1. Safety Instructions
• To ensure sucient convection cooling, always maintain a safety distance of ≥ 20mm
from all ventilated surfaces while the device is in operation.
• The device is not recommended to be placed on low thermal conductive surface, for
example, plastics.
• Note that the enclosure of the device can become very hot depending on the ambient
temperature and load of the power supply. Do not touch the device while it is in
operation or immediately after power is turned OFF. Risk of burning!
• Do not touch the terminals while power is being supplied. Risk of electric shock.
• Prevent any foreign metal, particles or conductors to enter the device through the
openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product
failure
• Warning: When connecting the device, secure Earth connection before connecting L
and N. When disconnecting the device, remove L and N connections before removing
the Earth connection.
• Nominal input voltage: 100-240Vac or 125-250Vdc
Voltage range: 90-264Vac or 120-375Vdc
2. Device Descriptions
Refer to Fig. 1.:
䐟Input & Output terminal block connector
䐠DC voltage adjustment potentiometer
䐡DC OK control LED (Green)
3. Installation of the Device
Refer to Fig. 2.:
䑵Mounting holes for power supply assembly onto the mounting surface. The power
supply shall be mounted on minimum 2 mounting holes using M3 screw minimum
5mm length.
䑶This surface belongs to customer’s end system or panel where the power supply is
mounted.
䑷Connector
• Use exible cable (stranded or solid) with the following sizes:
• The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping
length should not exceed 0.275” or 7mm (Refer to Fig. 3).
4. Installation of Mounting Accessories
Refer to Fig. 4.:
• Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a safety
distance between the screw and internal components.
• Recommended mounting tightening torque: 4~8 Kgf.cm.
REV.01
Fig. 1. Device Descriptions
PMC-05V035W1AA (Standard Connector) PMC-05V035W1AJ (IP20 Connector)
Fig. 3. Wire Type Fig. 4. Mounting Screw
Lug Stripped wire
Mounting
accessories
Mounting
screw
Chassis of
the device
6mm max.
7 mm
Fig. 2. Mounting Orientation
Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal)
PMC-05V035W1AA PMC-05V035W1AJ
AWG 20-14 AWG 20-12
Top Surfac
entilated Surface
ase Surface
1
2
3
Top Surfac
entilated Surface
ase Surface
1
2
3
B
C
A
B
A
C
A
C
B