Instructions
Intended Use
This device is intended for medical pur-
poses to illuminate body surfaces. It is
used for non-invasive visual examination
of intact skin.
This battery-operated product is de-
signed for external examination only
within professional healthcare facilities
by medical professionals.
Check the correct operation of the device
before use! Do not use the device if there
are visible signs of damage.
CAUTION: Do not look directly into the
LED light. Patients must close their eyes
during examinations.
In case of a serious incident with the use
of this device, notify DermLite immedi-
ately and, if required by local regulations,
your national health authority.
CAUTION: Do not use the device in 󰘰re
or explosive risk area (e.g. oxygen-rich
environment).
WARNING: This product can expose you
to chemicals including methylene chlo-
ride and hexavalent chromium, which are
known to the State of California to cause
cancer or reproductive toxicity. For more
information go to www.P65Warnings.
ca.gov.
Electromagnetic Compatibility
This device complies with the EMC
Emissions and Immunity level require-
ments of the standard IEC 60601-1-
2:2014. The emission characteristics of
this equipment make it suitable for use in
professional healthcare environment as
well as residential environment (CISPR
11 Class B). This equipment o󰘯ers ade-
quate protection to radio communication
service. In the rare event of interference
to the radio communication service, the
user might need to take mitigation mea-
sures, such as relocating or re-orienting
equipment.
WARNING: Use of this equipment adja-
cent to or stacked with other equipment
should be avoided because it could re-
sult in improper operation. If such use is
necessary, this equipment and the other
equipment should be observed to verify
that they are operating normally.
WARNING: Use of accessories other
than those provided by the manufac-
turer of this equipment could result in
increased electromagnetic emissions or
decreased electromagnetic immunity of
this equipment and result in improper
operation.
WARNING: Portable RF transmitters
should be used no closer than 30 cm (12
inches) to any part of the device. Other-
wise, degradation of the performance of
this equipment could result.
IMPORTANT: Before initial use, please
charge the internal lithium ion battery.
See “Battery and Charging” for details.
DermLite Foto X is a polarized and
non-polarized dermatoscope designed
for use with a wide range of cameras and
mobile devices.
IceCap®
To support your infection control mea-
sures, snap one of the included dis-
posable IceCaps (IC) over the installed
faceplate (FP). To remove and dispose,
simply pull it o󰘯.
Foto X may be attached to many camer-
as or smartphones via either a magnetic
or purely threaded connection. For use
with MagnetiConnect® adapters (sold
separately), screw the Ring Adapter
(RA) onto the 37 mm thread (37). To
create a threaded connection with your
camera, remove the Ring Adapter (RA)
and thread the Foto X onto a compatible
camera or threaded camera adapter*.
Place the unit onto the skin, then push
the Power button (P) to activate the
light. Tapping the power button toggles
between polarized and non-polarized
light. Move between four brightness
levels via the Brightness Buttons (BB).
To adjust focus, turn the Spacer (S) as
needed; aligning the Focus Marks (FM)
creates the ideal focal distance for most
photography.
To turn o󰘯 your DermLite, push and
hold the Power button (P) for about one
second; the unit turns o󰘯 automatically
after 3 minutes.
*Note that many cameras require the
use of an additional adapter made by the
camera manufacturer or a photography
supply company.
Removing the Spacer
The Spacer (S) may be removed by
turning it counter-clockwise past a slight
resistance. When reattaching, make sure
its three small protrusions match up with
the Bayonet Slot (BS).
Removing the Faceplate
The Faceplate (FP) may simply be pulled
o󰘯 the Spacer (S) by grabbing it at the
󰘰ngernail notches.
Battery and Charging
CAUTION: This device uses a special
3.7V 360 mAh (2pcs) lithium ion bat-
tery, which can only be purchased from
DermLite or from an authorized DermLite
dealer. Do not under any circumstances
use another battery other than the one
designed for this unit.
This device is equipped with a four-level
Charge Indicator (CI). When the unit
is turned on and fully charged, all four
LEDs light up. When less than 75% of
battery life remains, three LEDs are illu-
minated. If more than half the battery is
drained, two LEDs are on, while a single
LED indicates that less than 25% of
battery capacity remains. To charge your
device, connect the supplied USB-C to
USB cable to the Charging Port (CP) and
any IEC 60950-1 compliant (5V) USB
port. The Charge Indicator (CI) pulses
to indicate charging, with the number of
pulsing LEDs corresponding with charge
level. When charging is complete, all four
indicator LEDs illuminate. After years
of use, you may wish to re-place the
battery, which is only available directly
from DermLite or an authorized DermLite
dealer. To change the battery, contact
DermLite or your local DermLite dealer.
Troubleshooting
Please check www.dermlite.com for the
most current troubleshooting information.
If your device requires servicing, visit
www.dermlite.com/service or contact
your local DermLite dealer.
Care and Maintenance
CAUTION: No modi󰘰cation of this equip-
ment is allowed.
Your device is designed for trouble-free
operation. Repairs shall be made only by
quali󰘰ed service personnel.
Cleaning
The exterior of your device, except the
optical parts, may be wiped clean with
isopropyl alcohol (70% vol.) prior to use
on a patient. The lens should be treated
as high-quality photographic equipment
and should be cleaned with standard
lens cleaning equipment and protected
from harmful chemicals. Do not use abra-
sive material on any part of the equip-
ment or immerse the device in liquid. Do
not autoclave.
Warranty: 2 years for parts and labor.
The battery is warranted for 1 year.
Disposal
This device contains electronics and a
lithium-ion battery that must be separat-
ed for disposal and may not be disposed
of with general household waste. Please
observe local disposal regulations.
The DermLite Foto X set includes:
Foto X scope (24 polarized & 8 non-po-
larized LEDs, 30mm 8x lens), USB-A to
USB-C charging cable, 5 IceCaps.
Technical Description
Visit www.dermlite.com/technical or con-
tact your local DermLite dealer.
ENGLISH

