Detex EAX-3500 User manual

INSTALLATION INSTRUCTIONS FOR DETEX EAX-3500 ALARM
Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045
(830)629-2900 / 1-800-729-3839 / Fax (830)620-6711
E-MAIL: dete[email protected] INTERNET: www.detex.com
103140 March 3, 2011
ACTIVATE
TIMED BY-PASS
-3500
RESET
TO ADD ADDITIONAL BY-PASS TIME:
1) Insert key and rotate CCW until green LED turns off.
Release key.
2) Press "ACTIVATE TIMED BY-PASS" button. Light
bar meter illuminates gradually as more By-Pass
time is added.
NOTE: If By-Pass time expires while door is open,
alarm will sound.
TO SILENCE ALARM: Close door, insert and rotate
key CCW.
TO ACTIVATE TIMED BY-PASS:
1) Rotate key counterclockwise (CCW), light bar meter
flashes, then release key.
2) To add By-Pass time, press "ACTIVATE TIMED
BY-PASS" button. Light bar illuminates gradually
as more bypass time is added.
3) Release button. Single green LED turns ON
indicating By-Pass time is set.
4) Remove key and prop open door.
NOTE: Alarm automatically arms and resets if door
closes before time expires.
103140 Page 1

Tapered Collar
p/n 103303
(required/included)
Orient cam
as shown
Fig. 2
MORTISE CYLINDER
REQUIRED
DETEX CYLINDER
p/n 102281-7 (MC-65)
or
p/n 103800-626 (IC7)
Hinged
Panel
Fig. 1
ON
ON
ON
ON
STATUS INDICATOR
DISABLE AUTO REARM
SERVICE BYPASS
DOOR TAMPER SWITCH HAS A SERVICE BYPASS MODE. PULL
SWITCH OUT TO BYPASS DURING UNIT SERVICING & ADJUSTMENT
NORMAL
24VAC INPUT 500mA MAX CURRENT
ALWAYS REMOVE POWER & BATTERY
CONNECTIONS BEFORE SERVICING UNIT
MAX BYPASS TI ME SETTINGS
5 min 10 min 20 min 40 min
OR OR OR
ON
ON
ON
ON
Screw Driver
Safety Glasses
Center Punch
Tape Measure
Hammer
1/4"
NOT REQUIRED
Power Drill
Self-drilling Screws
Sheetmetal Screws
#10 x 1"
#10 x 1"
PPH
PPH
Tools Required
Pencil
Metal Applications
All other Applications
Drill Bit
Fastener Table
Comments
w/ Anchors
EAX-3500 Installation and Usage Guide
Display Board
p/n 103943
Cover Lock & Key
102966
Bracket
p/n 103970
p/n 100783 Cam Assembly
p/n 102680
p/n 102627-15
(2 pls)
Battery Strap
p/n 103963
Modular Cable
p/n 104017-5
12V Battery
p/n 103952
Power Supply Board
p/n 103941
Tamper Switch
p/n 103965
Main Control Board
p/n 103962
Pushbutton Switch
p/n 103957
1. CYLINDER INSTALLATION:
Unlock enclosure and open hinge panel.
To install cylinder (if not already provided) remove cam assembly. Reassemble cylinder into cam assembly as shown in FIG. 2.
TRANSFORMER
p/n103951
(may be sold separately)
Service Kit
Three boards & cable
p/n 104393
+/ -
BATTERY
CONTROL
BOARD
CABLE
POWER
12V AC
24V AC/DC
DISPLAY
BOARD
CABLE
TAMPER
103140 Page 2

DETAIL A
ALWAYS REMOVE POWER & BATTERY
CONNECTIONS BEFORE SERVICING UNIT
24VAC INPUT 500mA MAX CURRENT
SERVICE BYPASS
NORMAL
see step 5 & DETAIL A
OR OR OR
5 min 10 min 20 min 40 min
MAX BYPASS TIME SETTINGS
DOOR TAMPER SWITCH HAS A SERVICE BYPASS MODE. PULL
SWITCH OUT TO BYPASS DURING UNIT SERVICING & ADJUSTMENT
STATUS INDICATOR
DISABLE AUTO REARM
ON ON
ON ON
ON
ON ON
ON
Fig. 3
+/ -
BATTERY
see step 5
CONTROL
BOARD
CABLE
POWER
12V AC
24V AC/DC
DISPLAY
BOARD
CABLE
see step 5
see Detail C
Tamper Switch
Battery
TAMPER
Magswitch
Surface (SK1) and Flush (FK1)
Closed Connection
Door Secure
Magnetic Switch
Flush Mount
MS2049S Option
connections
Magnetic switch
White
Red
(NOT Used)
Black
Magnetic Switch
Surface Mount
DISPLAY BOARD
POWER BOARD
2. MAGNETIC SWITCH INSTALLATION:
Install magnetic contact switch onto door using magnetic switch instructions. For wire requirements, see Manufacture's
Recommendation Chart. Route wires to Exit Alarm location.
Magnetic Contact Switch:
Within 6 feet: 2 conductor cable, 22AWG
20 feet or less: Twisted wire, 20AWG
50 feet or less: Twisted wire, 18AWG
3. TRANSFORMER INSTALLATION:
Connect power wires to the two terminals on the 12VAC to 24VAC transformer. Route wires to Exit Alarm location per applicable
building code(s). DO NOT APPLY POWER AT THIS TIME.
Power Leads from Transformer to Exit Alarm:
20 feet or less: 20AWG
50 feet or less: 18AWG
(MAGNETIC SWITCH may be sold separately)
103140 Page 3

