80 or 110 CFM
Delay time control
LED indicator
Full speed air volume preset control
Low speed air volume preset control
110
80
HVI LABEL
50
LOW SPEED
CFM
0.5
45
15
5
TIME (min)
80
30
60
JUNCTION BOX SWITCH BOX
POWER SWITCH
LIGHT SWITCH
WHITE
BLACK OFF
ON
OFF
ON
RED
GRD
L
N
L
N
GREEN
WHITE
BLACK
ON/OFF SWITCH
(purchase separately)
SWITCH BOX
120 VAC
LINE IN
WHITE
GROUND
(bare)
POWER
SWITCH
WIRING
PLATE
LIGHT
SWITCH
RED
GRILLE INSTALLATION
1.
LED Models :
(only SLM80-110LED-C and SLM80-110DLED-C)
Insert the LED lighting connector into the power
socket of main body.
2.
All Models :
Insert the mounting springs into the slots and mount
the grille to the fan body.
CARE AND MAINTENANCE
TURN OFF POWER SOURCE. REVIEW ALL SAFETY
PRECAUTION.
See safety information before proceeding. Routine
maintenance should be done at least once a year.
•
Never use solvents, thinner or harsh chemicals when
cleaning the fan.
•
Do not allow water to enter the motor.
•
Do not immerse metal parts in water.
•
Do not immerse resin parts in water over 140º F.
1. To remove grille, squeeze springs and pull down.
Wash and clean grille with non-abrasive kitchen
detergent. Then wipe dry with a new cloth.
2. Remove dust and dirt from the fan body with a
vacuum cleaner.
3. Using a cloth dampened with non-abrasive kitchen
detergent, remove dust and dirt from the fan body.
Then wipe dry with new cloth.
4. Replace the grille back onto the fan body. Turn on fan
switch to operate fan again.
2.
Low speed control mode: Turn the POWER switch on
(MODE switch is o) to operate at the user-adjustable
low speed airow - the LED will be green
3. Full speed control mode: Turn the POWER switch &
MODE switch on to operate at user-adjustable full
speed mode - the LED indicator will be amber. When
the user turns the MODE switch o, the fan will
continue to run at the full speed until the user-adjust-
able time delay has elapsed, and then will
automatically change to the user-adjustable low
speed airow. The LED indicator will be green.
Factory setting: High speed airow 110CFM, low speed
airow 50CFM, time delay 5 minutes.
Vaccum
Cleaner
1.
3.
2.
4.
MODELS: SLM80-110-C, SLM80-110D-C, SLM80-110LED-C, SLM80-110DLED-C
Page 4.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants
to the original consumer purchaser in the USA and
Canada that the Breez ventilation fan products will
be free from defects in material or workmanship.
This warranty is limited to three (3) years from the
original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for
any defective product will be supplied free of
charge for installation by the consumer. The
warranty provided herein does not cover charges
for labor or other costs incurred in the trouble-
shooting, repair, removal, and installation service.
2. All returns of defective parts or products must
include the product model number, and must be
made through an authorized Delta Electronics
distributor. Authorized returns must be shipped
prepaid. Repaired or replacement products will
be shipped by Delta Electronics F.O.B. shipping
point.
3. Delta Electronics shall not be liable for any
indirect, incidental, consequential, punitive, or
special damages arising out of or in connection
with products use or performance, regardless of
the form of action whether in contract, tort
(including negligence), strict product liability or
otherwise.
4. The warranty does not cover if user does not
comply with manufacturer’s installation manual.
5. To qualify for warranty service, you must notify
Delta Electronics at the address or telephone
number below.
6. Delta Electronics shall have no liability to the
original owner-user with respect to any defect
caused by abuse, misuse, neglect, improper
transportation or storage, improper testing,
improper installation, improper operation,
improper use, improper maintenance, improper
repair, improper alteration, improper modica-
tion, tampering or accident of products or parts
thereof, or unusual deterioration or degradation
of products or parts thereof due to a physical
environment beyond the requirements of
products’ specications.
Address:
46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number:
1-888-979-9889 - Technical Support
1-877-685-4384 - Customer Sales Support
www.deltabreez.com
TROUBLE SHOOTING
DIMENSIONS
SPECIFICATIONS
Note: Specications subject to change without notice.
The fan is not turning on 1. Power o
2. Faulty switch
3. Faulty wire connection
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
The fan seems louder than it
should
1. CFM too great
2. Damper not working properly
or damaged
3. Bend in duct too close to fan
discharge
4. Fan discharge reduced to t
smaller duct
5. Fan body not securely attached
1. Be sure the CFM rating on the fan matches
the size of your room.
2. Check damper to ensure it is opening and
closing properly. If the damper has become
damaged, please call Customer Service.
3. Be sure you do not have any sharp bends in
duct closer than 18 in. to the fan discharge.
4. Use recommended size ducting to reduce
fan noise.
5. Be sure the fan is securely attached to your
ceiling joists.
The fan is not clearing the
room
1. Insucient intake airow within
room
2. Insucient CFM
1. Be sure a door or window is slightly ajar or
opened to allow airow. The fan is not able
to draw air out of the room without enough
airow to draw in from.
2. Be sure the CFM rating on the fan matches
the requirements for your room size.
The light is not turning ON 1. Power o
2. Faulty switch
3. Faulty wire connection
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
SLM80-110-C, SLM80-110D-C SLM80-110LED-C, SLM80-110DLED-C
13"
13"
13"
13"
10
12"
11
14"
4"
4"Oval Duct
Model No. Voltage
(V)
Frequency
(Hz)
Air Flow
@ 0.1SP
(CFM)
Power
@ 0.1SP
(W)
Weight Note Light Spec
SLM80-110-C
SLM80-110D-C
SLM80-110LED-C
SLM80-110DLED-C
120 60 110 16.5 8.2 Single
Speed -
120 60 110 16.5 8.2 Dual
Speed -
120 60 110 16.5 8.6 Single
speed
13Watts,
850Lumens,
3000K, CRI90
120 60 110 16.5 8.6 Dual
Speed
13Watts,
850Lumens,
3000K, CRI90