Other manuals for Foto X

4

This manual suits for next models

1

Other Dermlite Diagnostic Equipment manuals

Dermlite nailio User manual

Dermlite

Dermlite nailio User manual

Dermlite Foto II Pro User manual

Dermlite

Dermlite Foto II Pro User manual

Dermlite DL200HR User manual

Dermlite

Dermlite DL200HR User manual

Dermlite DL4W User manual

Dermlite

Dermlite DL4W User manual

Dermlite carbon User manual

Dermlite

Dermlite carbon User manual

Popular Diagnostic Equipment manuals by other brands

SKF TMST 3 Instructions for use

SKF

SKF TMST 3 Instructions for use

ECM Imago user manual

ECM

ECM Imago user manual

Sealey AUTO SERVICE VS819 instructions

Sealey

Sealey AUTO SERVICE VS819 instructions

Snap-On ETHOS Edge quick start guide

Snap-On

Snap-On ETHOS Edge quick start guide

Xtool IP819 user manual

Xtool

Xtool IP819 user manual

Autel MaxiLink ML629 Quick reference guide

Autel

Autel MaxiLink ML629 Quick reference guide

Wow iQ4Bike base operating instructions

Wow

Wow iQ4Bike base operating instructions

Medite Total Tissue TKF 22 instruction manual

Medite

Medite Total Tissue TKF 22 instruction manual

Hella Gutmann mega macs 42 SE operating instructions

Hella Gutmann

Hella Gutmann mega macs 42 SE operating instructions

Hella Gutmann mega macs ONE user manual

Hella Gutmann

Hella Gutmann mega macs ONE user manual

Britpart IIDTOOL user manual

Britpart

Britpart IIDTOOL user manual

Topdon T-Ninja Box user manual

Topdon

Topdon T-Ninja Box user manual

Autel MaxiIM IM608 manual

Autel

Autel MaxiIM IM608 manual

Foxwell I80TS manual

Foxwell

Foxwell I80TS manual

Autel MaxiFlash VCMI manual

Autel

Autel MaxiFlash VCMI manual

Motorvac Cool Smoke HP 500-0150 manual

Motorvac

Motorvac Cool Smoke HP 500-0150 manual

Emerson Comfort Alert 543-0038-01 user manual

Emerson

Emerson Comfort Alert 543-0038-01 user manual

BOMTECH A-ONE Lite user manual

BOMTECH

BOMTECH A-ONE Lite user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.