DOP
-107BV
Instruction Sheet
(1) General precautions
Thank you for purchasing this product. This instruction sheet provides information about the DOP-100
series HMI. Before using this product, please read through this instruction sheet carefully to ensure the
correct use of the product. Please keep this sheet handy for quick reference whenever needed. Before
finishing reading this sheet, please follow the instructions below:
 Install the product in an indoor location, which is free of vapor, corrosive and inflammable gas and
liquids.
 Please refer to the wiring diagram when connecting the wires.
 Ensure your HMI is correctly grounded. The grounding method must comply with the national
electrical standard (please refer to NFPA 70: National Electrical Code, 2005 Ed.).
 Do not disassemble the HMI or change the wiring when power is on.
 Do not touch the power supply when power is on, or it may cause electric shock.
 When the HMI displays a low power notification and requires a battery change, please contact
your local distributor or Delta Customer Service Center for the replacement. Do not change the
batteries by yourself.
 This product can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.
 Cleaning method: please use a dry cloth to clean the product.
 This product must be used at an altitude below 2,000 m.
 If the equipment is used in a manner not specified by the manufacturer, the protection provided by
the equipment may be impaired.
 For repair and maintenance, please contact Delta Electronics, Inc. Address: No.18, Xinglong Rd.,
Taoyuan City, Taiwan. TEL: +886-3-3626301.
If you have any inquiry during operation, please contact our local distributors or Delta sales
representatives. The content of this instruction sheet may be revised without prior notice. Please consult
our distributors or download the latest version at Delta’s website (http://www.delta.com.tw/ia).
(2) Communication port pin assignment
DOP-107BV COM1
COM Port Pin
MODE1 MODE2 MODE3
COM1 COM2 COM1 COM2 COM1 COM2
RS-232 RS-485 RS-485 RS-485 RS-232 RS-422
1 - - D+ - - TXD+
2 RXD - - - RXD -
3 TXD - - - TXD -
4 - D+ - D+ - RXD+
5 GND GND GND
6 - - D- - - TXD-
7 RTS - - - RTS -
8 CTS - - - CTS -
9 - D- - D- - RXD-
Note: mark “-” means connection is not required.
(3) Description of each part
DOP-107BV (front view)
AOperation / display area
DOP-107BV (rear view)
A USB Slave B USB Host
C Power input terminal
(24 AWG wire min.) D COM1
(4) Mounting dimensions
DOP-107BV
Unit: mm (inch)
Operation temperature: 0oC to 50oC (32oF to 122oF)
Storage temperature: -20oC to 60oC (-4oF to 140oF)
(5) Installation and wiring
Precautions:
 Incorrect installation direction may result in malfunction.
 To ensure the HMI is well ventilated, make sure there is sufficient space between the HMI and the
adjacent objects or walls.
 This product should be used on a case / platform which conforms to enclosure Type 4X standard (for
indoor use only).
 The maximum panel thickness for mounting must be no greater than 5 mm.
 Copper conductor only.
Installation steps:
Step 1:
Put the waterproof gasket into the HMI and then
insert the HMI into the panel cutout.
Step 2:
Place the fasteners into the slots and tighten the
screws until reaching the panel cutouts.
Step 3:
Tighten the screws with the torque less than
0.5 N-M / 0.7 N-M to avoid damage to the plastic
case.
DOP-107BV torque: 6.17 lb-inch (0.7 N-M)
Step 4:
For heat dissipation, please keep a minimum
clearance of 60 mm on the rear of the HMI.
Wiring:
Type Wire gauge (AWG) Stripped length Torque
Solid 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
Stranded 24 - 12 7 - 8 mm 5 kg-cm (4.3 lb-in)
Please refer to the following diagram when wiring the power connector. The temperature
rating of the cable must be greater than 75°C (167°F).
(6) Hardware specifications
Model DOP-107BV
Display
Panel type 7" TFT LCD (65535 colors)
Resolution 800 x 480 pixels
Backlight LED backlight (half-life under room temperature 25oC > 20,000 hours)*1
Display range 154.08 mm * 85.92 mm
Brightness 400 cd / m² (Typ.)
CPU ARM Cortex-A8 (800 MHz)
Flash ROM 256 Mbytes
RAM 256 Mbytes
Touchscreen 4-wire resistive touchscreen > 1,000,000 operated
Buzzer Multi-tone frequency (2 K – 4 KHz) / 80 dB
Network interface N/A
USB 1 USB Slave Ver 2.0; 1 USB Host Ver 2.0
SD N/A
Serial
communication
port
COM1 RS-232 (supporting flow control) / RS-485*2
COM2 RS-422 / RS-485*2
COM3 N/A
Auxiliary function key N/A
Calendar Built-in
Cooling method Natural cooling
Approvals CE / UL (please use shielding network cable and magnetic ring with the filter of
300 ohm / 100 MHz)
Panel waterproof level IP65 / NEMA4 / UL TYPE 4X (indoor use only)
Operation voltage*2 DC +24V (-15% to +15%) (please use an isolated power supply)
Supplied by Class 2 or SELV circuit (isolated from MAINS by double insulation)
Leakage current 500 VAC for 1 minute (between DC24V terminal and FG terminal)
Power consumption*2 8.6 W (Max)*3
Backup battery 3V lithium battery CR2032 × 1
Backup battery life About 3 years or more at 25oC
(subject to operation temperature and condition)
Operation temperature 0oC to 50oC (32oF to 122oF)
Storage temperature -20oC to +60oC (-4oF to 140oF)
Operating environment 10% - 90% RH [0oC - 40oC], 10% - 55% RH [41oC - 50oC];
pollution degree: 2
Vibration resistance Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz
with amplitude 3.5 mm; 8.3 Hz - 150 Hz with amplitude 1G
Shock resistance Conforms to IEC60068-2-27:
11 ms, 15 G Peak, in X, Y, Z directions each for 6 times
Dimension
(W) x (H) x (D) mm 215 x 161 x 35.5
Mounting dimension
(W) x (H) mm 196.9 x 142.9
Weight Approx. 700 g
Note:
1. The half-life of the backlight is defined as the maximum luminance being reduced by 50% when the
maximum drive current is supplied to the HMI. The life of LED backlight shown here is estimated at the
room temperature of 25oC with ambient humidity.
2. The withstand voltage of the isolated power circuit is 1500V peak for 1 minute.
3. The HMI power consumption is the power consumed when the HMI is not connecting with other
peripheral devices. To ensure normal operation of the HMI, the recommended capacity of the power
supply is 1.5 to 2 times of the specified power consumption.
4. Isolated power supply is recommended.
5. For DOPSoft programming software for the DOP-100 series and the user manual, you can download
them at http://www.delta.com.tw/ia.
6. The DOP-100 series can be used with other industrial automation equipment. Please read through this
sheet carefully and install the product according to the instructions to avoid danger.
Pobrano z: https://panele-hmi.pl/panel-hmi-7-delta-electronics-dop-107bv

