manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Delta
  6. •
  7. Fan
  8. •
  9. Delta breez slim SLM70 User manual

Delta breez slim SLM70 User manual

CEILING/WALL VENTILATION FAN
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION
1. Make sure that the electric service supply voltage is
AC 120V, 60Hz.
2. Follow all local electrical and safety codes, as well as
the Nation Electrical Code (NEC) and the Occupation
Safety and Health Act (OSH Act).
3. Always disconnect the power source before working
on or near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease,
hot surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are congured as
shown in Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower
when installed in a GFCI protected branch circuit.
9. These ventilating fans are intended for residential
usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Turning angle too large Duct shrink
Too many elbows Elbow near the body
Body
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
45
Cooking are a
45
Do not in s tall above or
inside this area
Cooking
Equipm entfloor
SUPPLIED ACCESSORIES
Fig. A
Fig. B
1. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact
the manufacturer.
2.
3. Installation work and electrical wiring must be
done by qualied person(s) in accordance with
all applicable codes and standards, including
re -rated construction.
4.
5. When cutting or drilling into walls or ceiling s, do
not damage electrical wiring and other hidden
utilities.
6.
7.
Ducted ventilating fans must always be vented to
the outdoors.
8.
If this unit is to be installed over a tub or shower, it
must be marked as appropriate for the application
and be connected to a GFCI (Ground Fault Circuit
Interrupter)-protected branch circuit.
3.
4.
This product must be properly grounded
Part name Appearance Quantity
Grille
1
Fan
1
Housing
1
Duct
1
Screw
(M4x12) 3
DIMENSIONS
SPECIFICATIONS
Note: Design and specications subject to change
without notice.
OPERATION
1. Single Speed Model: SLM50
2. Single Speed Model: SLM70
Model No. Voltage
(V)
Frequency
(Hz)
Power
(W)
Air Flow
@ 0.1SP
(CFM)
Weight
(lb.) Note
SLM50 120 60 6.5 50 3.65 Single
Speed
SLM70 120 60 13.2 70 3.65
Single
Speed
MAINTENANCE WARNING:
Disconnect the power source before working on the unit.
Routine maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other
such chemicals for cleaning the ventilating fan.
2. Do not allow water to enter the motor.
3. Do not soak resin parts in water over 60°C (140°F) .
CLEANING
1. Pull down the spring to remove the grille.
2. Wash and clean the grille. (Use non-abrasive
kitchen de tergent, wipe dry with a new cloth.)
3. Remove dust and dirt from the ventilating fan
using a vacuum cleaner.
4. Using a cloth dampened with kitchen detergent,
remove any dirt from ventilating fan. Wipe dry
with a new cloth.
5. Replace the grille.
Before servicing or cleaning the unit, switch the
power o at the service panel and lock the service
disconnecting means to prevent the power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag,
to the service panel.
Single speed control mode: Turn the power
switch to operate ON/OFF. The LED indicator will
be green.
Single speed control mode: Turn the power
switch to operate ON/OFF. The LED indicator will
be green.
To reduce the risk of injury to persons, install the
fan at least 7 feet (2.1m) above the oor.
Sucient air is needed for proper combustion and
exhausting of gases through the ue (chimney) of
fuel burning equipment to prevent back drafting.
Follow the heating equipment manufacturer’s
guideline and safety standards such as those
published by the National Fire Protection
Association (NFPA), and the American Society for
Heating Refrigeration and Air Conditioning
Engineers (ASHRAE) and the local code authorities.
Do not use this unit with any other solid-state
control device. Solid-state controls devices may
cause harmonic distortion, which can cause a
motor humming noise.
10. Not to be installed in a ceiling thermally insulated
to a value greater than R50. (This is required for
installation in Canada only).
9. NEVER place a switch where it can be reached
from a tub or shower.