MAX BYPASS TIME SETTINGS:
5 min 10 min 20 min 40 min
DETAIL B
To by-pass for
service, pull post out
Turn access control
key CCW
DETAIL C
TAMPER SWITCH ASSY
OR OR OR
ON ON
ON
ON
ON
ON ON
ON
ONON
4. ENCLOSURE MOUNTING:
Prep surface of wall for mounting Exit Alarm enclosure. Enclosure is designed for all wires to be routed through grommet in rear
hole. Route wires from transformer and magnetic switch through rear hole BEFORE mounting enclosure.
Mount enclosure using mounting screws supplied in hardware kit.
Mounting kit options:
Option 1 - #10 sheet metal screws and #10 plastic anchors
Option 2 - #10 self-drilling screws
NOTE: Enclosure must be earth grounded per NEC requirements.
5. ENCLOSURE INSTALLATION:
Connect magnetic switch wires to PC board located on enclosure door. (See FIG 3 and DETAIL A). Examples shown are for
Detex supplied magnetic switches. Transformers and magnetic switches are required and can be purchased separately.
Connect power wires to the two place terminal block located on lower left corner of power board. Wires are not polarity sensitive
(Fig. 3).
By-Pass time is factory set for 5 minutes. See detail B above for additional By-Pass time options.
To By-Pass for service, extend plunger on tamper switch. (See DETAIL C)
Insert access control key into mortise cylinder on front side of hinged panel.
Install battery (supplied with unit). Remove plastic protectors from the polarity sensitive battery terminals. Alarm will sound if
magnetic switch is not closed and tamper switch plunger is not extended.
Plug wall mounted transformer into wall outlet.
Turn access control key counterclockwise (CCW) 1/4 turn and HOLD for 5 seconds LIGHT BAR METER will turn OFF and
ALARM is reset. Close hinged panel and secure cover lock. Alarm will sound. To silence alarm, rotate access control key CCW.
The single RED LED located next to light meter bar will turn ON indicating device is powered and in the armed mode. Alarm will
sound if magnetic contact switch on door is opened. To silence alarm close magnetic contact switch on door and turn control
key CCW.
103140 Page 4

Symptom:
Key cylinder is loose or sticks out.
Does not arm, key requires high effort to rotate.
Unit in constant alarm mode.
Turning key CCW does not reset alarm.
Unit goes into alarm when service requires
opening the front cover.
Not enough bypass time when set at max.
Goes into alarm when trying to set time.
Unit does not reset once in alarm mode.
Unit chirps every 20 to 30 seconds.
This is a low battery indication.
Probable cause / Fix
Tapered collar not installed.
Hex nut is not secure.
103970 bracket not installed or installed backwards (Flange goes towards the cover).
Incorrect cam on mortise cylinder. Should be Yale type cam.
Self adjusting switch cam mounting screws overly tight.
Magnetic switch too far from magnet or connected to the wrong terminals on the
PWA.
Wrong type of switch contact. Must be closed contact with the door closed and
magnet in correct position.
Pull tamper switch plunger fully out, turn key CCW. Make sure door is closed during
initial opening of the cover.
Change switch positions as needed. See label on inside front cover for options.
Turn key CCW and release. Then press the 'Activate Timed By-Pass' button.
Make sure door is fully closed.
Make sure wiring to the magnetic switch is not damaged or cut.
Check AC power to the device, and that building power is present at the outlet.
Make sure optional plug-in transformer is plugged in and the holding screw installed.
Check for damaged wiring between the transformer and the EAX-3500.
The battery should be replaced every three years
EAX-3500 Troubleshooting
6) TO ACTIVATE TIMED BYPASS:
Rotate key counterclockwise (CCW) until light bar meter flashes, release key.
To add By-Pass time press 'ACTIVATE TIMED BY-PASS' button. Light bar illuminates gradually as more By-Pass time is added.
Release button. Single green LED turns ON indicating By-Pass time is set.
Remove key and prop door open.
NOTE: Alarm automatically arms and resets if door closes before time expires.
7) ADD ADDITIONAL TIMED BYPASS:
Insert key and rotate CCW single green LED turns.
Release key
Press 'ACTIVATE TIMED BY-PASS' button. Light bar illuminates gradually as more By-Pass time is added.
Note: If By-Pass time expires while door is open, alarm will sound.
TO SILENCE ALARM: Close door, insert and rotate key CCW.
8) To service device pull plunger on tamper switch as shown in Detail C. Rotate access control key CCW.
103140 Page 5
Table of contents
Other Detex Security System manuals
Popular Security System manuals by other brands

ADEMCO
ADEMCO VISTA user manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS Y683A101001 Installation and operating manual

MobileHelp
MobileHelp Fall Button user guide

Eden
Eden HA33S Operation and installation manual

Profort
Profort multiGuard DIN9 3G quick guide

iStorage
iStorage diskAshur2 quick start guide