Other manuals for DOP-107BV

1

Other Delta Monitor manuals

Delta VMT-221IP User manual

Delta

Delta VMT-221IP User manual

Delta IIYAMA-E2483HSU-B5 24 " User manual

Delta

Delta IIYAMA-E2483HSU-B5 24 " User manual

Delta DOP-107H Series User manual

Delta

Delta DOP-107H Series User manual

Delta DOP-103BQ User manual

Delta

Delta DOP-103BQ User manual

Delta UNOlite User manual

Delta

Delta UNOlite User manual

Delta VMT-271 User manual

Delta

Delta VMT-271 User manual

Delta IIYAMA-X2783HSU-B3 User manual

Delta

Delta IIYAMA-X2783HSU-B3 User manual

Delta uno next User manual

Delta

Delta uno next User manual

Delta Vivitek NovoDisplay DK430 User manual

Delta

Delta Vivitek NovoDisplay DK430 User manual

Delta Vivitek NovoTouch EK650i User manual

Delta

Delta Vivitek NovoTouch EK650i User manual

Delta VMT-173 User manual

Delta

Delta VMT-173 User manual

Delta DOP-107EV User manual

Delta

Delta DOP-107EV User manual

Delta PPM R1E Installation manual

Delta

Delta PPM R1E Installation manual

Delta DOP-110CS User manual

Delta

Delta DOP-110CS User manual

Delta TP70P User manual

Delta

Delta TP70P User manual

Delta DOP-103BQ User manual

Delta

Delta DOP-103BQ User manual

Delta TV-908A User manual

Delta

Delta TV-908A User manual

Delta UNO-C07X011 User manual

Delta

Delta UNO-C07X011 User manual

Delta DOP-100 Series User manual

Delta

Delta DOP-100 Series User manual

Delta Vivitek NovoTouch EK860i User manual

Delta

Delta Vivitek NovoTouch EK860i User manual

Delta R3E User manual

Delta

Delta R3E User manual

Popular Monitor manuals by other brands

Sony SDM-S51 Specifications

Sony

Sony SDM-S51 Specifications

LG W1953SE user guide

LG

LG W1953SE user guide

Furuno TZT19F installation manual

Furuno

Furuno TZT19F installation manual

Mermaid ventura 150 TFT x4 user manual

Mermaid

Mermaid ventura 150 TFT x4 user manual

ViewSonic GA655 user guide

ViewSonic

ViewSonic GA655 user guide

Avalue Technology IPM-21 Quick reference guide

Avalue Technology

Avalue Technology IPM-21 Quick reference guide

NEC XP21 - MultiSync - 21" CRT Display user manual

NEC

NEC XP21 - MultiSync - 21" CRT Display user manual

Impax 2000 Guide

Impax

Impax 2000 Guide

HP w19 - Widescreen LCD Monitor Service manual

HP

HP w19 - Widescreen LCD Monitor Service manual

ViewSonic VA2251m-LED user guide

ViewSonic

ViewSonic VA2251m-LED user guide

Asus VA229NR user guide

Asus

Asus VA229NR user guide

HP f2304 user guide

HP

HP f2304 user guide

Iiyama ProLite X436S user manual

Iiyama

Iiyama ProLite X436S user manual

Westinghouse L1916HW - 19" LCD Monitor user manual

Westinghouse

Westinghouse L1916HW - 19" LCD Monitor user manual

EVBIKE C965 installation manual

EVBIKE

EVBIKE C965 installation manual

LG IPS236VX owner's manual

LG

LG IPS236VX owner's manual

Dynaudio BM5A MKll user manual

Dynaudio

Dynaudio BM5A MKll user manual

Jedia JMU-307B operating instructions

Jedia

Jedia JMU-307B operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.