INSTALLATION AND OPERATING INSTRUCTIONS
Page 1.
MODELS SLM50 / SLM70
Proper insulation around the fan to minimize building
heat loss and gain.
Page 2.
MODELS SLM50 / SLM70
INSTALLATIONS
Install with wood frame
Model No. SLM50 SLM70
Install Dim.
(Inch) 7.5X7.25 7.5X7.25
1. Remove the motor plate from the housing by
removing the three screws. (Fig. C)
2. Remove the wiring cover from the housing by
pulling straight out. Choose a hole and use a
slotted screwdriver to remove it. (Fig. D)
3. Follow all local electrical and safety codes.
NEVER place a switch where it can be reached
from a tub or shower. Connect wires as shown in
wiring diagrams. (Fig. E)
4. Using wire nuts , connect the house power cable
to the ventilating fan wires. 14 AWG (2.1 mm 2) is
the smallest conductor that shall be used for
branch-circuit wiring. (Fig. F)
5. Insert the duct into the duct connector and tape
all ductwork connection s to make them secure
and air tight. Install the duct with a gradient 1°~2°
to the outside. (Fig. G)
6. New installation prior to nishing the ceiling
or wall: Insert the fan between joists. Make sure
the fan body is level and perpendicular with the
joist. (Fig. H)
7. Replacement installation: After making
electrical and ductwork connections (see steps 2~5),
nail the housing in place. Drive nails through the
housing w here indicated by arrows.
(Fig. I)
8. New installation in an existing ceiling or wall:
Bend tabs outward 90°(Use a screw driver if desired)
and position housing so that tabs rest against
the bottom edge of the joists (or front of stud). Nail
the housing to the joist or stud using four nails to
ensure a solid, quiet installation. Ceiling installations:
Tabs on the opposite side of the housing can be
bent outward to rest on top of 1/2" ceiling material
and provide extra stability. (Fig. J)
9. Plug in the motor and lock the fan body back by
using three screws. (Fig. C)
10. Squeeze the grille springs together and insert the
springs into the slots in the motor plate. Push the
grille up against the ceiling or wall. When the
power is on, check for abnormal vibrations or
sounds. Insert the mounting springs into the slots
and mount the grille to the body. (Fig. K)
(Fig. C)
Open chosen hole
(Fig. D)
(Fig. C)
Receptacle
Plug
connector
Fig. E
O
On
Fig. F
Fig. G
Wire nut
Power cable
Compartment
Ventilation Fan
Black
White
Green
Switch Box
(Purchase Separately)
Live
Neutral
Ground
Fig. H Fig. H
Tapping screw
Fig. H
Fig. I
Fig. J
Fig. K
Nail
Stud
Tabs
WARRANTY
DELTA ELECTRONICS THREE YEARS
LIMITTED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the
original consumer purchaser in the USA and Canada that
the Breez ventilation fan products will be free from defects
in material or workmanship. This warranty is limited to
three (3) years from the original date of purchase.
Limitations and Exclusions
During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other costs
incurred in the troubleshooting, repair, removal, and
installation service.
All returns of defective parts or products must
include the product model number, and must be
made through an authorized Delta Electronics
distributor. Authorized returns must be shipped
prepaid. Repaired or replacement products will be
shipped by Delta Electronics F.O.B. shipping point.
Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special damages
arising out of or in connection with products use or
performance, regardless of the form of action
whether in contract, tort (including negligence), strict
product liability or otherwise.
This warranty does not extend to uorescent lamp
starters and tubes.
The warranty does not cover if user does not comply with
manufacture’s installation manual.
To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by abuse,
misuse, neglect, improper transportation or storage,
improper testing, improper installation, improper
operation, improper use, improper maintenance,
improper repair, improper alteration, improper
modication, tampering or accident of products or parts
thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment
beyond the requirements of products’ specications.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889