This manual suits for next models

3

Other Delta Fan manuals

Delta Breez GreenBuilder VFB080C4A1 User manual

Delta

Delta Breez GreenBuilder VFB080C4A1 User manual

Delta SIG80L User manual

Delta

Delta SIG80L User manual

Delta breez integrity ITG80RLED-ADJ User manual

Delta

Delta breez integrity ITG80RLED-ADJ User manual

Delta BreezRadiance RAD110LED User manual

Delta

Delta BreezRadiance RAD110LED User manual

Delta NFB1212H User manual

Delta

Delta NFB1212H User manual

Delta HEF070A Series User manual

Delta

Delta HEF070A Series User manual

Delta Breez GreenBuilder GBR100H User manual

Delta

Delta Breez GreenBuilder GBR100H User manual

Delta Breez 150F User manual

Delta

Delta Breez 150F User manual

Delta breez 70F-ELED User manual

Delta

Delta breez 70F-ELED User manual

Delta breez GreenBuilder GBR80LED User manual

Delta

Delta breez GreenBuilder GBR80LED User manual

Delta breez GBR80H User manual

Delta

Delta breez GBR80H User manual

Delta BREEZ 90LED-REC-ADJ User manual

Delta

Delta BREEZ 90LED-REC-ADJ User manual

Delta breez SMT130 User manual

Delta

Delta breez SMT130 User manual

Delta BreezSlim SLM50-110-C User manual

Delta

Delta BreezSlim SLM50-110-C User manual

Delta SH-FT02 User manual

Delta

Delta SH-FT02 User manual

Delta KFB1724EHS User manual

Delta

Delta KFB1724EHS User manual

Delta VFB080C4L1 User manual

Delta

Delta VFB080C4L1 User manual

Delta Breez Slim SLM70ELED User manual

Delta

Delta Breez Slim SLM70ELED User manual

Delta VFB080C4A1 User manual

Delta

Delta VFB080C4A1 User manual

Delta KHB1248EHS User manual

Delta

Delta KHB1248EHS User manual

Delta GBR100L User manual

Delta

Delta GBR100L User manual

Delta Breez Slim SLM80-110 User manual

Delta

Delta Breez Slim SLM80-110 User manual

Delta Breez ITG50 User manual

Delta

Delta Breez ITG50 User manual

Delta LFB0712H User manual

Delta

Delta LFB0712H User manual

Popular Fan manuals by other brands

Craftmade Fresco FR52 Specifications

Craftmade

Craftmade Fresco FR52 Specifications

Levoit Classic 36-Inch user manual

Levoit

Levoit Classic 36-Inch user manual

SEVERIN VL 8632 - Dimensions

SEVERIN

SEVERIN VL 8632 - Dimensions

Mitsubishi Electric VL-50SR2-E installation manual

Mitsubishi Electric

Mitsubishi Electric VL-50SR2-E installation manual

S&P decor-100 DC manual

S&P

S&P decor-100 DC manual

Craftmade K52 Specifications

Craftmade

Craftmade K52 Specifications

Miele DA 398-5 Operating and installation instructions

Miele

Miele DA 398-5 Operating and installation instructions

Matsui MSF403WM Instruction book

Matsui

Matsui MSF403WM Instruction book

Modern Forms FH-W1811-5-GH/WG installation instructions

Modern Forms

Modern Forms FH-W1811-5-GH/WG installation instructions

Rotel U740CH1 Instructions for use

Rotel

Rotel U740CH1 Instructions for use

Modine Manufacturing ECO MIC Technical manual

Modine Manufacturing

Modine Manufacturing ECO MIC Technical manual

Vortice PUNTO VORTICE Series Instruction booklet

Vortice

Vortice PUNTO VORTICE Series Instruction booklet

Bimar CICLONE VB30 Instruction booklet

Bimar

Bimar CICLONE VB30 Instruction booklet

Fanimation The Beckwith FP7964 Series owner's manual

Fanimation

Fanimation The Beckwith FP7964 Series owner's manual

Ruck Ventilatoren KVR 30 Series Assembly instruction

Ruck Ventilatoren

Ruck Ventilatoren KVR 30 Series Assembly instruction

SPT SF-16W90 owner's manual

SPT

SPT SF-16W90 owner's manual

enervent Salla eWind Operating and maintenance instructions

enervent

enervent Salla eWind Operating and maintenance instructions

Trotec TVE 40 T Original instructions

Trotec

Trotec TVE 40 T Original instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.