This manual suits for next models

4

Other Delta Fan manuals

Delta KHB1248EHS User manual

Delta

Delta KHB1248EHS User manual

Delta Breez GreenBuilder GBR50 User manual

Delta

Delta Breez GreenBuilder GBR50 User manual

Delta ITG70BT User manual

Delta

Delta ITG70BT User manual

Delta breez RAD80-DGL User manual

Delta

Delta breez RAD80-DGL User manual

Delta Breez GreenBuilder VFB080C4A1 User manual

Delta

Delta Breez GreenBuilder VFB080C4A1 User manual

Delta SH-FT02 User manual

Delta

Delta SH-FT02 User manual

Delta BreezIntegrity ITG100RLED User manual

Delta

Delta BreezIntegrity ITG100RLED User manual

Delta GBR100 User manual

Delta

Delta GBR100 User manual

Delta BreezSlim SLM70-LVDC User manual

Delta

Delta BreezSlim SLM70-LVDC User manual

Delta breez 110LED-ADJ User manual

Delta

Delta breez 110LED-ADJ User manual

Delta breez SMT150LED User manual

Delta

Delta breez SMT150LED User manual

Delta breez Slim SLM80-110-C User manual

Delta

Delta breez Slim SLM80-110-C User manual

Delta AirEye Ion User manual

Delta

Delta AirEye Ion User manual

Delta KFB1724EHS User manual

Delta

Delta KFB1724EHS User manual

Delta BreezSlim SLM50-110-C User manual

Delta

Delta BreezSlim SLM50-110-C User manual

Delta VFB25ADBT User manual

Delta

Delta VFB25ADBT User manual

Delta Breez 150F User manual

Delta

Delta Breez 150F User manual

Delta breez REC80LED User manual

Delta

Delta breez REC80LED User manual

Delta breez integrity ITG80RLED-ADJ User manual

Delta

Delta breez integrity ITG80RLED-ADJ User manual

Delta LFB0712H User manual

Delta

Delta LFB0712H User manual

Delta RAD80L User manual

Delta

Delta RAD80L User manual

Delta Breez GreenBuilder GBR100H User manual

Delta

Delta Breez GreenBuilder GBR100H User manual

Delta VFB24ACTH User manual

Delta

Delta VFB24ACTH User manual

Delta QFR0612DH-B User manual

Delta

Delta QFR0612DH-B User manual

Popular Fan manuals by other brands

TriangleTube GPX Series Installation, Operation & Repair Parts Information

TriangleTube

TriangleTube GPX Series Installation, Operation & Repair Parts Information

Pro-Elec PEL01935 instructions

Pro-Elec

Pro-Elec PEL01935 instructions

Awenta Orbit WXO100R instruction manual

Awenta

Awenta Orbit WXO100R instruction manual

Zicooler Suitable UML-018 instruction manual

Zicooler

Zicooler Suitable UML-018 instruction manual

Lasko S08600 operating manual

Lasko

Lasko S08600 operating manual

UNITED USF-613 instruction manual

UNITED

UNITED USF-613 instruction manual

Monte Carlo Fan Company 3BWR50XXD Series Fan Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3BWR50XXD Series Fan Owner's guide and installation manual

Harbor Breeze 872 manual

Harbor Breeze

Harbor Breeze 872 manual

Rotheigner Air Premium 100 manual

Rotheigner

Rotheigner Air Premium 100 manual

Faro Barcelona 33466 manual

Faro Barcelona

Faro Barcelona 33466 manual

iGenix IGFD6035W user manual

iGenix

iGenix IGFD6035W user manual

Faro Barcelona andros installation guide

Faro Barcelona

Faro Barcelona andros installation guide

Price VKD Series manual

Price

Price VKD Series manual

Sefa MOTORDOR 12C quick start guide

Sefa

Sefa MOTORDOR 12C quick start guide

Ebmpapst W2E200-HH86-01 operating instructions

Ebmpapst

Ebmpapst W2E200-HH86-01 operating instructions

HiB SELV Hush Chrome Fitting instructions

HiB

HiB SELV Hush Chrome Fitting instructions

emerio FN-111537 instruction manual

emerio

emerio FN-111537 instruction manual

Vortice NORDIK EVOLUTION R Instruction booklet

Vortice

Vortice NORDIK EVOLUTION R Instruction booklet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.